Evaluating the effect of reduced entrance surface dose on neonatal chest imaging using subjective image quality evaluation

被引:12
|
作者
Conradie, Anita [1 ]
Herbst, Charles Petrus [1 ]
机构
[1] Univ Free State, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
来源
关键词
Neonatal; Chest X-rays; Dose; Rabbit phantom; Image quality; INTENSIVE-CARE-UNIT; RADIATION-EXPOSURE; RADIOGRAPHY; OPTIMIZATION; REDUCTION;
D O I
10.1016/j.ejmp.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: As hospitalized neonates are radiosensitive and often require numerous X-rays, institutions should investigate the optimal beam parameter combinations to deliver diagnostically acceptable quality images at the lowest possible entrance surface dose (ESD). Using a subjective approach, this study evaluated the effect of different beam parameter combinations on image quality. Methods and materials: Five rabbits simulated the neonatal chest. The ESD was reduced using a variation of voltage, tube current and filtration. Eight radiology registrars, blinded to the dose parameter information, ranked the digital X-ray images of three anatomical regions from best to worst using a variation of the multiple rank order method. T-tests compared the average values, obtained from the scores assigned by each observer to images acquired at different ESDs, for each region. The calculated intraclass correlation coefficient (ICC) assessed observer agreement. Results: Results showed that a 64% dose reduction was achievable by altering the beam parameters. Large variation among the observers was confirmed by an ICC value <0.5. A 95% confidence interval could not conclude that different ESD values, resulting in a 50-77% dose reduction compared to current practice, would result in different overall observed image quality. This was noted for all three regions indicating that no preference existed towards an image acquired with a specific beam parameter combination. Conclusions: The large variation in observers' opinion of acceptable image quality emphasizes the importance of subjective image quality evaluation in the clinical environment. The rabbit phantom and multiple rank order method are considered appropriate for these evaluations. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 50 条
  • [31] Evaluating parameters for mobile chest computed radiography: Phantoms, image quality and effective dose for three systems
    Rill, L
    Brateman, L
    Arreola, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1374 - 1374
  • [32] Comparison between standard dose and 50%-reduced dose abdominal CT: Effect on image quality
    Prasad, SR
    Blake, MA
    Rhea, JT
    Simeone, JF
    Sahani, DV
    Saini, S
    RADIOLOGY, 2001, 221 : 550 - 550
  • [33] Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients
    Qi, L-P
    Li, Y.
    Tang, L.
    Li, Y-L
    Li, X-T
    Cui, Y.
    Sun, Y-S
    Zhang, X-P
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E906 - E911
  • [34] Dose Reduction and Image Quality Optimization of Pediatric Chest Radiography Using a Tungsten Filter
    Kim, Eunhye
    Muroi, Kenzo
    Koike, Takahisa
    Kim, Jungmin
    BIOENGINEERING-BASEL, 2022, 9 (10):
  • [35] Chest radiography: A comparison of image quality and effective dose using four digital systems
    Pascoal, A
    Lawinski, CP
    Mackenzie, A
    Tabakov, S
    Lewis, CA
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 273 - 277
  • [36] Changing the entrance surface dose and image quality by applying an air mattress to the table commonly used in computed tomography
    Park, J. Y.
    Kim, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 425 - 429
  • [37] Dose and Image Quality Evaluation of a Mobile CT Scanner for Head and Neck Imaging
    Gingold, E.
    Dave, J.
    MEDICAL PHYSICS, 2008, 35 (06) : 2645 - 2646
  • [38] Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT
    Barras, Heloise
    Dunet, Vincent
    Hachulla, Anne-Lise
    Grimm, Jochen
    Beigelman-Aubry, Catherine
    ACTA RADIOLOGICA OPEN, 2016, 5 (08)
  • [39] Reduced radiation dose helical chest CT: Effect on reader evaluation of structures and lung findings
    Mayo, JR
    Kim, KI
    MacDonald, SLS
    Johkoh, T
    Kavanagh, P
    Coxson, HO
    Vedal, S
    RADIOLOGY, 2004, 232 (03) : 749 - 756
  • [40] Evaluation of Radiation Dose and Image Quality using High-Pitch 70-kV Chest CT in Immunosuppressed Patients
    Yel, Ibrahim
    Martin, Simon S.
    Wichmann, Julian L.
    Lenga, Lukas
    Albrecht, Moritz H.
    Bucher, Andreas M.
    Kaltenbach, Benjamin
    Polkowski, Christoph
    Booz, Christian
    Vogl, Thomas J.
    Hammerstingl, Renate Maria
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (02): : 122 - 129