Feasibility of Temporary Biventricular Pacing after Off-Pump Coronary Artery Bypass Grafting in Patients with Reduced Left Ventricular Function

被引:0
|
作者
Wang, Daniel Y. [1 ]
Kelly, Lauren A. [2 ]
Richmond, Marc E. [3 ]
Quinn, T. Alexander [5 ]
Cheng, Bin [4 ]
Spotnitz, Michelle D. [2 ]
Cabreriza, Santos E. [2 ]
Naka, Yoshifumi [2 ]
Stewart, Allan S. [2 ]
Smith, Craig R. [2 ]
Spotnitz, Henry M. [2 ]
机构
[1] Columbia Univ, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Dept Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Pediat, New York, NY 10032 USA
[4] Columbia Univ, Dept Biostat, New York, NY 10032 USA
[5] Univ London Imperial Coll Sci Technol & Med, Harefield Heart Sci Ctr, Natl Heart & Lung Inst, Harefield UB9 6JH, Middx, England
基金
美国国家卫生研究院;
关键词
Arrhythmias; cardiac/therapy; cardiac pacing; artificial/methods; cardiac output; low/therapy; heart failure/therapy; stroke volume; ventricular dysfunction; left/complications/prevention; control; CARDIAC-RESYNCHRONIZATION THERAPY; RANDOMIZED CLINICAL-TRIAL; CHRONIC HEART-FAILURE; EJECTION FRACTION; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; CARDIOPULMONARY BYPASS; SYSTOLIC FUNCTION; CONDUCTION DELAY; SURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In selected patients undergoing cardiac surgery, our research group previously showed that optimized temporary biventricular pacing can increase cardiac output one hour after weaning from cardiopulmonary bypass. Whether pacing is effective after beating-heart surgery is unknown. Accordingly, in this study we examined the feasibility of temporary biventricular pacing after off-pump coronary artery bypass grafting. The effects of optimized pacing on cardiac output were measured with an electromagnetic aortic flow probe at the conclusion of surgery in 5 patients with a preoperative mean left ventricular ejection fraction of 0.26 (range, 0.15-0.35). Atrioventricular (7) and interventricular (9) delay settings were optimized in randomized order. Cardiac output with optimized biventricular pacing was 4.2 +/- 0.7 L/min; in sinus rhythm, it was 3.8 +/- 0.5 L/min. Atrial pacing at a matched heart rate resulted in cardiac output intermediate to that of sinus rhythm and biventricular pacing (4 +/- 0.6 L/min). Optimization of atrioventricular and interventricular delay, in comparison with nominal settings, trended toward increased flow This study shows that temporary biventricular pacing is feasible in patients with preoperative left ventricular dysfunction who are undergoing off-pump coronary artery bypass grafting. Further study of the possible clinical benefits of this intervention is warranted.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [41] Off-pump coronary artery bypass grafting in octogenarians
    Raja, Shahzad G.
    JOURNAL OF THORACIC DISEASE, 2016, 8 : S799 - S807
  • [42] Off-pump coronary artery bypass grafting for everyone?
    Melero Tejedor, Jose Maria
    CIRUGIA CARDIOVASCULAR, 2006, 13 (04): : 263 - 271
  • [43] Anaesthesia for off-pump coronary artery bypass grafting
    Dryden, Leon
    Maccario, Marco
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2018, 19 (06): : 281 - 284
  • [44] Evaluating off-pump coronary artery bypass grafting
    Tourmousoglou, Christos E.
    Lalos, Spiros
    Rokkas, Chris
    STROKE, 2007, 38 (09) : E83 - E83
  • [45] Benefits of off-pump coronary artery bypass grafting
    Hofer, C. K.
    Tavakoli, R.
    Maloigne, M.
    Turina, M.
    Genoni, M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 46 - 47
  • [46] Anaesthesia for off-pump coronary artery bypass grafting
    Dryden, Leon
    Maccario, Marco
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2021, 22 (05): : 286 - 289
  • [47] Stroke in Off-Pump Coronary Artery Bypass Grafting
    Yaku, Hitoshi
    Doi, Kiyoshi
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 16 (04) : 225 - 227
  • [48] Conversion From Off-Pump Coronary Artery Bypass Grafting to On-Pump Coronary Artery Bypass Grafting
    Keeling, Brent
    Thourani, Vinod
    Aliawadi, Gorav
    Kim, Sunghee
    Cyr, Derek
    Badhwar, Vinay
    Jacobs, Jeff
    Brennan, J. Matthew
    Meza, James
    Matsouaka, Roland
    Halkos, Michael E.
    ANNALS OF THORACIC SURGERY, 2017, 104 (04): : 1267 - 1273
  • [49] Off-pump coronary artery bypass grafting in octogenarians
    Tomoki Shimokawa
    Naoki Minato
    Noriko Yamada
    Yuji Takeda
    Yasushi Hisamatsu
    Manabu Itoh
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2003, 51 (3) : 86 - 90
  • [50] Urgent off-pump coronary artery bypass grafting
    Hitoshi Hirose
    Atushi Amano
    Akihito Takahashi
    Shuichirou Takanashi
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (8): : 330 - 337