Feasibility of Temporary Biventricular Pacing after Off-Pump Coronary Artery Bypass Grafting in Patients with Reduced Left Ventricular Function

被引:0
|
作者
Wang, Daniel Y. [1 ]
Kelly, Lauren A. [2 ]
Richmond, Marc E. [3 ]
Quinn, T. Alexander [5 ]
Cheng, Bin [4 ]
Spotnitz, Michelle D. [2 ]
Cabreriza, Santos E. [2 ]
Naka, Yoshifumi [2 ]
Stewart, Allan S. [2 ]
Smith, Craig R. [2 ]
Spotnitz, Henry M. [2 ]
机构
[1] Columbia Univ, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Dept Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Pediat, New York, NY 10032 USA
[4] Columbia Univ, Dept Biostat, New York, NY 10032 USA
[5] Univ London Imperial Coll Sci Technol & Med, Harefield Heart Sci Ctr, Natl Heart & Lung Inst, Harefield UB9 6JH, Middx, England
基金
美国国家卫生研究院;
关键词
Arrhythmias; cardiac/therapy; cardiac pacing; artificial/methods; cardiac output; low/therapy; heart failure/therapy; stroke volume; ventricular dysfunction; left/complications/prevention; control; CARDIAC-RESYNCHRONIZATION THERAPY; RANDOMIZED CLINICAL-TRIAL; CHRONIC HEART-FAILURE; EJECTION FRACTION; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; CARDIOPULMONARY BYPASS; SYSTOLIC FUNCTION; CONDUCTION DELAY; SURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In selected patients undergoing cardiac surgery, our research group previously showed that optimized temporary biventricular pacing can increase cardiac output one hour after weaning from cardiopulmonary bypass. Whether pacing is effective after beating-heart surgery is unknown. Accordingly, in this study we examined the feasibility of temporary biventricular pacing after off-pump coronary artery bypass grafting. The effects of optimized pacing on cardiac output were measured with an electromagnetic aortic flow probe at the conclusion of surgery in 5 patients with a preoperative mean left ventricular ejection fraction of 0.26 (range, 0.15-0.35). Atrioventricular (7) and interventricular (9) delay settings were optimized in randomized order. Cardiac output with optimized biventricular pacing was 4.2 +/- 0.7 L/min; in sinus rhythm, it was 3.8 +/- 0.5 L/min. Atrial pacing at a matched heart rate resulted in cardiac output intermediate to that of sinus rhythm and biventricular pacing (4 +/- 0.6 L/min). Optimization of atrioventricular and interventricular delay, in comparison with nominal settings, trended toward increased flow This study shows that temporary biventricular pacing is feasible in patients with preoperative left ventricular dysfunction who are undergoing off-pump coronary artery bypass grafting. Further study of the possible clinical benefits of this intervention is warranted.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [21] Off-pump coronary artery bypass grafting
    Abu-Omar, Y
    Taggart, DP
    LANCET, 2002, 360 (9329): : 327 - 329
  • [22] Paraplegia After Off-Pump Coronary Artery Bypass Grafting
    Miranda, Matheus
    Hossne, Nelson Americo, Jr.
    de Vilela, Andre Telis
    Buffolo, Enio
    ANNALS OF THORACIC SURGERY, 2014, 97 (01): : 326 - 327
  • [23] Long-Term Outcomes after Off-Pump Coronary Artery Bypass Grafting in Left Ventricular Dysfunction
    Fukui, Toshihiro
    Tabata, Minoru
    Takanashi, Shuichiro
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 (02) : 143 - 149
  • [24] Reduced atrial fibrillation in patients immediately extubated after off-pump coronary artery bypass grafting
    Edgerton, JR
    Herbert, MA
    Prince, SL
    Horswell, JL
    Michelson, L
    Magee, MJ
    Dewey, TM
    Edgerton, ZJ
    Mack, MJ
    ANNALS OF THORACIC SURGERY, 2006, 81 (06): : 2121 - 2127
  • [25] Off-pump coronary artery bypass grafting for elderly patients
    Hirose, H
    Amano, A
    Takahashi, A
    ANNALS OF THORACIC SURGERY, 2001, 72 (06): : 2013 - 2019
  • [26] Off-pump bypass grafting in patients with significant left main coronary artery stenosis
    Saba, D
    Ener, S
    Biçer, M
    Kan Aytaç, II
    Senkaya, I
    Özkan, H
    HEART AND VESSELS, 2004, 19 (01) : 8 - 12
  • [27] Off-pump bypass grafting in patients with significant left main coronary artery stenosis
    Davit Saba
    Serdar Ener
    Murat BıÇer
    İrem İris Kan AytaÇ
    Is¸ık S¸enkaya
    Hayati Özkan
    Heart and Vessels, 2004, 19 : 8 - 12
  • [28] Off-pump minimally invasive coronary artery bypass grafting in patients with left ventricular dysfunction: the lampang experience
    Ushioda, Ryohei
    Hirofuji, Aina
    Yoongtong, Dit
    Sakboon, Boonsap
    Cheewinmethasiri, Jaroen
    Kamiya, Hiroyuki
    Arayawudhikul, Nuttapon
    FRONTIERS IN SURGERY, 2024, 11
  • [29] Early and midterm outcome after off-pump coronary artery bypass grafting in patients with left ventricular dysfunction - Review and commentary
    Toumpoulis
    HEART SURGERY FORUM, 2004, 7 (06): : E545 - E545
  • [30] Influence of pleurotomy on pulmonary function after off-pump coronary artery bypass grafting
    Guizilini, Solange
    Gomes, Walter J.
    Faresin, Sonia M.
    Bolzan, Douglas W.
    Buffolo, Enio
    Carvalho, Antonio C.
    De Paola, Angelo A. V.
    ANNALS OF THORACIC SURGERY, 2007, 84 (03): : 817 - 822