Feasibility of Temporary Biventricular Pacing after Off-Pump Coronary Artery Bypass Grafting in Patients with Reduced Left Ventricular Function

被引:0
|
作者
Wang, Daniel Y. [1 ]
Kelly, Lauren A. [2 ]
Richmond, Marc E. [3 ]
Quinn, T. Alexander [5 ]
Cheng, Bin [4 ]
Spotnitz, Michelle D. [2 ]
Cabreriza, Santos E. [2 ]
Naka, Yoshifumi [2 ]
Stewart, Allan S. [2 ]
Smith, Craig R. [2 ]
Spotnitz, Henry M. [2 ]
机构
[1] Columbia Univ, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Dept Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Pediat, New York, NY 10032 USA
[4] Columbia Univ, Dept Biostat, New York, NY 10032 USA
[5] Univ London Imperial Coll Sci Technol & Med, Harefield Heart Sci Ctr, Natl Heart & Lung Inst, Harefield UB9 6JH, Middx, England
基金
美国国家卫生研究院;
关键词
Arrhythmias; cardiac/therapy; cardiac pacing; artificial/methods; cardiac output; low/therapy; heart failure/therapy; stroke volume; ventricular dysfunction; left/complications/prevention; control; CARDIAC-RESYNCHRONIZATION THERAPY; RANDOMIZED CLINICAL-TRIAL; CHRONIC HEART-FAILURE; EJECTION FRACTION; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; CARDIOPULMONARY BYPASS; SYSTOLIC FUNCTION; CONDUCTION DELAY; SURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In selected patients undergoing cardiac surgery, our research group previously showed that optimized temporary biventricular pacing can increase cardiac output one hour after weaning from cardiopulmonary bypass. Whether pacing is effective after beating-heart surgery is unknown. Accordingly, in this study we examined the feasibility of temporary biventricular pacing after off-pump coronary artery bypass grafting. The effects of optimized pacing on cardiac output were measured with an electromagnetic aortic flow probe at the conclusion of surgery in 5 patients with a preoperative mean left ventricular ejection fraction of 0.26 (range, 0.15-0.35). Atrioventricular (7) and interventricular (9) delay settings were optimized in randomized order. Cardiac output with optimized biventricular pacing was 4.2 +/- 0.7 L/min; in sinus rhythm, it was 3.8 +/- 0.5 L/min. Atrial pacing at a matched heart rate resulted in cardiac output intermediate to that of sinus rhythm and biventricular pacing (4 +/- 0.6 L/min). Optimization of atrioventricular and interventricular delay, in comparison with nominal settings, trended toward increased flow This study shows that temporary biventricular pacing is feasible in patients with preoperative left ventricular dysfunction who are undergoing off-pump coronary artery bypass grafting. Further study of the possible clinical benefits of this intervention is warranted.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [31] Pulmonary function following on and off-pump coronary artery bypass grafting
    Broco, Leticia
    Pasolini, Mariana Grazziotin
    Scapini, Katia Bilhar
    Timm, Barbara
    Posser, Simone Regina
    Franco Rockenbach, Carla Wouters
    de Barcellos, Christiano da Silveira
    Tognon, Alexandre Pereira
    Leguisamo, Camila Pereira
    SCIENTIA MEDICA, 2010, 20 (02) : 149 - 155
  • [32] Results of coronary artery bypass grafting with left ventricular dysfunction (comparison of off-pump versus on-pump)
    Houssa, M. Ait
    Moutakiallah, Y.
    Abdou, A.
    Selkane, C.
    Amahzoune, B.
    Drissi, M.
    Raissouni, M.
    El Bekkali, Y.
    Azendour, H.
    Boulahya, A.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2013, 62 (04): : 241 - 247
  • [33] Coronary artery and graft spasm after off-pump coronary artery bypass grafting
    Fukui T.
    Takanashi S.
    Hosoda Y.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2005, 53 (2): : 109 - 113
  • [34] Off-pump coronary artery bypass surgery in the left ventricular dysfunction
    Eryilmaz, S
    Çorapçioglu, T
    Eren, NT
    Yazicioglu, L
    Kaya, K
    Akalin, H
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (01) : 36 - 40
  • [35] On-pump and off-pump coronary artery bypass grafting
    Shekar, PS
    CIRCULATION, 2006, 113 (04) : E51 - E52
  • [36] Stunned myocardium after off-pump coronary artery bypass grafting
    Grubitzsch, H
    Ansorge, K
    Wollert, HG
    Eckel, L
    ANNALS OF THORACIC SURGERY, 2001, 71 (01): : 352 - 355
  • [37] Outcomes After Off-Pump Reoperative Coronary Artery Bypass Grafting
    Morris, Cullen D.
    Puskas, John D.
    Pusca, Sorin V.
    Lattouf, Omar M.
    Cooper, William A.
    Vassiliades, Thomas A.
    Chen, Edward P.
    Thourani, Vinod H.
    Kilgo, Patrick D.
    Guyton, Robert A.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2007, 2 (01) : 29 - 32
  • [38] Catatonic stupor after off-pump coronary artery bypass grafting
    Chowdhry, Vivek
    Biswal, Suvakanta
    Mohanty, Bipin B.
    Bhuyan, Pradyut
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (04) : 758 - 759
  • [39] Feasibility and efficacy of simultaneous off-pump coronary artery bypass grafting and esophagectomy in elderly patients
    Liu, Ban
    Gu, Chang
    Wang, Yuliang
    Wang, Xiaowei
    Ge, Wen
    Shan, Lingtong
    Wei, Yujian
    Xu, Xiaohan
    Zhang, Yangyang
    ONCOTARGET, 2017, 8 (28) : 46498 - 46505
  • [40] Predictors and Clinical Impacts of Aggravated Left Ventricular Diastolic Dysfunction After Off-Pump Coronary Artery Bypass Grafting
    Lee, Seung Hyun
    Kim, Kwan Wook
    Joo, Hyun-Chel
    Yoo, Kyung-Jong
    Youn, Young-Nam
    CIRCULATION JOURNAL, 2016, 80 (09) : 1937 - +