Feasibility of Temporary Biventricular Pacing after Off-Pump Coronary Artery Bypass Grafting in Patients with Reduced Left Ventricular Function

被引:0
|
作者
Wang, Daniel Y. [1 ]
Kelly, Lauren A. [2 ]
Richmond, Marc E. [3 ]
Quinn, T. Alexander [5 ]
Cheng, Bin [4 ]
Spotnitz, Michelle D. [2 ]
Cabreriza, Santos E. [2 ]
Naka, Yoshifumi [2 ]
Stewart, Allan S. [2 ]
Smith, Craig R. [2 ]
Spotnitz, Henry M. [2 ]
机构
[1] Columbia Univ, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Dept Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Pediat, New York, NY 10032 USA
[4] Columbia Univ, Dept Biostat, New York, NY 10032 USA
[5] Univ London Imperial Coll Sci Technol & Med, Harefield Heart Sci Ctr, Natl Heart & Lung Inst, Harefield UB9 6JH, Middx, England
基金
美国国家卫生研究院;
关键词
Arrhythmias; cardiac/therapy; cardiac pacing; artificial/methods; cardiac output; low/therapy; heart failure/therapy; stroke volume; ventricular dysfunction; left/complications/prevention; control; CARDIAC-RESYNCHRONIZATION THERAPY; RANDOMIZED CLINICAL-TRIAL; CHRONIC HEART-FAILURE; EJECTION FRACTION; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; CARDIOPULMONARY BYPASS; SYSTOLIC FUNCTION; CONDUCTION DELAY; SURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In selected patients undergoing cardiac surgery, our research group previously showed that optimized temporary biventricular pacing can increase cardiac output one hour after weaning from cardiopulmonary bypass. Whether pacing is effective after beating-heart surgery is unknown. Accordingly, in this study we examined the feasibility of temporary biventricular pacing after off-pump coronary artery bypass grafting. The effects of optimized pacing on cardiac output were measured with an electromagnetic aortic flow probe at the conclusion of surgery in 5 patients with a preoperative mean left ventricular ejection fraction of 0.26 (range, 0.15-0.35). Atrioventricular (7) and interventricular (9) delay settings were optimized in randomized order. Cardiac output with optimized biventricular pacing was 4.2 +/- 0.7 L/min; in sinus rhythm, it was 3.8 +/- 0.5 L/min. Atrial pacing at a matched heart rate resulted in cardiac output intermediate to that of sinus rhythm and biventricular pacing (4 +/- 0.6 L/min). Optimization of atrioventricular and interventricular delay, in comparison with nominal settings, trended toward increased flow This study shows that temporary biventricular pacing is feasible in patients with preoperative left ventricular dysfunction who are undergoing off-pump coronary artery bypass grafting. Further study of the possible clinical benefits of this intervention is warranted.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [1] Feasibility of temporary biventricular pacing in patients with reduced left ventricular function after coronary artery bypass grafting
    Eberhardt, Frank
    Hanke, Thorsten
    Heringlake, Mathias
    Massalme, Maximilian S.
    Bechtel, Matthias
    Misfeld, Martin
    Wiegand, Uwe K. H.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S50 - S53
  • [2] Feasibility of temporary biventricular pacing in patients with reduced left ventricular function after coronary artery bypass grafting (vol 30, pg S50, 2007)
    Eberhardt, Frank
    Hanke, Thorsten
    Heringlake, Mathias
    Massalme, Maximilian S.
    Bechtel, Matthias
    Misfeld, Martin
    Wiegand, Uwe K. H.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (11): : 1425 - 1425
  • [3] Off-pump coronary artery bypass grafting in patients with left ventricular dysfunction
    Meharwal, ZS
    Trehan, N
    HEART SURGERY FORUM, 2002, 5 (01): : 41 - 45
  • [4] Off-pump coronary artery-bypass grafting for patients with severely reduced left ventricular function: A justified strategy?
    de Carvalho Lima, Ricardo
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (10) : 3989 - 3989
  • [5] Off-pump coronary artery bypass grafting for patients with severely reduced left ventricular function-A justified strategy?
    de Carvalho Lima, Ricardo
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4617 - 4617
  • [6] Off-pump coronary artery bypass grafting in patients with significant left ventricular dysfunction
    Sajja L.R.
    Mannam G.
    Dandu S.B.R.
    Pathuri S.N.
    Saikiran K.V.S.S.
    Sompalli S.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2008, 24 (2) : 110 - 115
  • [7] Changes in Right Ventricular Function After Off-Pump Coronary Artery Bypass Grafting
    Borde, Deepak
    Joshi, Pooja
    Joshi, Shreedhar
    Asegaonkar, Balaji
    Apsingekar, Pramod
    Khade, Sujeet
    Pande, Swati
    Agrawal, Ashish
    Puranik, Manish
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (03) : 811 - 819
  • [8] Comparison of left ventricular diastolic function after on-pump versus off-pump coronary artery bypass grafting
    Ng, KK
    Popovic, ZB
    Troughton, RW
    Navia, J
    Thomas, JD
    Garcia, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (05): : 647 - 650
  • [9] Left Ventricular Rupture During Off-Pump Coronary Artery Bypass Grafting
    Schwann, Thomas A.
    Omer, Shuab
    Habib, Robert H.
    ANNALS OF THORACIC SURGERY, 2011, 91 (04): : 1261 - 1263
  • [10] Off-pump versus on-pump coronary artery bypass grafting in patients with left ventricular dysfunction
    Ueki, Chikara
    Miyata, Hiroaki
    Motomura, Noboru
    Sakaguchi, Genichi
    Akimoto, Takehide
    Takamoto, Shinichi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (04): : 1092 - 1098