A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations

被引:15
|
作者
Fernandez, Monica A. [1 ]
de Mendoza, Carmen Y. Paez [2 ]
Platt, Jeffrey A. [3 ]
Levon, John A. [4 ]
Hovijitra, Suteera T. [2 ]
Nimmo, Arthur [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Restorat Dent Sci, Div Prosthodont, Gainesville, FL 32610 USA
[2] Indiana Univ, Sch Dent, Dept Restorat Dent, Indianapolis, IN USA
[3] Indiana Univ, Sch Dent, Indianapolis, IN USA
[4] Indiana Univ, Sch Dent, Adv Educ Program Prosthodont, Indianapolis, IN USA
关键词
Implant; impressions; jig; gap; screw test; prosthetic framework; misfit; FIXED PARTIAL DENTURES; MASTER CAST ACCURACY; OSSEOINTEGRATED IMPLANTS; GYPSUM CASTS; PROSTHODONTICS; REPLACEMENT; STONE; DIES;
D O I
10.1111/jopr.12015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A precise transfer of the position and orientation of the antirotational mechanism of an implant to the working cast is particularly important to achieve optimal fit of the final restoration. This study evaluated and compared the accuracy of metal and plastic impression copings for use in a full-arch mandibular edentulous simulation with four implants. Materials and Methods Metal and plastic impression transfer copings for two implant systems, Nobel Biocare Replace and Straumann SynOcta (R), were assessed on a laboratory model to simulate clinical practice. The accuracy of producing stone casts using these plastic and metal impression transfer copings was measured against a standard prosthetic framework consisting of a cast gold bar. A total of 20 casts from the four combinations were obtained. The fit of the framework on the cast was tested by a noncontact surface profilometer, the Proscan 3D 2000 A, using the one-screw test. The effects of implant/system and impression/coping material on gap measurements were analyzed using repeated measures ANOVA. Results The findings of this in vitro study were as follows: plastic copings demonstrated significantly larger average gaps than metal for Straumann (p = 0.001). Plastic and metal copings were not significantly different for Nobel (p = 0.302). Nobel had significantly larger average gaps than Straumann for metal copings (p = 0.003). Nobel had marginally smaller average gaps than Straumann (p = 0.096) for plastic copings. The system-by-screw location interaction was significant as well (p < 0.001), indicating significant differences among the four screw locations, but the location differences were not the same for the two systems. A rank transformation of the data was necessary due to the nonnormal distribution of the gap measurements. No adjustments were made for multiple comparisons. Conclusions The metal impression copings were more accurate than plastic copings when using the Straumann system, and there was no difference between metal and plastic copings for the Nobel Replace system. The system-by-screw location was not conclusive, showing no correlation within each system
引用
收藏
页码:367 / 376
页数:10
相关论文
共 50 条
  • [41] Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression-An In Vitro Study
    Becker, Alexander
    Dirksen, Dieter
    Runte, Christoph
    DENTISTRY JOURNAL, 2023, 11 (09)
  • [42] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [43] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [44] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [45] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    BMC Oral Health, 21
  • [46] Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit
    Papaspyridakos, Panos
    Hirayama, Hiroshi
    Chen, Chun-Jung
    Ho, Chung-Han
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1099 - 1105
  • [47] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Motaz Osman
    Neamat Hassan Abubakr
    Ahmed Suliman
    Hassan Ziada
    International Journal of Implant Dentistry, 6
  • [48] Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study
    Ismail, Ibrahim Ahmed
    Alhajj, Mohammed Nasser
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : E1 - E5
  • [49] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Osman, Motaz
    Abubakr, Neamat Hassan
    Suliman, Ahmed
    Ziada, Hassan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [50] Comparative in vitro study of cementing techniques for implant-supported restorations
    Liang, Tian
    Hu, Xingxue
    Zhu, Lin
    Pan, Xueliang
    Zhou, Yongsheng
    Liu, Jianzhang
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01): : 59 - 66