The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study

被引:3
|
作者
Osman, Motaz [1 ]
Abubakr, Neamat Hassan [2 ]
Suliman, Ahmed [3 ]
Ziada, Hassan [4 ]
机构
[1] Univ Khartoum, Fac Dent, Dept Oral Rehabil, Khartoum, Sudan
[2] Univ Nevada, Sch Dent Med, Biomed Sci, 1001 Shadow Lane,Suite 20, Las Vegas, NV 89106 USA
[3] Univ Khartoum, Dept Oral Maxillofacial Surg, Khartoum, Sudan
[4] Univ Nevada, Clin Sci, Sch Dent Med, Las Vegas, NV 89154 USA
关键词
Implant; Geometrical design; Impression material; ANGULATION;
D O I
10.1186/s40729-020-00256-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim This in vitro study aimed to evaluate the effect of implant impression coping geometrical designs on the accuracy of open and closed impression techniques and in the parallel and nonparallel implant positions. Material and methods Three custom-made acrylic resin models of three tested implant systems (Straumann (R), SIC Invent (R), and Osstem (R)) with diverse coping geometrical designs were evaluated in simulated cases of two parallel and two nonparallel implants. The horizontal and vertical discrepancies were measured and analyzed. Results No statistically significant differences between the two impression techniques in either parallel or nonparallel implants were observed. The high retentive design of the Osstem system showed a statistically significant difference. Conclusion The geometrical design of the impression copings did not affect the accuracy for either the open and closed tray techniques. However, the high retentive coping design of the Osstem implant affected the accuracy in the open tray technique.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Motaz Osman
    Neamat Hassan Abubakr
    Ahmed Suliman
    Hassan Ziada
    [J]. International Journal of Implant Dentistry, 6
  • [2] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [3] Accuracy of Implant Impressions with Different Impression Coping Types and Shapes
    Rashidan, Nayereh
    Alikhasi, Marzieh
    Samadizadeh, Samad
    Beyabanaki, Elahe
    Kharazifard, Mohammad Javad
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 218 - 225
  • [4] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    [J]. IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [5] Effects of Impression Coping Design, Impression Technique, and Dental Undercuts on the Accuracy of Implant Impressions Assessed by 3-Dimensional Optical Scanning: An In Vitro Study
    Sabouhi, Mahmoud
    Bajoghli, Farshad
    Dakhilalian, Mansour
    Beygi, Ali
    Abolhasani, Majid
    [J]. IMPLANT DENTISTRY, 2016, 25 (02) : 238 - 246
  • [6] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    [J]. JOURNAL OF DENTISTRY, 2024, 146
  • [7] Accuracy of impression scanning compared with stone casts of implant impressions
    Matta, Ragai Edward
    Adler, Werner
    Wichmann, Manfred
    Heckmann, Siegfried Martin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 507 - 512
  • [8] Influence of impression technique and material on the accuracy of multiple implant impressions
    Woestmann, Bernd
    Rehmann, Peter
    Balkenhol, Markus
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (04) : 299 - 301
  • [9] ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS
    Kwon, Joo-Hyun
    Son, Yong-Ha
    Han, Chong-Hyun
    Kim, Sunjai
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (06): : 367 - 373
  • [10] Influence of impression material and time on the 3-dimensional accuracy of implant impressions
    Holst, Stefan
    Blatz, Markus B.
    Bergler, Michael
    Goellner, Matthias
    Wichmann, Manfred
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (01): : 67 - 73