Influence of Ocular Stiffness on Intraocular Pressure Estimation Using Goldmann Applanation Tonometry

被引:0
|
作者
Shirane, Masako [1 ]
Kiuchi, Yoshiaki [1 ]
Otani, Keiko [2 ]
Kurita, Yuichi [3 ]
Kaneko, Makoto [4 ]
Takenaka, Joji [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Ophthalmol & Visual Sci, Hiroshima 7348553, Japan
[2] Hiroshima Univ, Res Inst Radiat Biol & Med, Dept Environmetr & Biometr, Hiroshima 7348553, Japan
[3] Hiroshima Univ, Inst Engn, Hiroshima 7398527, Japan
[4] Osaka Univ, Dept Mech Engn, Suita, Osaka 5650871, Japan
关键词
Ocular stiffness; Intraocular pressure estimation; Goldmann applanation tonometry; High-resolution camera; Glaucoma; DYNAMIC CONTOUR TONOMETRY; CORNEAL THICKNESS; BIOMECHANICAL PROPERTIES; RESPONSE ANALYZER; CURVATURE; GLAUCOMA; MODULUS; TENSION; NONCONTACT; ELASTICITY;
D O I
10.5405/jmbe.1381
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate intraocular pressure (IOP) measurement is important for management of glaucoma. Ocular stiffness is considered to be an important biomechanical factor influencing corneal deformation during TOP measurements by a Goldmann applanation tonometer (GAT). The purpose of this study was to investigate how ocular stiffness is related to clinical parameters. Ocular stiffness was defined as the ratio between the change in the force applied to the cornea and the resultant displacement of the corneal apex. Fifty-nine Japanese subjects had their ocular stiffness measured. A GAT was used to apply pressure to the cornea and a high-resolution camera was used to measure corneal apex displacement by photographing the cornea in profile. Multiple regression analyses were used to assess how ocular stiffness is associated with seven factors: TOP measured by the GAT (IOPGAT), radius of curvature of the cornea (R), ocular axial length, anterior chamber depth, central corneal thickness, age, and gender. Ocular stiffness was found to be proportional to the product of (IOPGAT)(0.66) and (R)(0.92); the other factors were not significantly associated with ocular stiffness. For an individual eye, because the value of the radius of corneal curvature was unchanged, ocular stiffness was proportional to (IOPGAT)(0.66). This means that the rate at which ocular stiffness diminishes is greater in the lower, compared to the higher, IOPGAT range. Hence, the rate at which the true TOP diminishes is greater in the lower IOPGAT range because the true IOP is considered to be the primary factor influencing ocular stiffness. This suggests that, in patients with lower IOPGAT, the change of true IOP should become progressively greater than the value indicated by IOPGAT. This result allows improved evaluation of treatment effectiveness in normal-tension glaucoma patients.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [21] Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
    Gungor, Sirel G.
    Akman, Ahmet
    Yazici, Ayse C.
    JOURNAL OF GLAUCOMA, 2015, 24 (06) : 438 - 441
  • [22] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [23] Intraocular pressure difference in goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients
    dos Santos, MG
    Makk, S
    Berghold, A
    Eckhardt, M
    Haas, A
    OPHTHALMOLOGY, 1998, 105 (12) : 2260 - 2263
  • [24] A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry
    Popovich, KS
    Shields, MB
    JOURNAL OF GLAUCOMA, 1997, 6 (01) : 44 - 46
  • [25] Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry
    Li, Yuehua
    Shi, Jingming
    Duan, Xuanchu
    Fan, Fang
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (12) : 1765 - 1770
  • [26] Mask-induced Artifact Impacts Intraocular Pressure Measurement Using Goldmann Applanation Tonometry
    Davanian, Arash M.
    Donahue, Sean P.
    Mogil, Rachel S.
    Groth, Sylvia L.
    JOURNAL OF GLAUCOMA, 2021, 30 (03) : E47 - E49
  • [27] Effect of Mask Mandates on the Intraocular Pressure Measured via Goldmann Applanation Tonometry
    Choi, Woo Seok
    Lee, Chang Hoon
    Lee, Chong Eun
    Seo, Sam
    Lee, Kyoo Won
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (01): : 44 - 50
  • [28] Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry
    Yuehua Li
    Jingming Shi
    Xuanchu Duan
    Fang Fan
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1765 - 1770
  • [29] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Tan, Shaoying
    Yu, Marco
    Baig, Nafees
    Hansapinyo, Linda
    Tham, Clement C.
    SCIENTIFIC REPORTS, 2017, 7
  • [30] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Shaoying Tan
    Marco Yu
    Nafees Baig
    Linda Hansapinyo
    Clement C. Tham
    Scientific Reports, 7