A comparison of mandibular denture base deformation with different impression techniques for implant overdentures

被引:13
|
作者
Elsyad, Moustafa Abdou [1 ]
El-Waseef, Fatma Ahmad [1 ]
Al-Mahdy, Yasmeen Fathy [2 ]
Fouad, Mohammed Mohammed [1 ]
机构
[1] Mansoura Univ, Fac Dent, Eldakahlia, Egypt
[2] Al Azhar Univ, Fac Med Dent, Cairo, Egypt
关键词
deformation; denture base; implant; impression; overdenture; RETAINED OVERDENTURES; STRESS; STRAIN; REINFORCEMENT; MAXILLARY; FRACTURE; TISSUE; MUCOSA;
D O I
10.1111/j.1600-0501.2011.02395.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Materials and methods: Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. Results: The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Conclusion and recommendation: Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [41] Effect of Labial Implant Inclination on the Retention and Stability of Different Resilient Stud Attachments for Mandibular Implant Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Emera, Radwa M. K.
    Ibrahim, Abdullah Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 381 - 389
  • [42] What is the evidence base for the efficacies of different complete denture impression procedures? A critical review
    Carlsson, Gunnar E.
    Ortorp, Anders
    Omar, Ridwaan
    JOURNAL OF DENTISTRY, 2013, 41 (01) : 17 - 23
  • [43] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [44] IMPLANT FRAMEWORK DISPLACEMENTS RESULTING FROM DIFFERENT IMPRESSION TECHNIQUES AND MATERIALS
    RIGSBY, DF
    MISCH, CE
    STRONG, JT
    BIDEZ, MW
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 232 - 232
  • [45] Attachment Systems for Mandibular Single-Implant Overdentures: An In Vitro Retention Force Investigation on Different Designs
    Alsabeeha, Nabeel
    Atieh, Momen
    Swain, Michael V.
    Payne, Alan G. T.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (02) : 160 - 166
  • [46] Mandibular Two-Implant Overdentures: Prosthodontic Maintenance Using Different Loading Protocols and Attachment Systems
    Mackie, Andrew
    Lyons, Karl
    Thomson, W. Murray
    Payne, Alan G. T.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (05) : 405 - 416
  • [47] EFFECT OF IMMERSION IN WATER ON DEFORMATION WITH A VARIETY OF DENTURE BASE MATERIALS AND MANUFACTURING TECHNIQUES
    Huang, Po-Ju
    Wang, Tong-Mei
    Lin, Li-Deh
    Yang, Tsung-Chieh
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (03) : e123 - e135
  • [48] Implant-retained mandibular overdentures: 6-year results of a multicenter clinical trial on 3 different implant systems
    Powers, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (11) : 1269 - 1270
  • [49] Comparison of Prefabricated and Custom-Made Bars Used for Implant-Retained Mandibular Complete Overdentures
    El-Dayem, Mohamed A. Abd
    Assad, Ahmed S.
    Sanad, Mohamed Essam Eldin
    Mogahed, Sayed Abd Al-hady Mahmoud
    IMPLANT DENTISTRY, 2009, 18 (06) : 501 - 511
  • [50] Mandibular residual ridge morphology in relation to complete dentures and implant overdentures-Part I: Predictors for perceived conventional denture stability
    Xia, Yuning
    Ma, Chufan
    Chen, Jihua
    Witter, Dick J.
    Zhang, Qian
    Creugers, Nico H. J.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (01) : 131 - 139