A comparison of mandibular denture base deformation with different impression techniques for implant overdentures

被引:13
|
作者
Elsyad, Moustafa Abdou [1 ]
El-Waseef, Fatma Ahmad [1 ]
Al-Mahdy, Yasmeen Fathy [2 ]
Fouad, Mohammed Mohammed [1 ]
机构
[1] Mansoura Univ, Fac Dent, Eldakahlia, Egypt
[2] Al Azhar Univ, Fac Med Dent, Cairo, Egypt
关键词
deformation; denture base; implant; impression; overdenture; RETAINED OVERDENTURES; STRESS; STRAIN; REINFORCEMENT; MAXILLARY; FRACTURE; TISSUE; MUCOSA;
D O I
10.1111/j.1600-0501.2011.02395.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Materials and methods: Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. Results: The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Conclusion and recommendation: Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [31] Comparisons of chewing difficulty of consumed foods with mandibular conventional dentures and implant-supported overdentures in diabetic denture wearers
    Roumanas, ED
    Garrett, NR
    Hamada, MO
    Kapur, KK
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (06) : 609 - 615
  • [32] Comparative analysis of different implant impression techniques: An In vitro study
    Agnihotri, Radhika R.
    Naik, Saloni
    Vaishnav, Kalpesh
    Shah, Dipti S.
    Joshi, Ravi
    Bhatt, Miloni
    ADVANCES IN HUMAN BIOLOGY, 2023, 13 (05) : 44 - 51
  • [33] Comparison of accuracy of two impression techniques for dental implant.
    Hsu, ML
    Huang, YF
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 461 - 461
  • [34] Comparison of Impression Techniques and Materials for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Chagas Amaral, Angela Libia
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 771 - 776
  • [35] A cost comparison of mandibular two-implant overdenture and conventional denture treatment
    Takanashi, Y
    Penrod, JR
    Lund, JP
    Feine, JS
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2004, 17 (02) : 181 - 186
  • [36] Enhancing Esthetics in a Complete Denture Patient: Optimizing Results With Different Impression Techniques
    Bansod, Akansha V.
    Pisulkar, Sweta G.
    Dahihandekar, Chinmayee
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [37] Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures
    Sadowsky, SJ
    Caputo, AA
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03): : 327 - 334
  • [38] Finite Element Analysis to Compare Complete Denture and Implant-Retained Overdentures With Different Attachment Systems
    Ricardo Barao, Valentim Adelino
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Delben, Juliana Aparecida
    Gomes, Erica Alves
    Capello de Sousa, Edson Antonio
    Rocha, Eduardo Passos
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) : 1066 - 1071
  • [39] Retention of mandibular implant-retained overdentures with two different attachment designs: An in vitro study
    Ramadan, Rania E.
    Mohamed, Faten S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05): : 738.e1 - 738.e6
  • [40] Comparison of shear bond strengths of different types of denture teeth to different denture base resins
    Prpic, Vladimir
    Schauperl, Zdravko
    Glavina, Domagoj
    Catic, Amir
    Cimic, Samir
    JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (06): : 376 - 382