Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study

被引:48
|
作者
Jonas, Jost B. [1 ,2 ]
Wang, Ya Xing [1 ]
Zhang, Qi [1 ]
Liu, Yi [1 ]
Xu, Liang [1 ]
Wei, Wen Bin [3 ]
机构
[1] Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[2] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, D-69115 Heidelberg, Germany
[3] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 08期
关键词
OPTICAL COHERENCE TOMOGRAPHY; SUBFOVEAL CHOROIDAL THICKNESS; ZONE PARAPAPILLARY ATROPHY; OPEN-ANGLE GLAUCOMA; BETA-ZONE; HIGH MYOPIA; FUNDUS PHOTOGRAPHY; RETINAL FEATURES; FOVEA DISTANCE; DISC MARGIN;
D O I
10.1371/journal.pone.0136833
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To assess whether macular Bruch's membrane gets lengthened in axial myopia. Methods Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch's membrane ("MacBMLength") from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables. Results Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 +/- 0.33 mm; range: 3.17-4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 +/- 0.30mm; range: 0.00-2.61mm) was associated (multivariate analysis; correlation coefficient r: 0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95% CI:0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta: 0.28; B: 0.19; 95% CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16 +/- 0.44mm; range: 3.17-5.86mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95% CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95% CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta: 0.42; B: 0.62; 95% CI: 0.44,0.81). Conclusions In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBM-Length was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch's membrane may mostly be independent of axial elongation.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] The role of eye axial length in planning strabismus surgery
    Galantuomo, Maria Silvana
    Fossarello, Maurizio
    Cuccu, Alberto
    Zucca, Ignazio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [44] Axial eye length after retinal detachment surgery
    Vukojevic, N
    Sikic, J
    Curkovic, T
    Juratovac, Z
    Katusic, D
    Saric, B
    Jukic, T
    COLLEGIUM ANTROPOLOGICUM, 2005, 29 : 25 - 27
  • [45] PERIPHERAL CHORIORETINAL LESIONS AND AXIAL LENGTH OF MYOPIC EYE
    KARLIN, DB
    CURTIN, BJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 81 (05) : 625 - 635
  • [46] Measurement of the axial eye length by wavelength tuning interferometry
    Lexer, F
    Hitzenberger, CK
    Kulhavy, M
    Fercher, AF
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 202 - 206
  • [47] Axial length and its associations in a Russian population: The Ural Eye and Medical Study
    Bikbov, Mukharram M.
    Kazakbaeva, Gyulli M.
    Gilmanshin, Timur R.
    Zainullin, Rinat M.
    Arslangareeva, Inga I.
    Salavatova, Venera F.
    Bikbova, Guzel M.
    Panda-Jonas, Songhomitra
    Nikitin, Nikolai A.
    Zaynetdinov, Artur F.
    Nuriev, Ildar F.
    Khikmatullin, Renat I.
    Uzianbaeva, Yulia V.
    Yakupova, Dilya F.
    Aminev, Said K.
    Jonas, Jost B.
    PLOS ONE, 2019, 14 (02):
  • [48] Refractive Error and axial length in Older Chinese Adults:the Pujiang eye study
    Chen, Minjie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [49] Axial length and its associations in a Russian population: The Ural Eye and Medical Study
    Kazakbaeva, Gyulli
    Bikbova, Guzel
    Fayzrakhmanov, Rinat
    Uzyanbaeva, Yulia
    Zainullin, Rinat
    Jonas, Jost B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [50] Association of Bruch’s membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma
    Hideo Nakanishi
    Kenji Suda
    Munemitsu Yoshikawa
    Tadamichi Akagi
    Takanori Kameda
    Hanako Ohashi Ikeda
    Satoshi Yokota
    Yasuo Kurimoto
    Akitaka Tsujikawa
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2018, 256 : 599 - 610