Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study

被引:48
|
作者
Jonas, Jost B. [1 ,2 ]
Wang, Ya Xing [1 ]
Zhang, Qi [1 ]
Liu, Yi [1 ]
Xu, Liang [1 ]
Wei, Wen Bin [3 ]
机构
[1] Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[2] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, D-69115 Heidelberg, Germany
[3] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 08期
关键词
OPTICAL COHERENCE TOMOGRAPHY; SUBFOVEAL CHOROIDAL THICKNESS; ZONE PARAPAPILLARY ATROPHY; OPEN-ANGLE GLAUCOMA; BETA-ZONE; HIGH MYOPIA; FUNDUS PHOTOGRAPHY; RETINAL FEATURES; FOVEA DISTANCE; DISC MARGIN;
D O I
10.1371/journal.pone.0136833
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To assess whether macular Bruch's membrane gets lengthened in axial myopia. Methods Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch's membrane ("MacBMLength") from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables. Results Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 +/- 0.33 mm; range: 3.17-4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 +/- 0.30mm; range: 0.00-2.61mm) was associated (multivariate analysis; correlation coefficient r: 0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95% CI:0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta: 0.28; B: 0.19; 95% CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16 +/- 0.44mm; range: 3.17-5.86mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95% CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95% CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta: 0.42; B: 0.62; 95% CI: 0.44,0.81). Conclusions In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBM-Length was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch's membrane may mostly be independent of axial elongation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Axial Length and Associated Factors in Children: The Shandong Children Eye Study
    Lu, Tai Liang
    Wu, Jian Feng
    Ye, Xiang
    Hu, Yuan Yuan
    Wu, Hui
    Sun, Wei
    Guo, Da Dong
    Wang, Xing Rong
    Bi, Hong Sheng
    Jonas, Jost B.
    OPHTHALMOLOGICA, 2016, 235 (02) : 78 - 86
  • [32] Note on Professor Woodworth's formulae for focal length.
    Southall, JPC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1920, 4 (05) : 245 - 248
  • [33] Results of Ranibizumab Treatment of the Myopic Choroidal Neovascular Membrane according to the Axial Length of the Eye
    Stepanov, Alexandr
    Pencak, Martin
    Nemcansky, Jan
    Matuskova, Veronika
    Stredova, Marketa
    Beran, David
    Studnicka, Jan
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [34] MACULAR LESIONS AND AXIAL LENGTH IN MYOPIC EYES - A CASE-CONTROL STUDY
    AVANZA, P
    MODORATI, G
    PECE, A
    PIERRO, LM
    BRANCATO, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S948 - S948
  • [35] Reexamine the link between retinal layer thickness and cognitive function after correction of axial length: the Beijing Eye Study 2011
    Pan, Zhe
    Li, Zihan
    Xie, Hui
    Huang, Yu
    Xue, Can Can
    Wu, Xiaodong
    Wong, Tien Yin
    Zhang, Chun
    Jonas, Jost B.
    Wang, Ya Xing
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [36] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [37] Hyperopic Refractive Error and Shorter Axial Length Are Associated with Age-Related Macular Degeneration: The Singapore Malay Eye Study
    Lavanya, Raghavan
    Kawasaki, Ryo
    Tay, Wan Ting
    Cheung, Gemmy C. M.
    Mitchell, Paul
    Saw, Seang-Mei
    Aung, Tin
    Wong, Tien Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6247 - 6252
  • [38] Hydrodynamics of ageing Bruch's membrane: Implications for macular disease
    Starita, C
    Hussain, AA
    Pagliarini, S
    Marshall, J
    EXPERIMENTAL EYE RESEARCH, 1996, 62 (05) : 565 - 571
  • [39] AXIAL LENGTH MEASUREMENTS AND FUNDUS CHANGES OF MYOPIC EYE
    CURTIN, BJ
    KARLIN, DB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 71 (01) : 42 - &
  • [40] CHARACTERISTICS OF MULTISTOP MULTIPURPOSE TRAVEL: AN EMPIRICAL STUDY OF TRIP LENGTH.
    O'Kelly, Morton E.
    Miller, Eric J.
    Transportation Research Record, 1984, : 33 - 39