Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study

被引:48
|
作者
Jonas, Jost B. [1 ,2 ]
Wang, Ya Xing [1 ]
Zhang, Qi [1 ]
Liu, Yi [1 ]
Xu, Liang [1 ]
Wei, Wen Bin [3 ]
机构
[1] Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[2] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, D-69115 Heidelberg, Germany
[3] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 08期
关键词
OPTICAL COHERENCE TOMOGRAPHY; SUBFOVEAL CHOROIDAL THICKNESS; ZONE PARAPAPILLARY ATROPHY; OPEN-ANGLE GLAUCOMA; BETA-ZONE; HIGH MYOPIA; FUNDUS PHOTOGRAPHY; RETINAL FEATURES; FOVEA DISTANCE; DISC MARGIN;
D O I
10.1371/journal.pone.0136833
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To assess whether macular Bruch's membrane gets lengthened in axial myopia. Methods Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch's membrane ("MacBMLength") from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables. Results Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 +/- 0.33 mm; range: 3.17-4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 +/- 0.30mm; range: 0.00-2.61mm) was associated (multivariate analysis; correlation coefficient r: 0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95% CI:0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta: 0.28; B: 0.19; 95% CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16 +/- 0.44mm; range: 3.17-5.86mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95% CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95% CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta: 0.42; B: 0.62; 95% CI: 0.44,0.81). Conclusions In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBM-Length was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch's membrane may mostly be independent of axial elongation.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Axial Length in Eyes with Macular Hole Reply
    Zeng, Jing
    Ding, Xiaoyan
    OPHTHALMOLOGY, 2013, 120 (09) : E67 - E68
  • [22] Ocular Axial Length and Diabetic Retinopathy: The Kailuan Eye Study
    Wang, Qian
    Wang, Ya Xing
    Wu, Shou Ling
    Chen, Shuo Hua
    Yan, Yan Ni
    Yang, Mo Chi
    Yang, Jing Yan
    Zhou, Wen Jia
    Chan, Szy Yann
    Zhang, Xiao Hui
    Yang, Xuan
    Lei, Ya Hui
    Qin, Shu Qi
    Chen, Meng Xi
    Jonas, Jost B.
    Wei, Wen Bin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (10) : 3689 - 3695
  • [23] Large coherence length swept source for axial length measurement of the eye
    Chong, Changho
    Suzuki, Takuya
    Totsuka, Kohki
    Morosawa, Atsushi
    Sakai, Tooru
    APPLIED OPTICS, 2009, 48 (10) : D144 - D150
  • [24] ULTRASOUND VELOCITIES FOR AXIAL EYE LENGTH MEASUREMENT
    HOFFER, KJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05): : 554 - 562
  • [25] CALCULATING AXIAL LENGTH IN THE APHAKIC AND THE PSEUDOPHAKIC EYE
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (04): : 413 - 416
  • [26] AXIAL LENGTH OF EYE AND ANTHROPOMETRIC DIMENSIONS FOR INDIANS
    MOHINDRA, I
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1968, 45 (10): : 678 - &
  • [27] SIMPLE METHOD OF DETERMINING AXIAL LENGTH OF EYE
    PERKINS, ES
    HAMMOND, B
    MILLIKEN, AB
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1976, 60 (04) : 266 - 270
  • [28] THE ACCURACY OF ULTRASONIC MEASUREMENT OF THE AXIAL LENGTH OF THE EYE
    BINKHORST, RD
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (05): : 363 - 365
  • [29] Axial Length and Myopic Macular Degeneration Prevalence among Chinese-Americans: The Chinese American Eye Study (CHES)
    Choudhury, Farzana
    Meuer, Stacy M.
    Klein, Ronald
    Torres, Mina
    McKean-Cowdin, Roberta
    Varma, Rohit
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [30] Longitudinal evaluation of upper arch's perimeter and length.
    Robinson, CG
    Vianna, AP
    Lima, EMS
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 261 - 261