Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion

被引:36
|
作者
Sun, Zhenxing [1 ]
Xie, Mingxing [1 ]
Xiang, Feixiang [1 ]
Song, Yue [1 ]
Yu, Cheng [1 ]
Zhang, Yanrong [1 ]
Ramdhany, Sachin [1 ]
Wang, Jing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Ultrasound, Union Hosp, Tongji Med Coll, Wuhan 430022, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
ULTRASOUND ELASTOGRAPHY; BREAST MASSES; PEDIATRIC-PATIENTS; SONOGRAPHY; INFARCTION; LESIONS; US; ELASTICITY; DIAGNOSIS; DISEASE;
D O I
10.1371/journal.pone.0138523
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07+/-9.01kPa vs 22.0 +/-5.10kPa; Emax, 94.07+/-6.53kPa vs 27.87+/-5.78kPa; Emin, 60.73+/-7.84 kPa vs 18.90 +/-4.39kPa; SD, 7.67+/-0.60 kPa vs 2.30+/-0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23+/-0.30 kPa vs 3.97+/-0.95kPa; SD, 1.5+/-0.26kPa vs 0.67+/-0.35kPa, [P< 0.05])and Emin values was lower than those of normal testicles(0.93+/-0.51kPa vs 1.6 +/-0.36kPa; [P< 0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [31] Assessment of Fibrosis during the Development of Fatty Liver in Rabbits using Real-time Shear-wave Elastography
    陆永萍
    韦嘉
    徐丽荣
    汤跃跃
    袁媛
    张勇
    李云燕
    Current Medical Science, 2014, 34 (06) : 921 - 928
  • [32] Accuracy of real-time shear wave elastography in the assessment of normal liver tissue in the guinea pig (cavia porcellus)
    Glinska-Suchocka, K.
    Kubiak, K.
    Spuzak, J.
    Jankowski, M.
    Borusewicz, P.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2017, 20 (01): : 51 - 56
  • [33] Assessment of fibrosis during the development of fatty liver in rabbits using real-time shear-wave elastography
    Lu, Yong-ping
    Wei, Jia
    Xu, Li-rong
    Tang, Yue-yue
    Yuan, Yuan
    Zhang, Yong
    Li, Yun-yan
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (06) : 921 - 928
  • [34] Assessment of fibrosis during the development of fatty liver in rabbits using real-time shear-wave elastography
    Yong-ping Lu
    Jia Wei
    Li-rong Xu
    Yue-yue Tang
    Yuan Yuan
    Yong Zhang
    Yun-yan Li
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 921 - 928
  • [35] How the measurement depth influences the liver stiffness assessment using real-time shear wave elastography (SWE)
    Wang, Cong-zhi
    Xiao, Yang
    Song, Dan
    Ming, Yan
    Zheng, Hai-rong
    Zheng, Jian
    Zeng, Jie
    Huang, Ze-ping
    Zheng, Rong-qin
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 13 - 16
  • [36] Qualitative Assessment of the Diaphragm in the Mechanically Ventilated Critically Ill Using Real-Time Shear Wave Ultrasound Elastography
    Jung, B.
    Flatres, A.
    Aarab, Y.
    Molinari, N.
    Matecki, S.
    Amalric, M.
    Larcher, R.
    Jaber, S.
    Klouche, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [37] Viscoelasticity in trapezius myofascial pain syndrome: quantitative assessment using Real-Time Shear-Wave Elastography
    Hao, Chang-Juan
    Xiao, Wen-Li
    Zhang, Quan-Bin
    Tan, Xiao-Mei
    ANNALS OF MEDICINE, 2023, 55 (02)
  • [38] Shear wave elastography (SWE) is reliable method for testicular spermatogenesis evaluation after torsion
    Zhang, Xiaoying
    Lv, Faqing
    Tang, Jie
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (05): : 7089 - 7097
  • [39] Application of real-time shear wave elastography technology in healthy pediatric hip joints
    Fan Xiangyang
    Wang Ziwei
    Zhou Jingjing
    Di Min
    He Xiao
    BMC Medical Imaging, 25 (1)
  • [40] Diagnostic value of real-time shear wave elastography in children with chronic kidney disease
    Liu, Qin
    Wang, Zhengrong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 77 (03) : 287 - 293