Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion

被引:36
|
作者
Sun, Zhenxing [1 ]
Xie, Mingxing [1 ]
Xiang, Feixiang [1 ]
Song, Yue [1 ]
Yu, Cheng [1 ]
Zhang, Yanrong [1 ]
Ramdhany, Sachin [1 ]
Wang, Jing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Ultrasound, Union Hosp, Tongji Med Coll, Wuhan 430022, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
ULTRASOUND ELASTOGRAPHY; BREAST MASSES; PEDIATRIC-PATIENTS; SONOGRAPHY; INFARCTION; LESIONS; US; ELASTICITY; DIAGNOSIS; DISEASE;
D O I
10.1371/journal.pone.0138523
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07+/-9.01kPa vs 22.0 +/-5.10kPa; Emax, 94.07+/-6.53kPa vs 27.87+/-5.78kPa; Emin, 60.73+/-7.84 kPa vs 18.90 +/-4.39kPa; SD, 7.67+/-0.60 kPa vs 2.30+/-0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23+/-0.30 kPa vs 3.97+/-0.95kPa; SD, 1.5+/-0.26kPa vs 0.67+/-0.35kPa, [P< 0.05])and Emin values was lower than those of normal testicles(0.93+/-0.51kPa vs 1.6 +/-0.36kPa; [P< 0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Determination of Normal Hepatic Elasticity by Using Real-time Shear-wave Elastography
    Suh, Chong Hyun
    Kim, So Yeon
    Kim, Kyoung Won
    Lim, Young-Suk
    Lee, So Jung
    Lee, Moon-Gyu
    Lee, JungBok
    Lee, Sung-Gyu
    Yu, Eunsil
    RADIOLOGY, 2014, 271 (03) : 895 - 900
  • [42] Evaluation of fatty liver fibrosis in rabbits using real-time shear wave elastography
    Lu, Yongping
    Wei, Jia
    Tang, Yueyue
    Yuan, Yuan
    Huang, Yanling
    Zhang, Yong
    Li, Yunyan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 8 (02) : 355 - 362
  • [43] PERFORMANCE OF REAL-TIME STRAIN ELASTOGRAPHY, SHEAR WAVE ELASTOGRAPHY, AND TRANSIENT ELASTOGRAPHY IN ASSESSING SIGNIFICANT FIBROSIS IN CHRONIC VIRAL HEPATITIS
    Ferraioli, G.
    Tinelli, C.
    Dal Bello, B.
    Lissandrin, R.
    Zicchetti, M.
    Filice, C.
    JOURNAL OF HEPATOLOGY, 2012, 56 : S412 - S412
  • [45] Evaluation of varicocele patients using the testicular real-time elastography
    Blgozah, S.
    Shaaban, M.
    Sakr, M. A.
    Salama, N.
    HUMAN REPRODUCTION, 2015, 30 : 139 - 139
  • [46] Assessment of Substantial Liver Fibrosis by Real-time Shear Wave Elastography in Methotrexate-Treated Patients With Rheumatoid Arthritis
    Kim, Tae Yeob
    Kim, Ji Yeoun
    Sohn, Joo Hyun
    Lee, Hye-Soon
    Bang, So-Young
    Kim, Yongsoo
    Kim, Min Yeong
    Jeong, Woo Kyoung
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (09) : 1621 - 1630
  • [47] UTILITY OF TESTICULAR SHEAR-WAVE ELASTOGRAPHY IN THE EVALUATION OF PEDIATRIC PATIENTS WITH KLINEFELTER SYNDROME
    Escott, Megan
    Udaiyar, Abinav
    Wilson, Robert R.
    Hingu, Janmejay
    Kogan, Stanley
    Colaco, Marc
    Schwartz, Marshal
    Hodges, Steve
    Atala, Anthony
    Childs, David
    Sadri-Ardekani, Hooman
    JOURNAL OF UROLOGY, 2024, 211 (05): : E1052 - E1052
  • [48] Real-time elastography for assessment of uterine disorders
    Stoelinga, B.
    Hehenkamp, W. J. K.
    Brolmann, H. A. M.
    Huirne, J. A. F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (02) : 218 - 226
  • [49] Real-time elastography in the assessment of liver fibrosis
    Ferraioli, Giovanna
    Gulizia, Rosario
    Filice, Carlo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : W170 - W170
  • [50] Point shear wave ultrasound elastography with Esaote compared to real-time 2D shear wave elastography with supersonic imagine for the quantification of liver stiffness
    Mulazzani L.
    Salvatore V.
    Ravaioli F.
    Allegretti G.
    Matassoni F.
    Granata R.
    Ferrarini A.
    Stefanescu H.
    Piscaglia F.
    Journal of Ultrasound, 2017, 20 (3) : 213 - 225