Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion

被引:36
|
作者
Sun, Zhenxing [1 ]
Xie, Mingxing [1 ]
Xiang, Feixiang [1 ]
Song, Yue [1 ]
Yu, Cheng [1 ]
Zhang, Yanrong [1 ]
Ramdhany, Sachin [1 ]
Wang, Jing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Ultrasound, Union Hosp, Tongji Med Coll, Wuhan 430022, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
ULTRASOUND ELASTOGRAPHY; BREAST MASSES; PEDIATRIC-PATIENTS; SONOGRAPHY; INFARCTION; LESIONS; US; ELASTICITY; DIAGNOSIS; DISEASE;
D O I
10.1371/journal.pone.0138523
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07+/-9.01kPa vs 22.0 +/-5.10kPa; Emax, 94.07+/-6.53kPa vs 27.87+/-5.78kPa; Emin, 60.73+/-7.84 kPa vs 18.90 +/-4.39kPa; SD, 7.67+/-0.60 kPa vs 2.30+/-0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23+/-0.30 kPa vs 3.97+/-0.95kPa; SD, 1.5+/-0.26kPa vs 0.67+/-0.35kPa, [P< 0.05])and Emin values was lower than those of normal testicles(0.93+/-0.51kPa vs 1.6 +/-0.36kPa; [P< 0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Application value of real-time shear wave elastography in differential diagnosis of testicular torsion
    Xue, Ensheng
    Yu, Yue
    Lin, Lulin
    Li, Zhiyong
    Su, Huanzhong
    [J]. MEDICAL ULTRASONOGRAPHY, 2020, 22 (01) : 45 - 50
  • [2] Utility of Real-Time Shear Wave Elastography in the Assessment of Liver Fibrosis in Patients with Chronic Liver Disease
    Numao, Hiroshi
    Shimaya, Kohji
    Kakuta, Akihisa
    Hasui, Keisuke
    Shibutani, Koichi
    [J]. HEPATOLOGY, 2016, 64 : 213A - 213A
  • [3] Application of real-time shear wave elastography in the assessment of male infertility
    Cui, Jun
    Du, Qiang
    Fu, Wei
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1505 - 1516
  • [4] Real-time tissue elastography for testicular lesion assessment
    Alfredo Goddi
    Andrea Sacchi
    Giovanni Magistretti
    Joan Almolla
    Maurizio Salvadore
    [J]. European Radiology, 2012, 22 : 721 - 730
  • [5] Real-time tissue elastography for testicular lesion assessment
    Goddi, Alfredo
    Sacchi, Andrea
    Magistretti, Giovanni
    Almolla, Joan
    Salvadore, Maurizio
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (04) : 721 - 730
  • [6] Shear wave elastography for the evaluation of testicular salvage after testicular torsion
    Besler, Muhammed Said
    Gokhan, Muhammet Batuhan
    Olcucuoglu, Esin
    Ozdemir, Fatma Ayca Edis
    [J]. ANDROLOGIA, 2022, 54 (11)
  • [7] Application of real-time shear wave elastography in the assessment of torsional cervical dystonia
    Song, Ye
    Zhang, Tian-Jie
    Li, Yuan
    Gao, Yuan
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (04) : 662 - 670
  • [8] Analysis of transient shear wave generation for real-time elastography
    Yagi, S
    Sanuga, A
    Kondo, Y
    Tamura, K
    Sato, A
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1356 - 1359
  • [9] Accuracy of real-time shear wave elastography in the assessment of normal small intestine mucosa in dogs
    Spuzak, J.
    Kubiak, K.
    Glinska-Suchocka, K.
    Jankowski, M.
    Borusewicz, P.
    Kubiak-Nowak, D.
    [J]. POLISH JOURNAL OF VETERINARY SCIENCES, 2019, 22 (03): : 457 - 461
  • [10] Re: Application of Real-Time Shear Wave Elastography in the Assessment of Male Infertility Editorial Comment
    Niederberger, Craig