Application of real-time shear wave elastography in the assessment of torsional cervical dystonia

被引:7
|
作者
Song, Ye [1 ]
Zhang, Tian-Jie [2 ]
Li, Yuan [1 ]
Gao, Yuan [3 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Coll Med Imaging, Zhoupu Hosp, Dept Ultrasonog, Shanghai 201318, Peoples R China
[2] Shanghai Huapukang Pediat Clin, Shanghai 310105, Peoples R China
[3] Tongji Univ, Dept Surg, Tongji Hosp, Shanghai 200065, Peoples R China
关键词
Shear wave elastography; real-time; torsional cervical dystonia; skeletal muscle; shear elastic modulus; PASSIVE MUSCLE-STIFFNESS; QUANTITATIVE ASSESSMENT; BOTULINUM TOXIN; RELIABILITY; CHILDREN; HARDNESS;
D O I
10.21037/qims.2019.04.08
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This study aimed to investigate the value of real-time shear wave elastography (SWE) in the assessment of torsional cervical dystonia (TCD). Methods: Ninety healthy volunteers and 30 TCD patients were recruited, and elastography was performed at musculi sternocleidomastoideus (MSD) and musculi splenius capitis (MSC). Mean shear elastic modulus of right MSD and MSC in healthy controls and bilateral MSD and MSC in TCD patients was determined. The thickness of MSD and MSC of affected muscles was measured in TCD patients. Results: In TCD patients, the mean shear elastic modulus of affected MSD and MSC was significantly higher than that of corresponding normal muscles (P<0.01) and that of controls (P<0.01). The diagnostic threshold was 24.9 kPa for MSD and 25.07 kPa for MSC (for MSD and MSC, the area under ROC was 0.979 and 0.979, with a sensitivity of 90% and 91.3%, and a specificity of 95.6% and 96.7%, respectively). The elastic modulus of neither affected nor normal MSD and MSC was significantly related to age and body mass index (P>0.05). The shear elastic modulus of affected MSD and MSC was positively related to the peak electromyography (r=0.83-0.73, P<0.01). The thickness of affected MSD and MSC was significantly thicker than that of corresponding normal muscles in TCD patients (P<0.01). Conclusions: Real-time SWE can identify the difference in shear elastic modulus of MSD and MSC between the affected and normal side in TCD patients, indicating important diagnostic value in the assessment of muscular status for these patients.
引用
下载
收藏
页码:662 / 670
页数:9
相关论文
共 50 条
  • [1] Application of real-time shear wave elastography in the assessment of male infertility
    Cui, Jun
    Du, Qiang
    Fu, Wei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1505 - 1516
  • [2] Transvaginal Real-time Shear Wave Elastography in the Diagnosis of Cervical Disease
    Liu, Chun
    Li, Ting Ting
    Hu, Ziyue
    Li, Yuan
    Cheng, Xueqing
    Zhu, Yi
    Lu, Man
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (12) : 3173 - 3181
  • [3] Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion
    Sun, Zhenxing
    Xie, Mingxing
    Xiang, Feixiang
    Song, Yue
    Yu, Cheng
    Zhang, Yanrong
    Ramdhany, Sachin
    Wang, Jing
    PLOS ONE, 2015, 10 (09):
  • [4] Re: Application of Real-Time Shear Wave Elastography in the Assessment of Male Infertility Editorial Comment
    Niederberger, Craig
    JOURNAL OF UROLOGY, 2022, 208 (02): : 458 - 458
  • [5] Application of real-time shear wave elastography technology in healthy pediatric hip joints
    Fan Xiangyang
    Wang Ziwei
    Zhou Jingjing
    Di Min
    He Xiao
    BMC Medical Imaging, 25 (1)
  • [6] Application value of real-time shear wave elastography in differential diagnosis of testicular torsion
    Xue, Ensheng
    Yu, Yue
    Lin, Lulin
    Li, Zhiyong
    Su, Huanzhong
    MEDICAL ULTRASONOGRAPHY, 2020, 22 (01) : 45 - 50
  • [7] Analysis of transient shear wave generation for real-time elastography
    Yagi, S
    Sanuga, A
    Kondo, Y
    Tamura, K
    Sato, A
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1356 - 1359
  • [8] Accuracy of real-time shear wave elastography in the assessment of normal small intestine mucosa in dogs
    Spuzak, J.
    Kubiak, K.
    Glinska-Suchocka, K.
    Jankowski, M.
    Borusewicz, P.
    Kubiak-Nowak, D.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2019, 22 (03): : 457 - 461
  • [9] Quantitative Evaluation of the Normal Cervix, Cervical Cancer, and Cervical Precancerous Changes Via Real-Time Shear Wave Elastography
    Guo, Yan-Jing
    Yan, Xiao-Jing
    Zhao, Hai-Xia
    Wen, Xiao-Duo
    Wang, Jing
    Du, Yuan-Yuan
    Wang, Nan
    Yang, Yi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (02) : 345 - 354
  • [10] Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography
    Aubry, Sebastien
    Nueffer, Jean-Philippe
    Tanter, Mickael
    Becce, Fabio
    Vidal, Chrystelle
    Michel, Fabrice
    RADIOLOGY, 2015, 274 (03) : 821 - 829