Electronic portal imaging for dosimetric purposes

被引:0
|
作者
Hansen, VN
机构
[1] Joint, Department of Physics, Royal Marsden NHS Trust and Institute of Cancer Research, Sutton, Surrey
关键词
87.53.10.e; 87.55.08;
D O I
10.1118/1.598060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetric aspects of Electronic Portal Imaging Devices (EPIDs) have been explored. Three models to extract the primary signal from EPIDs have been studied. The first simple model removes the scatter component using a method based on the scatter-to-primary ratio (SPR). This model has several limitations. Two more complex models based on convolution of Pencil Beam Spread Kernels (PBSK) have been studied, one analytical approximation and one iterative solution. Both models based on PBSK were tested on a large set of Monte Carlo generated EPID signals. The primary signal was extracted to within 2% of the true primary signal, using either model, even when SPR was 0.3 in the original image. On the basis of the primary signal of the EPID, generated from any of the above models, two new applications were developed and studied: Transit dosimetry,1 this is verification of the dose delivered using an EPID; and the design of intensity modulated beams (IMB) for tangential breast fields. The IMBs were implemented using either a physical compensator or a set of fields shaped with a multileaf collimator. Dose measurements in an anatomical phantom showed that both implementations gave better dose uniformity than the standard treatment. 1V. N. Hansen, P. M. Evans, and W. Swindell, Med. Phys. 23, 713–721 (1996). © 1997, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1183 / 1183
页数:1
相关论文
共 50 条
  • [21] Dosimetric characteristics and day-to-day performance of an amorphous-silicon type electronic portal imaging device
    Chang, Chiou-Shiung
    Tseng, Yi-Han
    Hwang, Jing-Min
    Shih, Rompin
    Chuang, Keh-Shih
    RADIATION MEASUREMENTS, 2016, 91 : 9 - 14
  • [22] State of the art in electronic portal imaging
    Shalev, S
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 27 - 30
  • [23] Developments in electronic portal imaging systems
    Kirby, M. C.
    Glendinning, A. G.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 : S50 - S65
  • [24] Clinical use of electronic portal imaging
    Herman, MG
    SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) : 157 - 167
  • [25] Monte Carlo computation of dosimetric amorphous silicon electronic portal images
    Siebers, JV
    Kim, JO
    Ko, L
    Keall, PJ
    Mohan, R
    MEDICAL PHYSICS, 2004, 31 (07) : 2135 - 2146
  • [26] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Zhu, Jinhan
    Chen, Lixin
    Chen, Along
    Luo, Guangwen
    Deng, Xiaowu
    Liu, Xiaowei
    RADIATION ONCOLOGY, 2015, 10
  • [27] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Jinhan Zhu
    Lixin Chen
    Along Chen
    Guangwen Luo
    Xiaowu Deng
    Xiaowei Liu
    Radiation Oncology, 10
  • [28] DAILY DOSIMETRIC QUALITY-CONTROL OF THE MM50 RACETRACK MICROTRON USING AN ELECTRONIC PORTAL IMAGING DEVICE
    DIRKX, MLP
    KROONWIJK, M
    DEBOER, JCJ
    HEIJMEN, BJM
    RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) : 55 - 60
  • [29] On-Line Dosimetric Verification of Respiratory Gated Volumetric Modulated Arc Therapy Using the Electronic Portal Imaging Device
    Schaly, B.
    Xhaferllari, I.
    Gaede, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3469 - 3470
  • [30] The use of an electronic portal imaging system to measure portal dose and portal dose profiles
    Parsaei, H
    El-Khatib, E
    Rajapakshe, R
    MEDICAL PHYSICS, 1998, 25 (10) : 1903 - 1909