Electronic portal imaging for dosimetric purposes

被引:0
|
作者
Hansen, VN
机构
[1] Joint, Department of Physics, Royal Marsden NHS Trust and Institute of Cancer Research, Sutton, Surrey
关键词
87.53.10.e; 87.55.08;
D O I
10.1118/1.598060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetric aspects of Electronic Portal Imaging Devices (EPIDs) have been explored. Three models to extract the primary signal from EPIDs have been studied. The first simple model removes the scatter component using a method based on the scatter-to-primary ratio (SPR). This model has several limitations. Two more complex models based on convolution of Pencil Beam Spread Kernels (PBSK) have been studied, one analytical approximation and one iterative solution. Both models based on PBSK were tested on a large set of Monte Carlo generated EPID signals. The primary signal was extracted to within 2% of the true primary signal, using either model, even when SPR was 0.3 in the original image. On the basis of the primary signal of the EPID, generated from any of the above models, two new applications were developed and studied: Transit dosimetry,1 this is verification of the dose delivered using an EPID; and the design of intensity modulated beams (IMB) for tangential breast fields. The IMBs were implemented using either a physical compensator or a set of fields shaped with a multileaf collimator. Dose measurements in an anatomical phantom showed that both implementations gave better dose uniformity than the standard treatment. 1V. N. Hansen, P. M. Evans, and W. Swindell, Med. Phys. 23, 713–721 (1996). © 1997, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1183 / 1183
页数:1
相关论文
共 50 条
  • [41] Electronic portal Imaging using Cerenkov radiation
    Silva, I.
    Pang, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S93 - S93
  • [42] Dosimetry with a fluoroscopic electronic portal imaging device
    Pasma, KL
    MEDICAL PHYSICS, 2000, 27 (02) : 423 - 423
  • [43] Electronic portal imaging in prostate radiation therapy
    Stryker, JA
    Shafer, JD
    Beatty, RE
    RADIOLOGY, 1996, 201 : 776 - 776
  • [44] Patient dose due to electronic portal imaging
    Bezak, E
    Marcu, L
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S58 - S59
  • [45] On the use of electronic portal imaging for treatment verification
    Wong, J
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 269 - 271
  • [46] The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device
    Mohammadi, Mohammad
    Bezak, Eva
    Reich, Paul
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01): : 69 - 84
  • [47] Dosimetric verification of 6 and 18 MV intensity modulated photon beams using a dedicated fluoroscopic electronic portal imaging device (EPID)
    Monti, Angelo F.
    Frigerio, Giovanna
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) : 88 - 96
  • [48] OPTIMIZATION AND EVALUATION OF THE PORTAL DOSIMETRY PROFILE CORRECTION FOR AN ELECTRONIC PORTAL IMAGING DEVICE
    Samsoe, E.
    Sjostrom, D.
    Karlsson, A.
    Behrens, C.
    Van Esch, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S215 - S215
  • [49] A new approach in the design of electronic portal imaging devices for portal dosimetry in radiotherapy
    Badel, J. -N.
    Partouche-Sebban, D.
    Abraham, I.
    Carrie, C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 644 - 653
  • [50] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955