Verification of geometric accuracy at the time of treatment delivery has always been a necessary part of the radiotherapy process. Since the introduction of conformal and intensity-modulated radiotherapy, the consequences of patient positioning errors are more serious. Portal imaging has played a large part in fulfilling the need for improved geometric accuracy. This review examines how portal imaging has progressed through the development and evolution of electronic portal imaging devices (EPIDs). Changes in technology, including the current commercial systems, and how image quality has changed are presented. The clinical usage of EPIDs and the technological innovations being devised for further improvements in image quality and systems are considered. (C) 2006 The British Institute of Radiology.
引用
收藏
页码:S50 / S65
页数:16
相关论文
共 50 条
  • [1] Electronic portal imaging
    vanHerk, M
    Bel, A
    Gilhuijs, KGA
    Lebesque, JV
    vanDalen, A
    vanderVen, P
    Vijlbrief, R
    BULLETIN DU CANCER, 1995, 82 : S601 - S606
  • [2] Phantom for quality control of electronic-portal-imaging-systems
    Röser, A
    Divoux, S
    Rachinskiy, I
    Schilcher, RB
    STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 : 112 - 113
  • [3] Correction of geometrical distortions in video based electronic portal imaging systems
    Hilsebecher, J
    Bortfeld, T
    Schlegel, W
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 275 - 278
  • [4] Electronic portal imaging for dosimetric purposes
    Hansen, VN
    MEDICAL PHYSICS, 1997, 24 (07) : 1183 - 1183
  • [5] State of the art in electronic portal imaging
    Shalev, S
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 27 - 30
  • [6] Clinical use of electronic portal imaging
    Herman, MG
    SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) : 157 - 167
  • [7] MC based dose calculations for verifications based on electronic portal imaging systems
    Lewis, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S4 - S5
  • [9] The use of an electronic portal imaging system to measure portal dose and portal dose profiles
    Parsaei, H
    El-Khatib, E
    Rajapakshe, R
    MEDICAL PHYSICS, 1998, 25 (10) : 1903 - 1909
  • [10] Importance of daily electronic portal imaging in radiotherapy
    Bell, L. J.
    Shakespeare, T. P.
    Willis, A.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (04) : 414 - 418