Study of Head Scatter Factor in 4MV Photon Beam Used in Radiotherapy

被引:1
|
作者
Appasamy, Murugan [1 ,2 ]
Xavier, Sidonia Valas [1 ]
Kuppusamy, Thayalan [1 ]
Velayudham, Ramasubramanian [2 ]
机构
[1] Dr Kamakshi Mem Hosp, Med Phys Div, Chennai 600100, Tamil Nadu, India
[2] VIT Univ, Nucl & Med Phys Div, Sch Adv Sci, Vellore 632014, Tamil Nadu, India
关键词
Head scatter factor (S-c); Phantom scatter factor (S-p); 4; MV; Miniphantom; OUTPUT FACTOR; ELECTRON CONTAMINATION; LINEAR ACCELERATORS; MINI-PHANTOM; RATIO; AIR; CO-60; FIELD;
D O I
10.7785/tcrt.2012.500316
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The 4 MV photon beam offers equal build-up region behavior like Co-60 beam and it plays a major role in head and neck and pediatric radiotherapy. In this study an attempt is made to study the head scatter factor (S-c) for 4 MV photon beam using locally designed PMMA and Brass miniphantoms. The S-c is measured in combination of PMMA miniphantom with 0.6 cc chamber and Brass miniphantom with 0.6 cc and 0.13 cc chambers. The measured S-c is compared with the literature data and it agrees within +/- 1.98%. The study reveals that either 0.13 cc or 0.6 cc chamber with PMMA or Brass phantom materials can be used for S-c measurements in a 4 MV photon beam. The variation of SSD does not alter the head scatter factor: The collimator exchange effect is found to be within 1, and it is less than that of other linear accelerators. It is also found that the presence of internal wedge has significant contribution to head scatter factor. The Phantom scatter factor is also calculated and it agrees within +/- 1% with published data.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [41] Development of an optimum photon beam model for head-and-neck intensity-modulated radiotherapy
    Webster, Gareth J.
    Rowbottom, Carl G.
    Mackay, Ranald I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 129 - 138
  • [42] Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV
    Plaza, Dominika
    Sroka, Lukasz
    Orzechowska, Klaudia
    Slosarek, Krzysztof
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2023, 28 (05) : 654 - 660
  • [43] CARDIAC EVENTS AFTER RADIOTHERAPY OF THE INTERNAL MAMMARY CHAIN BY AN EXCLUSIVE 6 MV PHOTON BEAM: A COHORT FROM EPINAL
    Simon, J. M.
    Renoult, F.
    Admant, P.
    Marchesi, V.
    Noel, A.
    El Hajj, L.
    Levitchi, M.
    Marchal, C.
    Eschwege, F.
    Peiffert, D.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S129 - S129
  • [44] Surface dose measurements in chest wall postmastectomy radiotherapy to achieve optimal dose delivery with 6 MV photon beam
    Lobo, Dilson
    Banerjee, Sourjya
    Srinivas, Challapalli
    Athiyamaan, M. S.
    Reddy, Shreyas
    Sunny, Johan
    Ravichandran, Ramamoorthy
    Kotian, Himani
    Prakash Saxena, P. U.
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 324 - 333
  • [45] Cellular analysis on the radiation induced bystander effects due to bismuth oxide nanoparticles with 6 MV photon beam radiotherapy
    Zainudin, Nur Hamizah Mohd
    Sisin, Noor Nabilah Talik
    Ab Rashid, Raizulnasuha
    Jamil, Amirah
    Anuar, Muhammad Afiq Khairil
    Razak, Khairunisak Abdul
    Abdullah, Reduan
    Rahman, Wan Nordiana
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (03) : 318 - 325
  • [46] Characterization of wedge factors and dose distributions in radiotherapy with symmetric and asymmetric physical wedged beams of 6 MV photon beam
    Zabihzadeh M.
    Fadaei M.
    Hoseini S.M.
    Arvandi S.
    Tahmasbi M.
    Iranian Journal of Medical Physics, 2020, 17 (03) : 213 - 219
  • [47] DETERMINATION OF SCATTER RADIATION PRODUCED BY BEAM-MODIFYING FILTERS IN 4-MV X-RAY-BEAMS
    HUANG, PH
    BJARNGARD, BE
    MEDICAL PHYSICS, 1983, 10 (04) : 546 - 546
  • [48] A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam
    Mesbahi, Asghar
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 55 - 60
  • [49] Study of the dosimetric properties of an unflattened 6-MV photon beam by using the BEAMnrc code
    Kajaria, Ankit
    Sharma, Neeraj
    Sharma, Shiru
    Pradhan, Satyajit
    Mandal, Abhijit
    Aggarwal, Lalit. M.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (04) : 657 - 665
  • [50] Study of the dosimetric properties of an unflattened 6-MV photon beam by using the BEAMnrc code
    Ankit Kajaria
    Neeraj Sharma
    Shiru Sharma
    Satyajit Pradhan
    Abhijit Mandal
    Lalit. M. Aggarwal
    Journal of the Korean Physical Society, 2016, 69 : 657 - 665