Validation of a point-of-care glucometer for use in dairy cows

被引:32
|
作者
Wittrock, J. A. M. [1 ]
Duffield, T. F. [1 ]
LeBlanc, S. J. [1 ]
机构
[1] Univ Guelph, Ontario Vet Coll, Dept Populat Med, Guelph, ON N1G 2W1, Canada
关键词
glucometer; insulin resistance; glucose tolerance test; peripartum; INSULIN-RESISTANCE; GLUCOSE; KETOSIS;
D O I
10.3168/jds.2012-6533
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The purpose of this study was to evaluate the diagnostic performance of a hand-held electronic glucometer (Precision Xtra; Abbott Diabetes Care Inc., Mississauga, ON, Canada) for cow-side use in dairy cattle. This device has been validated for measuring blood concentrations of beta-hydroxybutyrate in dairy cows. This study was designed to assess the accuracy of whole-blood glucose measurements from the glucose meter relative to a reference chemical analyzer in a diagnostic laboratory. Duplicate samples were taken from the same cows at the same time, into blood tubes with either the glycolysis-inhibiting preservative sodium fluoride (NaF) or without preservative. Glucometer readings were taken on whole blood with no preservative, and laboratory measurements were conducted on serum preserved with NaF. Blood samples were collected from cows between 3 wk before and 5 wk after calving, including during a glucose tolerance test conducted 1 wk before expected calving. Passing-Bablok and Bland-Altman data analyses were used to evaluate the performance of the glucometer relative to the laboratory results. A strong correlation was observed in 709 samples from 81 cows between the hand-held meter and serum from samples preserved with NaF (R-2 = 0.95). Overall, 96% of measurements with the glucometer fell within the 95% confidence limits of analysis in the laboratory, although at higher-than-physiologic glucose concentrations (>5.2 mmol/L) the glucometer tended to overestimate. The hand-held glucometer appears suitable for rapid measurement of glucose under field conditions in dairy cattle.
引用
收藏
页码:4514 / 4518
页数:5
相关论文
共 50 条
  • [21] Point-of-Care Ultrasound Use by Primary Care Physicians
    Niblock, Franklin
    Byun, Hoon
    Jabbarpour, Yalda
    JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE, 2021, 34 (04) : 859 - 860
  • [22] Formulation and validation of a predictive model to correct blood glucose concentrations obtained with a veterinary point-of-care glucometer in hemodiluted and hemoconcentrated canine blood samples
    Lane, Selena L.
    Koenig, Amie
    Brainard, Benjamin M.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2015, 246 (03): : 307 - 312
  • [23] Validation of Point-of-Care ultrasound in the diagnosis of a diaphragmatic hernia
    de la Quintana Gordon, F. de Borja
    Oliver-Fornies, P.
    Garcia, M. Martinez
    Centeno-Perez, A.
    Perez, M. Fajardo
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2023, 70 (07): : 404 - 408
  • [24] Developmental validation of a point-of-care, salivary α-amylase biosensor
    Shetty, Vivek
    Zigler, Corwin
    Robles, Theodore F.
    Elashoff, David
    Yamaguchi, Masaki
    PSYCHONEUROENDOCRINOLOGY, 2011, 36 (02) : 193 - 199
  • [25] Validation of the Mission Point-of-care device for haemoglobin measurement
    Louw, Susan
    Mayne, Anthony Leland Hamilton
    Wan, Yuen On
    Mayne, Elizabeth
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (01) : E9 - E11
  • [26] Pregnancy evaluation with a point-of-care pregnancy test in dairy cattle
    Szelenyi, Zoltan
    Lipthay, Ildiko
    Santa, Attila
    Lenart, Lea
    Repasi, Atilla
    Szenci, Otto
    THERIOGENOLOGY, 2024, 214 : 201 - 205
  • [27] Comparison of determination of β-carotene concentration in blood of dairy cows with the point-of-care assay iCheck™ Carotene and the reference method HPLC
    Hamann, N.
    Hye, N.
    Blessing, A.
    Burmeister, J.
    Drillich, M.
    WIENER TIERARZTLICHE MONATSSCHRIFT, 2019, 106 (7-8): : 153 - 159
  • [28] Comparison of glucose concentrations in canine whole blood, plasma, and serum measured with a veterinary point-of-care glucometer
    Suchowersky, Natalie D.
    Carlson, Elizabeth A.
    Lee, Hollie P.
    Behrend, Ellen N.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2021, 33 (04) : 695 - 702
  • [29] Development of a "Dual Gates" Locked, Target-Triggered Nanodevice for Point-of-Care Testing with a Glucometer Readout
    Wang, Lumin
    Zhu, Fawei
    Chen, Miao
    Xiong, Yu
    Zhu, Yuqiu
    Xie, Siqi
    Liu, Qi
    Yang, Hua
    Chen, Xiaoqing
    ACS SENSORS, 2019, 4 (04) : 968 - 976
  • [30] Perioperative Point-of-Care Ultrasound Use by Anesthesiologists
    Naji, Abdullah
    Chappidi, Monica
    Ahmed, Abdelwahab
    Monga, Aaron
    Sanders, Joseph
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (05)