Validation of a point-of-care glucometer for use in dairy cows

被引:32
|
作者
Wittrock, J. A. M. [1 ]
Duffield, T. F. [1 ]
LeBlanc, S. J. [1 ]
机构
[1] Univ Guelph, Ontario Vet Coll, Dept Populat Med, Guelph, ON N1G 2W1, Canada
关键词
glucometer; insulin resistance; glucose tolerance test; peripartum; INSULIN-RESISTANCE; GLUCOSE; KETOSIS;
D O I
10.3168/jds.2012-6533
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The purpose of this study was to evaluate the diagnostic performance of a hand-held electronic glucometer (Precision Xtra; Abbott Diabetes Care Inc., Mississauga, ON, Canada) for cow-side use in dairy cattle. This device has been validated for measuring blood concentrations of beta-hydroxybutyrate in dairy cows. This study was designed to assess the accuracy of whole-blood glucose measurements from the glucose meter relative to a reference chemical analyzer in a diagnostic laboratory. Duplicate samples were taken from the same cows at the same time, into blood tubes with either the glycolysis-inhibiting preservative sodium fluoride (NaF) or without preservative. Glucometer readings were taken on whole blood with no preservative, and laboratory measurements were conducted on serum preserved with NaF. Blood samples were collected from cows between 3 wk before and 5 wk after calving, including during a glucose tolerance test conducted 1 wk before expected calving. Passing-Bablok and Bland-Altman data analyses were used to evaluate the performance of the glucometer relative to the laboratory results. A strong correlation was observed in 709 samples from 81 cows between the hand-held meter and serum from samples preserved with NaF (R-2 = 0.95). Overall, 96% of measurements with the glucometer fell within the 95% confidence limits of analysis in the laboratory, although at higher-than-physiologic glucose concentrations (>5.2 mmol/L) the glucometer tended to overestimate. The hand-held glucometer appears suitable for rapid measurement of glucose under field conditions in dairy cattle.
引用
收藏
页码:4514 / 4518
页数:5
相关论文
共 50 条
  • [31] Use of Point-of-Care Ultrasound to Assess CKD
    Reisinger, Nathaniel
    Koratala, Abhilash
    Goral, Simin
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 77 (01)
  • [32] Use of point-of-care testing for plasma therapy
    Goodnough, Lawrence Tim
    Hill, Charles C.
    TRANSFUSION, 2012, 52 : 56S - 64S
  • [33] Perioperative Point-of-Care Ultrasound Use by Anesthesiologists
    Naji, Abdullah
    ANESTHESIA AND ANALGESIA, 2022, 134 : 998 - 999
  • [34] Prehospital point-of-care ultrasound use by the military
    Ward, David I.
    EMERGENCY MEDICINE AUSTRALASIA, 2007, 19 (03) : 282 - 282
  • [35] Editorial: Point-of-care diagnostics for veterinary use
    Chander, Yogesh
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [36] A veterinary-calibrated point-of-care glucometer accurately measures blood glucose concentration in dogs and cats
    Cammarano, Kellie
    Carney, Patrick C.
    Rose, Hailey E.
    Merkhassine, Michael
    Ippolito, Elizabeth
    Arsenault, Anne
    Plotsker, Noah M.
    Loftus, John P.
    Kowalczyk, Marcin
    Prieto, Jennifer M. B.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2024, 85 (09)
  • [37] Validation of the Use of a Point-of-Care Device in Monitoring the International Normalised Ratio in Postoperative Cardiac Patients
    Wee, Hide E.
    Sin, Kenny Y. K.
    Chiang, Patsy
    Guo, Kenneth W. Q.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2016, 45 (09) : 424 - 426
  • [38] Nurse Practitioner Use of Point-of-Care Ultrasound in Critical Care
    Brunhoeber, L. Alexandra
    King, Joan
    Davis, Sarah
    Witherspoon, Briana
    JNP-JOURNAL FOR NURSE PRACTITIONERS, 2018, 14 (05): : 383 - 388
  • [39] Use of point-of-care ultrasound by a critical care retrieval team
    Mazur, Stefan M.
    Pearce, Andrew
    Alfred, Sam
    Sharley, Peter
    EMERGENCY MEDICINE AUSTRALASIA, 2007, 19 (06) : 547 - 552
  • [40] Use of point-of-care glucose meters in the intensive care units
    Roman, A.
    Preiser, J. -C.
    REANIMATION, 2011, 20 (04): : 350 - 353