4DCT Simulation With Synchronized Contrast Injection in Liver SBRT Patients

被引:11
|
作者
Helou, Joelle [1 ,2 ]
Karotki, Aliaksandr [3 ]
Milot, Laurent [4 ]
Chu, William [1 ,2 ]
Erler, Darby [1 ]
Chung, Hans T. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Radiat Oncol, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Med Phys, Toronto, ON M4N 3M5, Canada
[4] Sunnybrook Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
liver; stereotactic body radiation therapy; 4DCT; contrast; simulation; RADIATION-THERAPY; METASTASES; DELINEATION; RESECTION; MOTION;
D O I
10.1177/1533034615572341
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Purpose: Delivering stereotactic body radiotherapy for liver metastases remains a challenge because of respiratory motion and poor visibility without intravenous contrast. The purpose of this article is to describe a novel and simple computed tomography (CT) simulation process of integrating timed intravenous contrast that could overcome the uncertainty of target delineation. Methods and Results: The simulation involves two 4-dimensional CT (4DCT) scans. The first scan only encompasses the immediate region of the tumor and surrounding tissue, which reduces the 4DCT scan time so that it can be optimally timed with intravenous contrast injection. The second 4DCT scan covers a larger volume and is used as the primary CT data set for dose calculation, as well as patient setup verification on the treatment unit. The combination of the two 4DCT scans allows us to optimally visualize liver metastases over all phases of the breathing cycle while simultaneously acquiring a long enough 4DCT data set that is suitable for planning and patient setup verification. Conclusion: This simulation technique allows for a better target definition when treating liver metastases, without being invasive.
引用
收藏
页码:55 / 59
页数:5
相关论文
共 50 条
  • [21] A Phantom Study to Determine the Dosimetric Effects of the Primary Image Choice Used for SBRT Radiotherapy Planning Following 4DCT Simulation
    Forbang, R. Teboh
    Lewis, B.
    Ndlovu, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E613 - E613
  • [22] 4DCT and VMAT for lung patients with irregular breathing
    Caines, Rhydian
    Sisson, Naomi K.
    Rowbottom, Carl G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):
  • [23] Pre-Treatment 4DCT Fiducial Marker Combination Selection for Robotic Lung SBRT
    Belcher, W.
    Ju, A.
    Jung, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] Evaluation of 4DCT and Soft-Tissue Registration in the Clinical Process for SBRT Patient Treatment
    Smith, C.
    Gulam, M.
    Hammoud, R.
    Nurushev, T.
    Ajlouni, M.
    Chetty, I. J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [25] Individualized breathing trace quality assurance for lung radiotherapy patients undergoing 4DCT simulation
    Rijken, James
    Hu, Yunfei
    Hiscoke, Kelvin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [26] Technical Note: Simulation of 4DCT tumor motion measurement errors
    Dou, Tai H.
    Thomas, David H.
    O'Connell, Dylan
    Bradley, Jeffrey D.
    Lamb, James M.
    Low, Daniel A.
    MEDICAL PHYSICS, 2015, 42 (10) : 6084 - 6089
  • [27] THE SIMULATION OF A BUILT-UP-TYPE DEFORMABLE PHANTOM FOR 4DCT
    Lee, Hea Jin
    Lee, Hyuk Jin
    Kim, Ji Na
    Kang, Young Nam
    Koo, Ja Choon
    2016 13TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2016, : 93 - 95
  • [28] 4DCT and VMAT planning for lung patients with irregular breathing
    Sisson, N.
    Caines, R.
    Rowbottom, C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S498 - S498
  • [29] An Improved 4DCT Reconstruction Algorithm for Patients with Irregular Breathing
    Harnage, A.
    Ramsey, C.
    Ratner, M.
    Bowling, J.
    Pfeiffer, I.
    MEDICAL PHYSICS, 2022, 49 (06) : E706 - E706
  • [30] 4DCT联合呼吸管理对NSCLC SBRT治疗精度的影响
    祖国红
    孙美丽
    窦岩
    岳晨曦
    汪延明
    赵惠
    中国卫生标准管理, 2024, 15 (19) : 88 - 92