4DCT Simulation With Synchronized Contrast Injection in Liver SBRT Patients

被引:11
|
作者
Helou, Joelle [1 ,2 ]
Karotki, Aliaksandr [3 ]
Milot, Laurent [4 ]
Chu, William [1 ,2 ]
Erler, Darby [1 ]
Chung, Hans T. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Radiat Oncol, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Med Phys, Toronto, ON M4N 3M5, Canada
[4] Sunnybrook Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
liver; stereotactic body radiation therapy; 4DCT; contrast; simulation; RADIATION-THERAPY; METASTASES; DELINEATION; RESECTION; MOTION;
D O I
10.1177/1533034615572341
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Purpose: Delivering stereotactic body radiotherapy for liver metastases remains a challenge because of respiratory motion and poor visibility without intravenous contrast. The purpose of this article is to describe a novel and simple computed tomography (CT) simulation process of integrating timed intravenous contrast that could overcome the uncertainty of target delineation. Methods and Results: The simulation involves two 4-dimensional CT (4DCT) scans. The first scan only encompasses the immediate region of the tumor and surrounding tissue, which reduces the 4DCT scan time so that it can be optimally timed with intravenous contrast injection. The second 4DCT scan covers a larger volume and is used as the primary CT data set for dose calculation, as well as patient setup verification on the treatment unit. The combination of the two 4DCT scans allows us to optimally visualize liver metastases over all phases of the breathing cycle while simultaneously acquiring a long enough 4DCT data set that is suitable for planning and patient setup verification. Conclusion: This simulation technique allows for a better target definition when treating liver metastases, without being invasive.
引用
收藏
页码:55 / 59
页数:5
相关论文
共 50 条
  • [31] A multicentre QA study on 4DCT and IMRT/VMAT techniques for lung SBRT using a respiratory phantom
    Lambrecht, M.
    Sonke, J. J.
    Verheij, M.
    Hurkmans, C. W.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S286 - S287
  • [32] Displacement of Liver Cancer and Interested Structures During Respiration Detected by 4DCT and 3DCT
    Zhang, Y.
    Li, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S723 - S723
  • [33] COMPARISON OF FIDUCIAL MOTION IN LIVER STEREOTACTIC ABLATIVE RADIOTHERAPY (SABR) PATIENTS USING 4DCT, AND FLUOROSCOPY
    Rodgerson, Christine
    Tai, Isaac
    Cumayas, Christina
    Bergman, Alanah
    Karan, Tania
    Camborde, Marie-Laure
    Dunne, Emma
    RADIOTHERAPY AND ONCOLOGY, 2019, 139 : S9 - S9
  • [34] Determination of Optimized Phase Through Correlation Between 4DCT Analysis Indices in Lung 4D SBRT
    Heo, E. J.
    Kim, M. S.
    Park, C. G.
    Kim, K. H.
    Shim, J. B.
    Hwang, H.
    Lee, N. K.
    Park, Y. J.
    Kim, C. Y.
    Lee, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E541 - E541
  • [35] Feasibility of 4D CT simulation with synchronized intravenous contrast injection in hepatocellular carcinoma
    Gupta, Anil
    Kumar, Rishabh
    Yadav, Hanuman Prasad
    Sharma, Manik
    Kamal, Rose
    Thaper, Deepak
    Banik, Prabir
    Gupta, Shipra
    Saroha, Kartik
    Singh, Sandeep
    Sarin, Shiv Kumar
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (02) : 293 - 298
  • [36] Comparative Assessment of Liver Tumor Motion Using CineMRI Versus 4DCT
    Fernandes, A.
    Teo, B. K.
    Yin, L.
    Rosen, M.
    Plastaras, J. P.
    Ben-Josef, E.
    Metz, J. M.
    Apisarnthanarax, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S45 - S46
  • [37] A Comparison of the Performance of Radiomic Features From Free Breathing and 4DCT Scans in Predicting Disease Recurrence in Lung Cancer SBRT Patients
    Huynh, E.
    Coroller, T.
    Narayan, V.
    Agrawal, V.
    Romano, J.
    Franco, I.
    Hou, Y.
    Mak, R.
    Aerts, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3385 - 3385
  • [38] The effect of 4DCT vs. 3DCT simulation on the positioning accuracy for lung cancer radiotherapy
    Wang, Y.
    Yang, P.
    Liu, Y.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1668 - S1669
  • [39] On the Use of 4DCT Derived Composite CT Images in the Planning of Stereotactic Body Radiotherapy (SBRT) for Lung Tumors
    Chen, Z.
    Ye, J.
    Su, F.
    Kim, J.
    Picone, J.
    Kimmett, J.
    Carlson, D. J.
    Deng, J.
    Nath, R.
    Decker, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S857 - S857
  • [40] A prospective study to validate pulmonary blood mass changes on non-contrast 4DCT in pulmonary embolism patients
    Nair, Girish B.
    Al-Katib, Sayf
    Turner-Lawrence, Danielle
    Khasawneh, Majd
    Myziuk, Nicholas
    Guerrero, Thomas
    Podolsky, Robert
    Castillo, Edward
    CLINICAL IMAGING, 2021, 78 : 179 - 183