Individualized breathing trace quality assurance for lung radiotherapy patients undergoing 4DCT simulation

被引:1
|
作者
Rijken, James [1 ]
Hu, Yunfei [2 ]
Hiscoke, Kelvin [3 ]
机构
[1] Icon Canc Ctr, Windsor Gardens, SA, Australia
[2] Icon Canc Ctr, Gosford, NSW, Australia
[3] Icon Canc Ctr, Wellington, New Zealand
来源
关键词
4DCT; breathing trace; lung; RGSC; RPM; SABR; VXP; RESPIRATORY MOTION; TUMOR MOTION; PHASE; ARTIFACTS; POSITION; IMPACT; ERRORS; 4D-CT;
D O I
10.1002/acm2.13929
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
4DCT simulation is a popular solution for radiotherapy simulation of lung cancer patients as it allows the clinician to gain an appreciation for target motion during the patient breathing cycle. Resultant binning of images and production of the 4DCT dataset relies heavily on the recorded breathing trace; but quality assurance is not routinely performed on these and there lacks any substantial recommendations thereof.An application was created for Windows in C# that was able to analyze the VXP breathing trace files from Varian RPM/RGSC and quantify various metrics associated with the patient breathing cycle. This data was then used to consider errors in voluming of targets for several example cases in order to justify recommendations on quality assurance.For 281 real patient breathing traces from 4DCT simulation of lung targets, notable differences were found between RGSC and application calculations of phase data. For any new patient without individualized QA, the average marked phase calculation (which is used for 4DCT reconstruction) is only accurate to within 19% of the actual phases. The error in BPM within the scan due to breathing rate variation is 37%. The uncertainty in amplitude due to breathing variation is 34% in the mean. Phase uncertainty leads to misbinning which we have shown can lead to missing 66% of the target for gated treatment. Variation in inhalation/exhalation level leads to voluming errors which, without individualized QA, can be assumed to be 11% (PTV is smaller than actual).Without individualized quality assurance of patient breathing traces, large uncertainties have to be assumed for metrics of both phase and amplitude, leading to clinically significant uncertainties in treatment. It is recommended to perform individualized quality assurance as this provides the clinician with an accurate quantification of uncertainty for their patient.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] 4DCT and VMAT for lung patients with irregular breathing
    Caines, Rhydian
    Sisson, Naomi K.
    Rowbottom, Carl G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):
  • [2] 4DCT and VMAT planning for lung patients with irregular breathing
    Sisson, N.
    Caines, R.
    Rowbottom, C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S498 - S498
  • [3] A Comprehensive Quality Assurance Procedure for 4DCT Commissioning
    Polizzi, M.
    Kim, S.
    Rosu-Bubulac, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E706 - E706
  • [4] Quality assurance of 4DCT in the EORTC Lungtech trial on SBRT for patients with NSCLC
    Lambrecht, M.
    Sonke, J. J.
    Nestle, U.
    Peulen, H.
    Weber, D.
    Verheij, M.
    Hurkmans, C. W.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S532 - S533
  • [5] Functionality-optimised radiotherapy for lung cancer patients using 4DCT
    Quinet, A.
    Paquier, Z.
    Jourani, Y.
    Fernandes, P.
    Van Houtte, P.
    Van Geestel, D.
    Reynaert, N.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S130 - S132
  • [6] The effect of 4DCT vs. 3DCT simulation on the positioning accuracy for lung cancer radiotherapy
    Wang, Y.
    Yang, P.
    Liu, Y.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1668 - S1669
  • [7] 4DCT oesophageal tumour delineation in SCOPE2-how is radiotherapy quality assurance beneficial?
    Cox, S.
    Jones, G.
    Radhakrishna, G.
    Mukherjee, S.
    Hawkins, M.
    Crosby, T.
    Gwynne, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S608 - S608
  • [8] A Simulation Study of Tolerance of Breathing Amplitude Variations in Radiotherapy of Lung Cancer Using 4DCT and Time-Resolved 4DMRI
    Li, Guang
    Sehovic, Admir
    Xu, Lee
    Shukla, Pawas
    Zhang, Lei
    Zhou, Ying
    Wang, Ping
    Wu, Abraham
    Rimner, Andreas
    Zhang, Pengpeng
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [9] An Improved 4DCT Reconstruction Algorithm for Patients with Irregular Breathing
    Harnage, A.
    Ramsey, C.
    Ratner, M.
    Bowling, J.
    Pfeiffer, I.
    MEDICAL PHYSICS, 2022, 49 (06) : E706 - E706
  • [10] 4DCT and VMAT for lung patients with irregular breathing: Phase vs. amplitude binning
    Caines, R.
    Sisson, N.
    Rowbottom, C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S213 - S213