Individualized breathing trace quality assurance for lung radiotherapy patients undergoing 4DCT simulation

被引:1
|
作者
Rijken, James [1 ]
Hu, Yunfei [2 ]
Hiscoke, Kelvin [3 ]
机构
[1] Icon Canc Ctr, Windsor Gardens, SA, Australia
[2] Icon Canc Ctr, Gosford, NSW, Australia
[3] Icon Canc Ctr, Wellington, New Zealand
来源
关键词
4DCT; breathing trace; lung; RGSC; RPM; SABR; VXP; RESPIRATORY MOTION; TUMOR MOTION; PHASE; ARTIFACTS; POSITION; IMPACT; ERRORS; 4D-CT;
D O I
10.1002/acm2.13929
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
4DCT simulation is a popular solution for radiotherapy simulation of lung cancer patients as it allows the clinician to gain an appreciation for target motion during the patient breathing cycle. Resultant binning of images and production of the 4DCT dataset relies heavily on the recorded breathing trace; but quality assurance is not routinely performed on these and there lacks any substantial recommendations thereof.An application was created for Windows in C# that was able to analyze the VXP breathing trace files from Varian RPM/RGSC and quantify various metrics associated with the patient breathing cycle. This data was then used to consider errors in voluming of targets for several example cases in order to justify recommendations on quality assurance.For 281 real patient breathing traces from 4DCT simulation of lung targets, notable differences were found between RGSC and application calculations of phase data. For any new patient without individualized QA, the average marked phase calculation (which is used for 4DCT reconstruction) is only accurate to within 19% of the actual phases. The error in BPM within the scan due to breathing rate variation is 37%. The uncertainty in amplitude due to breathing variation is 34% in the mean. Phase uncertainty leads to misbinning which we have shown can lead to missing 66% of the target for gated treatment. Variation in inhalation/exhalation level leads to voluming errors which, without individualized QA, can be assumed to be 11% (PTV is smaller than actual).Without individualized quality assurance of patient breathing traces, large uncertainties have to be assumed for metrics of both phase and amplitude, leading to clinically significant uncertainties in treatment. It is recommended to perform individualized quality assurance as this provides the clinician with an accurate quantification of uncertainty for their patient.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Automatically identifying patients at risk of 4DCT artifacts via their breathing signal
    Schwarz, Annette
    Dickmann, Jannis
    Hofmann, Christian
    Wohlfahrt, Patrick
    Szkitsak, Juliane
    Arias-Vergara, Tomas
    Maier, Andreas
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3945 - S3947
  • [22] INFLUENCE OF BREATHING MOTION MAGNITUDE, FREQUENCY AND REGULARITY ON IMAGE QUALITY IN 4DCT SCANS
    Kofoed, I. M. L.
    Aznar, M.
    Nygaard, D. E.
    Persson, G.
    Feidenhans, R. K.
    Korreman, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S437 - S437
  • [23] Evaluating mobility for radiotherapy planning of lung tumors: A comparison of virtual fluoroscopy and 4DCT
    van der Geld, Ylanga G.
    Senan, Suresh
    van Soernsen de Koste, John R.
    van Tinteren, Harm
    Slotman, Ben J.
    Underberg, Rene W. M.
    Lagerwaard, Frank J.
    LUNG CANCER, 2006, 53 (01) : 31 - 37
  • [24] A comparison of helical and 4DCT derived treatment plans for lung stereotactic body radiotherapy
    Franks, K.
    Purdie, T.
    Bissonnette, J.
    Cho, J.
    Payne, D.
    Sun, A.
    Kane, G.
    Jaffray, D.
    Bezjak, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S492 - S492
  • [25] Practical Issues and Solutions in Reconstructing and Using 4DCT for Radiotherapy Planning of Lung Cancer
    Lu, W.
    Feigenberg, S.
    Yi, B.
    Lasio, G.
    Prado, K.
    D' Souza, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 218 - 219
  • [26] THE POSITION DIFFERENCE OF LIVER CANCER IN FREE-BREATHING CONDITION BETWEEN 3DCT AND 4DCT SIMULATION
    Zhang, Yingjie
    ANNALS OF ONCOLOGY, 2012, 23 : 57 - 57
  • [27] New tools and methodology for stereotactic body radiotherapy (SBRT) simulation using 4DCT
    Hampton, C. J.
    Kearns, W. T.
    Hinson, W. H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2474 - 2474
  • [28] Beyond Single-Cycle 4DCT: Maximum a Posteriori (MAP) Reconstruction-Based Binning-Free Multicycle 4DCT for Lung Radiotherapy
    Cheung, Y.
    Hinkle, J.
    Joshi, S.
    Sawant, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 195 - 196
  • [29] 4DCT simulation with synchronized contrast injection of liver SBRT patients
    Karotki, A.
    Milot, L.
    Chu, W.
    Karol, R.
    Erler, D.
    Chung, H. T.
    MEDICAL PHYSICS, 2014, 41 (08) : 10 - 10
  • [30] 4DCT Simulation With Synchronized Contrast Injection in Liver SBRT Patients
    Helou, Joelle
    Karotki, Aliaksandr
    Milot, Laurent
    Chu, William
    Erler, Darby
    Chung, Hans T.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (01) : 55 - 59