Corneal pachymetry mapping with high-speed optical coherence tomography

被引:195
|
作者
Li, Y
Shekhar, R
Huang, D
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH USA
[3] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH USA
关键词
D O I
10.1016/j.ophtha.2006.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To map corneal thickness before and after LASIK with optical coherence tomography (OCT). Design: Cross-sectional observational study. Participants: Forty-two eyes of 21 normal subjects undergoing LASIK. Methods: A high-speed (2000 axial scans/second) 1.3-mu m-wavelength corneal and anterior segment OCT prototype was used for corneal scanning. The scan pattern consisted of 10-mm radial lines on 8 meridians centered on the vertex reflection. The entire scan pattern of 1024 a-scans was acquired in 0.5 seconds. We developed automated computer processing for 3-dimensional corneal reconstruction and measurement. Corneal thickness was measured normal to the anterior surface and presented as color pachymetry maps and zonal statistics. The maps were divided into a central zone (< 2 mm) and 3 annular areas (pericentral, 2-5 mm; transitional, 5-7 mm; peripheral, 7-10 mm), which were further divided into quadrantal zones. The average, minimum, and maximum corneal thicknesses were computed for zones within the 7-mm diameter. Optical coherence tomography and ultrasound pachymetry were measured 3 times at the preoperative and 3-month postoperative visits. Reproducibility was assessed by the pooled standard deviations (SDs) of the repeated measurements. Main Outcome Measures: Optical coherence tomography pachymetric map and zonal statistic, and ultrasound pachymetry. Results: Before LASIK, central corneal thicknesses (CCTs) were 546.9 +/- 29.4 mu m (mean +/- SD) for OCT and 553.3 +/- 33.0 mu m for ultrasound. After LASIK, CCTs were 513.7 +/- 44.5 mu m for OCT and 498 +/- 46.6 mu m for ultrasound. Optical coherence tomography and ultrasound CCT were highly correlated (Pearson correlation r = 0.97 before LASIK and 0.98 afterwards). Optical coherence tomography CCT was slightly less than ultrasound CCT before surgery (mean difference, -6.4 mu m; 95% limits of agreement, -23.2 to 10.4 mu m) but slightly greater after LASIK (15.7 mu m; -1.6 to 33 mu m). These differences were statistically significant, but no more than the CCT measurement differences between ultrasound pachymeters. The reproducibility of the OCT zonal pachymetry averages was roughly 2 Am. Conclusions: High-speed OCT provided noncontact, rapid, reproducible pachymetric mapping over a wide area of the cornea. It is equivalent to ultrasound for CCT measurement before and after LASIK This technology could be valuable for planning keratorefractiveprocedures and diagnosis of corneal diseases.
引用
收藏
页码:792 / 799
页数:8
相关论文
共 50 条
  • [21] Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia
    Wang, JH
    Fonn, D
    Simpson, TL
    Jones, L
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) : 93 - 98
  • [22] Optical-thermal model verification by high-speed optical coherence tomography
    Barton, JK
    Rollins, A
    Yazdanfar, S
    Pfefer, TJ
    Westphal, V
    Izatt, JA
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICA APPLICATIONS V, 2001, 4251 : 174 - 182
  • [23] Mapping retinal thickness and macular edema by high-speed three-dimensional optical coherence tomography
    Zhou, QY
    Trost, PK
    Lo, PW
    Hitzenberger, CK
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 119 - 125
  • [24] High-speed full-range spectral-domain correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580
  • [25] Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
    Tang, Maolong
    Li, Yan
    Avila, Mariana
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11): : 1843 - 1850
  • [26] Assessment of corneal dynamics with high-speed swept source Optical Coherence Tomography combined with an air puff system
    Alonso-Caneiro, David
    Karnowski, Karol
    Kaluzny, Bartlomiej J.
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2011, 19 (15): : 14188 - 14199
  • [27] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754
  • [28] New technology for high-speed and high-resolution optical coherence tomography
    Fujimoto, JG
    Bouma, B
    Tearney, GJ
    Boppart, SA
    Pitris, C
    Southern, JF
    Brezinski, ME
    ADVANCES IN OPTICAL BIOPSY AND OPTICAL MAMMOGRAPHY, 1998, 838 : 95 - 107
  • [29] High-resolution High-speed Spectral Domain Optical Coherence Tomography
    Song, Cheol
    Ahn, MyoungKi
    Gweon, DaeGab
    Cho, HyungSuck
    ISOT: 2009 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES, 2009, : 11 - +
  • [30] High-Speed Polarization Sensitive Optical Coherence Tomography for Retinal Diagnostics
    Yin, Biwei
    Wang, Bingqing
    Vemishetty, Kalyanramu
    Nagle, Jim
    Liu, Shuang
    Wang, Tianyi
    Rylander, Henry G., III
    Milner, Thomas E.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213