Assessment of corneal dynamics with high-speed swept source Optical Coherence Tomography combined with an air puff system

被引:80
|
作者
Alonso-Caneiro, David [1 ,2 ]
Karnowski, Karol [1 ]
Kaluzny, Bartlomiej J. [3 ]
Kowalczyk, Andrzej [1 ]
Wojtkowski, Maciej [1 ]
机构
[1] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[2] Queensland Univ Technol, Contact Lens & Visual Opt Lab, Sch Optometry, Brisbane, Qld 4001, Australia
[3] Nicholas Copernicus Univ, Dept Ophthalmol, Coll Med, Bydgoszcz, Poland
来源
OPTICS EXPRESS | 2011年 / 19卷 / 15期
关键词
OCULAR RESPONSE ANALYZER; DOMAIN MODE-LOCKING; INTRAOCULAR-PRESSURE MEASUREMENT; IN-SITU KERATOMILEUSIS; BIOMECHANICAL PROPERTIES; ANTERIOR SEGMENT; REFRACTIVE SURGERY; CONTACT-LENS; SPECTRAL OCT; HUMAN EYE;
D O I
10.1364/OE.19.014188
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed. (C) 2011 Optical Society of America
引用
收藏
页码:14188 / 14199
页数:12
相关论文
共 50 条
  • [1] A New Detector for High-Speed Swept Source Optical Coherence Tomography
    Fathipour, V.
    Mohseni, H.
    [J]. INFRARED SENSORS, DEVICES, AND APPLICATIONS V, 2015, 9609
  • [2] Non-contact investigation of the corneal biomechanics with air-puff swept source optical coherence tomography
    Maczynska, Ewa
    Karnowski, Karol
    Kaluzny, Bartlomiej
    Grulkowski, Ireneusz
    Wojtkowski, Maciej
    [J]. INTERFEROMETRY XVIII, 2016, 9960
  • [3] DEVELOPMENT OF HIGH-SPEED SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY SYSTEM AT 1320 nm
    Wu, Tong
    Ding, Zhihua
    Chen, Minghui
    Xu, Lei
    Shi, Guohua
    Zhang, Yudong
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2009, 2 (01) : 117 - 122
  • [4] High-speed KTN optical beam deflector for swept-source optical coherence tomography
    Sasaki, Yuzo
    Okabe, Yuichi
    Ueno, Masahiro
    Sakamoto, Takashi
    Toyoda, Seiji
    Kobayashi, Junya
    Yagi, Shogo
    Naganuma, Kazunori
    [J]. 2013 IEEE 3RD CPMT SYMPOSIUM JAPAN (ICSJ 2013), 2013,
  • [5] Imaging of stratified media using high-speed swept source optical coherence tomography
    Reddikumar, Maddipatla
    Poddar, Raju
    [J]. CURRENT SCIENCE, 2018, 114 (02): : 374 - 377
  • [6] Normalization detection method for high-speed swept-source optical coherence tomography
    Moon, Sucbei
    Kim, Dug Young
    [J]. 2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 175 - 176
  • [7] High-speed optical coherence tomography of corneal opacities
    Khurana, Rahul N.
    Li, Yan
    Tang, Maolong
    Lai, Michael M.
    Huang, David
    [J]. OPHTHALMOLOGY, 2007, 114 (07) : 1278 - 1285
  • [8] High-speed optical coherence tomography of corneal pathologies
    Bhatnagar, P
    Chalita, MR
    Meisler, D
    Li, Y
    Netto, M
    Huang, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U132 - U132
  • [9] Three-dimensional high-speed optical coherence tomography system using KTN swept light source
    Okabe, Y.
    Ueno, M.
    Sasaki, Y.
    Sakamoto, T.
    Toyoda, S.
    Kobayashi, J.
    Sugawa, Y.
    Fukuda, A.
    Ohmi, M.
    [J]. ELECTRONICS LETTERS, 2013, 49 (16) : 981 - 982
  • [10] High-speed swept source optical coherence Doppler tomography for deep brain microvascular imaging
    Wei Chen
    Jiang You
    Xiaochun Gu
    Congwu Du
    Yingtian Pan
    [J]. Scientific Reports, 6