Assessment of corneal dynamics with high-speed swept source Optical Coherence Tomography combined with an air puff system

被引:80
|
作者
Alonso-Caneiro, David [1 ,2 ]
Karnowski, Karol [1 ]
Kaluzny, Bartlomiej J. [3 ]
Kowalczyk, Andrzej [1 ]
Wojtkowski, Maciej [1 ]
机构
[1] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[2] Queensland Univ Technol, Contact Lens & Visual Opt Lab, Sch Optometry, Brisbane, Qld 4001, Australia
[3] Nicholas Copernicus Univ, Dept Ophthalmol, Coll Med, Bydgoszcz, Poland
来源
OPTICS EXPRESS | 2011年 / 19卷 / 15期
关键词
OCULAR RESPONSE ANALYZER; DOMAIN MODE-LOCKING; INTRAOCULAR-PRESSURE MEASUREMENT; IN-SITU KERATOMILEUSIS; BIOMECHANICAL PROPERTIES; ANTERIOR SEGMENT; REFRACTIVE SURGERY; CONTACT-LENS; SPECTRAL OCT; HUMAN EYE;
D O I
10.1364/OE.19.014188
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed. (C) 2011 Optical Society of America
引用
收藏
页码:14188 / 14199
页数:12
相关论文
共 50 条
  • [21] Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography
    Azimi, Ehsan
    Liu, Bin
    Brezinski, Mark E.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [22] High-speed and stable endoscopic optical coherence tomography system
    Liu, Qin-Ying
    Tang, Yu-Guo
    Ouyang, Nan
    Li, Gui-Qin
    Li, Min
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2021, 29 (10): : 2340 - 2348
  • [23] Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography
    Ding, Xixia
    Wang, Qinmei
    Xiang, Linfeng
    Chang, Pingjun
    Huang, Shenghai
    Zhao, Yun-e
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (06) : 388 - +
  • [24] Cataractous mountain on the corneal horizon: Swept-source optical coherence tomography
    Choudhry, Netan
    Golding, John
    Rao, Rajesh C.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 1097 - 1097
  • [25] Utility of the Swept Source Optical Coherence Tomography for Measurements of Central Corneal Thickness
    Kim, Im Gyu
    Lee, Chong Eun
    Lee, Jun Seok
    Seo, Sam
    Lee, Kyoo Won
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1542 - 1548
  • [26] High axial resolution swept source for optical coherence tomography
    Cordes, A. H.
    Xavier, G. B.
    de Faria, G. Vilela
    von der Weid, J. P.
    [J]. ELECTRONICS LETTERS, 2010, 46 (01) : 27 - 28
  • [27] Concept for high speed vocal cord imaging with swept-source optical coherence tomography
    Zabic, Miroslav
    Sharifpourboushehri, Sara
    Mueller-Wirts, Lennart
    Benecke, Hannes
    Heisterkamp, Alexander
    Meyer, Heiko
    Ripken, Tammo
    [J]. OPTICAL IMAGING, THERAPEUTICS, AND ADVANCED TECHNOLOGY IN HEAD AND NECK SURGERY AND OTOLARYNGOLOGY 2019, 2019, 10853
  • [28] High Speed, Full Range Imaging with Harmonic Detection Swept Source Optical Coherence Tomography
    Huang, Chuanyong
    Massick, Steven M.
    Peterson, Kristen A.
    Vakhtin, Andrei B.
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [29] High-speed, swept-source optical coherence tomography: a 3-dimensional view of anterior chamber angle recession
    Kawana, Keisuke
    Yasuno, Yoshiaki
    Yatagai, Toyohiko
    Oshika, Tetsuro
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (06): : 684 - 685
  • [30] Three-Dimensional Morphology Study of Capsule in Pseudophakic Eyes with High-Speed Swept-Source Optical Coherence Tomography
    Ding Xixia
    Chang Pingjun
    Zhang Hongfang
    Giacomo, Savini
    Huang Jinhai
    Chu Feixue
    Yu A-yong
    Fang, Huang
    Huang Shenghai
    Lei, Lin
    Zhao Yun-e
    [J]. CURRENT EYE RESEARCH, 2019, 44 (06) : 607 - 613