Corneal pachymetry mapping with high-speed optical coherence tomography

被引:195
|
作者
Li, Y
Shekhar, R
Huang, D
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH USA
[3] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH USA
关键词
D O I
10.1016/j.ophtha.2006.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To map corneal thickness before and after LASIK with optical coherence tomography (OCT). Design: Cross-sectional observational study. Participants: Forty-two eyes of 21 normal subjects undergoing LASIK. Methods: A high-speed (2000 axial scans/second) 1.3-mu m-wavelength corneal and anterior segment OCT prototype was used for corneal scanning. The scan pattern consisted of 10-mm radial lines on 8 meridians centered on the vertex reflection. The entire scan pattern of 1024 a-scans was acquired in 0.5 seconds. We developed automated computer processing for 3-dimensional corneal reconstruction and measurement. Corneal thickness was measured normal to the anterior surface and presented as color pachymetry maps and zonal statistics. The maps were divided into a central zone (< 2 mm) and 3 annular areas (pericentral, 2-5 mm; transitional, 5-7 mm; peripheral, 7-10 mm), which were further divided into quadrantal zones. The average, minimum, and maximum corneal thicknesses were computed for zones within the 7-mm diameter. Optical coherence tomography and ultrasound pachymetry were measured 3 times at the preoperative and 3-month postoperative visits. Reproducibility was assessed by the pooled standard deviations (SDs) of the repeated measurements. Main Outcome Measures: Optical coherence tomography pachymetric map and zonal statistic, and ultrasound pachymetry. Results: Before LASIK, central corneal thicknesses (CCTs) were 546.9 +/- 29.4 mu m (mean +/- SD) for OCT and 553.3 +/- 33.0 mu m for ultrasound. After LASIK, CCTs were 513.7 +/- 44.5 mu m for OCT and 498 +/- 46.6 mu m for ultrasound. Optical coherence tomography and ultrasound CCT were highly correlated (Pearson correlation r = 0.97 before LASIK and 0.98 afterwards). Optical coherence tomography CCT was slightly less than ultrasound CCT before surgery (mean difference, -6.4 mu m; 95% limits of agreement, -23.2 to 10.4 mu m) but slightly greater after LASIK (15.7 mu m; -1.6 to 33 mu m). These differences were statistically significant, but no more than the CCT measurement differences between ultrasound pachymeters. The reproducibility of the OCT zonal pachymetry averages was roughly 2 Am. Conclusions: High-speed OCT provided noncontact, rapid, reproducible pachymetric mapping over a wide area of the cornea. It is equivalent to ultrasound for CCT measurement before and after LASIK This technology could be valuable for planning keratorefractiveprocedures and diagnosis of corneal diseases.
引用
收藏
页码:792 / 799
页数:8
相关论文
共 50 条
  • [31] HIGH-SPEED IN-VIVO RETINAL IMAGING WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    HEE, MR
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1729 - 1729
  • [32] Design of spectrometer for high-speed line field optical coherence tomography
    Kamal, Mohammad
    Narayanswamy, Sivakumar
    Packirisamy, Muthukumaran
    PHOTONICS NORTH 2011, 2011, 8007
  • [33] Automated anterior chamber biometry with high-speed optical coherence tomography
    Li, Y
    Chalita, MR
    Goldsmith, J
    Westphal, V
    Bower, BA
    Shekhar, R
    Rollins, AM
    Izatt, JA
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U285 - U285
  • [34] Anterior chamber cell grading with high-speed optical coherence tomography
    Lowder, CY
    Li, Y
    Perez, VL
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U118 - U118
  • [35] High-speed complete optical coherence tomography signal processing solution
    Deterre, Romain
    Khatibi, Rouzbeh
    De Montigny, Etienne
    Khalid, Muneeb
    HIGH-SPEED BIOMEDICAL IMAGING AND SPECTROSCOPY: TOWARD BIG DATA INSTRUMENTATION AND MANAGEMENT II, 2017, 10076
  • [36] Optical coherence tomography based on high-speed scanning MEMS mirror
    Jung, WY
    McCormick, DT
    Zhang, J
    Tien, NC
    Chen, ZP
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 342 - 348
  • [37] High-speed optical coherence tomography based on line-scanning
    Jin, X
    Liu, TG
    Wu, KJ
    Li, G
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 543 - 546
  • [38] Pachymetric map of kerotoconus eyes with high-speed optical coherence tomography
    Li, Y
    Shekhar, R
    Meisler, DM
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U132 - U132
  • [39] Current Technologies for High-Speed and Functional Imaging with Optical Coherence Tomography
    Leitgeb, Rainer A.
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 168, 2011, 168 : 109 - 192
  • [40] A New Detector for High-Speed Swept Source Optical Coherence Tomography
    Fathipour, V.
    Mohseni, H.
    INFRARED SENSORS, DEVICES, AND APPLICATIONS V, 2015, 9609