摘要
Beyond the conventional non-contact temperature measurement with ambient temperature compensation and our previous work of multi-sensors compensation, two compensation schemes are proposed and compared. An infrared radiation measurement module with several temperature sensors are built and calibrated with ambient compensation to investigate the dynamic temperature distribution under moving of module from one place to another. The new approach we proposed including the infrared radiation exchanges model between the target, sensor and the optical path thorough temperature monitoring and two fast temperature measurement schemes with dynamic compensation. After careful calibrations and verification of several experiment conditions, our models of two dynamic compensation schemes both show an excellent agreement with the measuring data. The experimental data of compensation scheme reach a stable reading value of target temperature down from 40 min to 2 min for the differential scheme compensation and 6 min for multi-sensors scheme compensation with temperature error around 0.2 degrees C.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] INFRARED NON-CONTACT TEMPERATURE-MEASUREMENT
    KALOS, G
    [J]. GLASS INDUSTRY, 1983, 64 (07): : 26 - 27
  • [2] Non-contact measurement of thermal conduction by infrared radiation calorimetry
    Hisano, K
    [J]. ICMWFST '96 - 1996 4TH INTERNATIONAL CONFERENCE ON MILLIMETER WAVE AND FAR INFRARED SCIENCE AND TECHNOLOGY, PROCEEDINGS, 1996, : 289 - 292
  • [3] Non-contact infrared temperature measurement using machine vision
    Zhong Fei
    Shi Tielin
    He Tao
    Zhong Yuning
    [J]. THIRD INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, PTS 1 AND 2, 2006, 6280
  • [4] Non-contact temperature measurement
    不详
    [J]. INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [5] Non-contact temperature field measurement of solids by infrared multispectral thermotransmittance
    Pradere, C.
    Ryu, M.
    Sommier, A.
    Romano, M.
    Kusiak, A.
    Battaglia, J. L.
    Batsale, J. C.
    Morikawa, J.
    [J]. JOURNAL OF APPLIED PHYSICS, 2017, 121 (08)
  • [6] Non-contact infrared thermometry temperature measurement for screening fever in children
    Ng, DK
    Chan, CH
    Lee, RS
    Leung, LC
    [J]. ANNALS OF TROPICAL PAEDIATRICS, 2005, 25 (04): : 267 - 275
  • [7] Non-contact temperature measurement by infrared pyrometer in high speed milling
    Yang, Guang
    Hou, Junzhan
    Zhou, Wei
    Zhu, Lei
    Duan, Hongjian
    [J]. MECHANICAL COMPONENTS AND CONTROL ENGINEERING III, 2014, 668-669 : 969 - +
  • [8] Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System
    Jovanovic, Ugljesa
    Mancic, Dragan
    Jovanovic, Igor
    Petrusic, Zoran
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (02) : 904 - 910
  • [9] Non-contact endoscopic temperature measurement
    Vilches, Sergio
    Ataman, Caglar
    Zappe, Hans
    [J]. OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233
  • [10] OPTIMUM ALGORITHM OF INFRARED DEFECTOSCOPY IN CASE OF NON-CONTACT TEMPERATURE-MEASUREMENT
    TIKHOMIROV, VA
    TROITSKII, IN
    [J]. SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1977, 13 (01): : 55 - 59