Non-contact endoscopic temperature measurement

被引:0
|
作者
Vilches, Sergio [1 ]
Ataman, Caglar [1 ]
Zappe, Hans [1 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, Gisela & Erwin Sick Lab Microopt, Freiburg, Germany
关键词
Endoscopy; fiber sensor; pyrometry; guided surgery; endoscopic sensors;
D O I
10.1117/12.2543062
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We demonstrate a pyrometric contactless temperature sensor using a flexible fused silica fiber of 360 mu m diameter for endoscopic/laparoscopic surgery equipment. The large bandwidth (up to several kilohertz), and the broad temperature range (from 35 degrees C to 250 degrees C) of the sensor can be instrumental for time-resolved analysis and control of laser ablation and electrothermal surgery procedures. Fused silica fibers, as opposed to dedicated MIR fibers, are non-degrading, low-cost and biocompatible. Through dual-band detection, we also demonstrate a ratio-pyrometric measurement scheme, which improves the detection of hot-spots, providing a helpful tool for focused thermal processes observed, for example, in pulsed laser ablation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Non-contact temperature measurement
    不详
    [J]. INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [2] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    [J]. MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [3] Reduction of uncertainty with non-contact measurement of temperature
    Zakharenko, V. A.
    Veprikova, Ya R.
    Ponomarev, D. B.
    [J]. XII INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE APPLIED MECHANICS AND SYSTEMS DYNAMICS, 2019, 1210
  • [4] INFRARED NON-CONTACT TEMPERATURE-MEASUREMENT
    KALOS, G
    [J]. GLASS INDUSTRY, 1983, 64 (07): : 26 - 27
  • [5] Non-contact temperature measurement in embedded applications
    Ibrahim, Dogan
    [J]. ELECTRONICS WORLD, 2017, 123 (1971): : 14 - 16
  • [6] Non-contact temperature measurement of semitransparent silicon wafers
    Ikeda, Yoshikazu
    Iuchi, Tohru
    [J]. 2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 3412 - +
  • [7] Non-contact temperature measurement systems for industrial processes
    Zimmerhackl, M
    Nagel, F
    Budzier, H
    Hofmann, G
    [J]. TECHNISCHES MESSEN, 1999, 66 (03): : 109 - 115
  • [8] New polaradiometric method for non-contact temperature measurement
    Abtahi, A
    Barmatz, M
    [J]. SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM (STAIF-96), PTS 1-3: 1ST CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; 1ST CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 2ND SPACECRAFT THERMAL CONTROL SYMPOSIUM; 13TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION - FUTURE SPACE AND EARTH SCIENCE MISSIONS - SPECIAL TOPIC; REMOTE SENSING FOR COMMERCIAL, CIVIL AND SCIENCE APPLICATIONS - SPECIAL TOPIC, 1996, (361): : 303 - 307
  • [9] Non-contact measurement of the temperature profile of PET preforms
    Saggin, Bortolino
    Tarabini, Marco
    Scaccabarozzi, Diego
    Cornolti, Luca
    Giberti, Hermes
    Moschioni, Giovanni
    [J]. MEASUREMENT, 2019, 133 : 412 - 420
  • [10] MEASUREMENT OF PROCESS VARIABLES IN SUGAR INDUSTRY: NON-CONTACT TEMPERATURE MEASUREMENT
    Kadlec, Karel
    [J]. LISTY CUKROVARNICKE A REPARSKE, 2016, 132 (9-10): : 303 - 307