Modelling and infrared radiation compensation for non-contact temperature measurement

被引:0
|
作者
Shen, Chih-Hsiung [1 ]
Chang, Tsung-Dai [1 ]
Chen, Shu-Jung [1 ]
机构
[1] Natl Changhua Univ Educ, Dept Mechatron Engn, 2 Shi Da Rd, Changhua, Taiwan
关键词
D O I
10.1088/1757-899X/383/1/012023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Beyond the conventional non-contact temperature measurement with ambient temperature compensation and our previous work of multi-sensors compensation, two compensation schemes are proposed and compared. An infrared radiation measurement module with several temperature sensors are built and calibrated with ambient compensation to investigate the dynamic temperature distribution under moving of module from one place to another. The new approach we proposed including the infrared radiation exchanges model between the target, sensor and the optical path thorough temperature monitoring and two fast temperature measurement schemes with dynamic compensation. After careful calibrations and verification of several experiment conditions, our models of two dynamic compensation schemes both show an excellent agreement with the measuring data. The experimental data of compensation scheme reach a stable reading value of target temperature down from 40 min to 2 min for the differential scheme compensation and 6 min for multi-sensors scheme compensation with temperature error around 0.2 degrees C.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Non-contact infrared temperature measurements in dry permafrost boreholes
    Junker, Ralf
    Grigoriev, Mikhail N.
    Kaul, Norbert
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2008, 113 (B4)
  • [32] MEASUREMENT OF PROCESS VARIABLES IN SUGAR INDUSTRY: NON-CONTACT TEMPERATURE MEASUREMENT
    Kadlec, Karel
    [J]. LISTY CUKROVARNICKE A REPARSKE, 2016, 132 (9-10): : 303 - 307
  • [33] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    [J]. 2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [34] A non-contact FBG vibration sensor with double differential temperature compensation
    Li, Tianliang
    Tan, Yuegang
    Zhou, Zude
    Zheng, Kai
    [J]. OPTICAL REVIEW, 2016, 23 (01) : 26 - 32
  • [35] A non-contact FBG vibration sensor with double differential temperature compensation
    Tianliang Li
    Yuegang Tan
    Zude Zhou
    Kai Zheng
    [J]. Optical Review, 2016, 23 : 26 - 32
  • [36] Design and Development of a Low Cost, Non-Contact Infrared Thermometer with Range Compensation
    Goh, Nicholas Wei-Jie
    Poh, Jun-Jie
    Yeo, Joshua Yi
    Aw, Benjamin Jun-Jie
    Lai, Szu Cheng
    Cheng, Jayce Jian Wei
    Tan, Christina Yuan Ling
    Gan, Samuel Ken-En
    [J]. SENSORS, 2021, 21 (11)
  • [37] Non-contact Radiative Temperature Measurement of an Object in a Closed Cavity
    Xu, Dawei
    Rueter, Dirk
    Himmel, Joerg
    Erni, Daniel
    Thelen, Klaus
    [J]. 2017 47TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2017, : 872 - 875
  • [38] Optical Metrological Errors in Non-Contact Temperature Measurement Applications
    Book, A.
    [J]. CFI-CERAMIC FORUM INTERNATIONAL, 2014, 91 (10): : E16 - +
  • [39] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    [J]. AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [40] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    [J]. CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32