Biophysical phenotyping of single cells using a differential multiconstriction microfluidic device with self-aligned 3D electrodes

被引:58
|
作者
Yang, Dahou [1 ]
Zhou, Ying [2 ]
Zhou, Yinning [1 ]
Han, Jongyoon [2 ,3 ,4 ]
Ai, Ye [1 ]
机构
[1] Singapore Univ Technol & Design, Pillar Engn Prod Dev, Singapore 487372, Singapore
[2] Singapore MIT Alliance Res & Technol SMART Ctr, BioSyst & Micromech IRG BioSyM, Singapore 138602, Singapore
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] MIT, Dept Biol Engn, 77 Massachusetts Ave, Cambridge, MA 02139 USA
来源
基金
新加坡国家研究基金会;
关键词
Biophysical cellular biomarker; Cell deformability; Electrical impedance spectroscopy; Microfluidic cytometry; Single cell analysis; CANCER-CELLS; CHARACTERIZING DEFORMABILITY; HIGH-THROUGHPUT; CLASSIFICATION; IMPEDANCE;
D O I
10.1016/j.bios.2019.03.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Precise measurement of mechanical and electrical properties of single cells can yield useful information on the physiological and pathological state of cells. In this work, we develop a differential multiconstriction microfluidic device with self-aligned 3D electrodes to simultaneously characterize the deformability, electrical impedance and relaxation index of single cells at a high throughput manner ( > 430 cell/min). Cells are pressure driven to flow through a series of sequential microfluidic constrictions, during which deformability, electrical impedance and relaxation index of single cells are extracted simultaneously from impedance spectroscopy measurements. Mechanical and electrical phenotyping of untreated, Cytochalasin B treated and N-Ethylmaleimide treated MCF-7 breast cancer cells demonstrate the ability of our system to distinguish different cell populations purely based on these biophysical properties. In addition, we quantify the classification of different cell types using a back propagation neural network. The trained neural network yields the classification accuracy of 87.8% (electrical impedance), 70.1% (deformability), 42.7% (relaxation index) and 93.3% (combination of electrical impedance, deformability and relaxation index) with high sensitivity (93.3%) and specificity (93.3%) for the test group. Furthermore, we have demonstrated the cell classification of a cell mixture using the presented biophysical phenotyping technique with the trained neural network, which is in quantitative agreement with the flow cytometric analysis using fluorescent labels. The developed concurrent electrical and mechanical phenotyping provide great potential for high-throughput and label-free single cell analysis.
引用
收藏
页码:16 / 23
页数:8
相关论文
共 50 条
  • [21] Self-aligned molding technology (SAMT) for fabrication of 3D structures with a foldable imprint mold
    Smolarczyk, Marek
    Jablonka, Lukas
    Reuter, Sabrina
    Hillmer, Hartmut
    APPLIED NANOSCIENCE, 2019, 9 (06) : 1255 - 1263
  • [22] Self-aligned metallization on organic semiconductor through 3D dual-layer thermal nanoimprint
    Jung, Y.
    Cheng, X.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (09)
  • [23] A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells
    Shinha, Kenta
    Nihei, Wataru
    Kimura, Hiroshi
    MICROMACHINES, 2020, 11 (07)
  • [24] 3-D Self-Aligned Stacked Ge Nanowire pGAAFET on Si nFinFET of Single Gate CFET
    Lin, Yi-Wen
    Lin, Shan-Wen
    Chen, Bo-An
    Sun, Chong-Jhe
    Yan, Siao-Cheng
    Luo, Guang-Li
    Wu, Yung-Chun
    Hou, Fu-Ju
    IEEE JOURNAL OF THE ELECTRON DEVICES SOCIETY, 2023, 11 : 480 - 484
  • [25] Single-layer microfluidic device to realize hydrodynamic 3D flow focusing
    Eluru, Gangadhar
    Julius, Lourdes Albina Nirupa
    Gorthi, Sai Siva
    LAB ON A CHIP, 2016, 16 (21) : 4133 - 4141
  • [26] 3D silicon betavoltaics microfabricated using a self-aligned process for 5 milliwatt/cc average, 5 year lifetime microbatteries
    Duggirala, Rajesh
    Tin, Steven
    Lal, Amit
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [27] Self-Aligned Crystallographic Multiplication of Nanoscale Silicon Wedges for High-Density Fabrication of 3D Nanodevices
    Berenschot, Erwin
    Tiggelaar, Roald M.
    Borgelink, Bjorn
    van Kampen, Chris
    Deenen, Cristian S.
    Pordeli, Yasser
    Witteveen, Haye
    Gardeniers, Han J. G. E.
    Tas, Niels R.
    ACS APPLIED NANO MATERIALS, 2022, 5 (10) : 15847 - 15854
  • [28] Continuous-flow focusing of microparticles using induced-charge electroosmosis in a microfluidic device with 3D AgPDMS electrodes
    Jia, Yankai
    Ren, Yukun
    Jiang, Hongyuan
    RSC ADVANCES, 2015, 5 (82): : 66602 - 66610
  • [29] Self-aligned TiOx-based 3D vertical memristor for a high-density synaptic array
    Lee, Subaek
    Kim, Juri
    Kim, Sungjun
    FRONTIERS OF PHYSICS, 2024, 19 (06)
  • [30] Self-aligned 3D shadow-mask technique for patterning deeply recessed surfaces of MEMS devices
    Brugger, J
    Andreoli, C
    Despont, M
    Drechsler, U
    Rothuizen, H
    Vettiger, P
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 19 - 22