Photochemical micro-digestion in a multi-pumping flow system for phosphorus fractionation in cereals

被引:19
|
作者
Rocha, Diogo L. [1 ]
Rocha, Fabio R. P. [2 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05599970 Sao Paulo, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Multicommutation; Multi-pumping; Photo-conversion; Fractionation; Phosphorus; Cereals; NATURAL-WATERS; PHYTIC ACID; ORTHOPHOSPHATE; DECOMPOSITION;
D O I
10.1016/j.microc.2012.03.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drawbacks of sample preparation can be overcome by mechanization, minimizing systematic errors and analysis time, as well as improving precision. Multi-pumping flow systems (MPFS) attain the requirements for mechanization in a versatile and robust way, minimizing reagent consumption and waste generation. A MPFS was proposed for the fractionation of water soluble phosphorus in cereals, which is important because the bioavailability of this nutrient depends on its chemical form. Besides, phytic acid yields stable complexes with some micronutrients (e.g. Fe3+, Ca2+ and Mg2+), thus also altering their bioavailability. The flow system incorporated on-line photochemical conversion of organic phosphorus to phosphate, which was quantified by the spectrophotometric molybdenum blue method. A linear response was observed between 5 and 40 mg L-1 for both inorganic (P-I) and organic (P-O) phosphorus, with detection limits of 0.5 and 12 mg L-1, respectively. Coefficients of variation (n = 20) were estimated as 12 and 3.6% for P-I and P-O, respectively, with a sampling rate of 80 determinations per hour. Per determination, 380 mu g of (NH4)(8)Mo2O24, 620 mu g of ascorbic acid and 790 mu g of K2S2O8 were consumed, generating only 2.5 mL of waste. Interferences of organic matter were avoided by sample pretreatment with active charcoal (20 mg/mL). The results for cereal samples agreed with those obtained by the reference procedure based on nitro-percloric digestion. The proposed procedure is then a reliable, fast, inexpensive and more environmentally friendly alternative for phosphorus fractionation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [31] Simultaneous chemiluminometric determination of levodopa and benserazide in a multi-pumping flow system with multivariate calibration
    Marques, Karine L.
    Santos, Joao L. M.
    Lopes, Joao A.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2008, 24 (08) : 985 - 991
  • [32] A Multi-Pumping Flow System with Pulsed Fluidization to Evaluate Soil Capacity for Phosphate Adsorption
    Machado, Jeane M. C.
    Melchert, Wanessa R.
    Zagatto, Elias A. G.
    Kamogawa, Marcos Y.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (07) : 1149 - 1157
  • [33] Automatic Multi-pumping Flow System for the Chemiluminometric Screening of Scavenging Capacity against Singlet Oxygen
    Silva, Ana F. T.
    Marques, Karine L.
    Santos, Joao L. M.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2011, 27 (08) : 827 - 832
  • [34] Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron
    Pons, C
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) : 33 - 39
  • [35] Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water
    Gonzalez, Pablo
    Sixto, Alexandra
    Knochen, Moises
    TALANTA, 2017, 166 : 399 - 404
  • [36] An Automated Multi-Pumping Pulsed Flow System with Spectrophotometric Detection for the Determination of Phosphate in Natural Waters
    Ribeiro, Marta F. T.
    Couto, Cristina M. C. M.
    Conceicao, Pedro M. M.
    Santos, Joao L. M.
    ANALYTICAL LETTERS, 2013, 46 (11) : 1769 - 1778
  • [37] Automatic Multi-pumping Flow System for the Chemiluminometric Screening of Scavenging Capacity against Singlet Oxygen
    Ana F. T. Silva
    Karine L. Marques
    João L. M. Santos
    José L. F. C. Lima
    Analytical Sciences, 2011, 27 : 827 - 832
  • [38] Double-beam photometric direct-injection detector for multi-pumping flow system
    Kalinowski, Slawomir
    Koronkiewicz, Stanislawa
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 258 : 146 - 155
  • [39] Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell
    Aline S. Silva
    Ildikó V. TóTH
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    Analytical Sciences, 2011, 27 : 1031 - 1036
  • [40] Determination of glyphosate in water samples by multi-pumping flow system coupled to a liquid waveguide capillary cell
    Instituto de Química, Universidade Estadual Paulista , P. O. Box 355, Araraquara CEP 14801-970, SP, Brazil
    不详
    Anal. Sci., 10 (1031-1036):