Photochemical micro-digestion in a multi-pumping flow system for phosphorus fractionation in cereals

被引:19
|
作者
Rocha, Diogo L. [1 ]
Rocha, Fabio R. P. [2 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05599970 Sao Paulo, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Multicommutation; Multi-pumping; Photo-conversion; Fractionation; Phosphorus; Cereals; NATURAL-WATERS; PHYTIC ACID; ORTHOPHOSPHATE; DECOMPOSITION;
D O I
10.1016/j.microc.2012.03.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drawbacks of sample preparation can be overcome by mechanization, minimizing systematic errors and analysis time, as well as improving precision. Multi-pumping flow systems (MPFS) attain the requirements for mechanization in a versatile and robust way, minimizing reagent consumption and waste generation. A MPFS was proposed for the fractionation of water soluble phosphorus in cereals, which is important because the bioavailability of this nutrient depends on its chemical form. Besides, phytic acid yields stable complexes with some micronutrients (e.g. Fe3+, Ca2+ and Mg2+), thus also altering their bioavailability. The flow system incorporated on-line photochemical conversion of organic phosphorus to phosphate, which was quantified by the spectrophotometric molybdenum blue method. A linear response was observed between 5 and 40 mg L-1 for both inorganic (P-I) and organic (P-O) phosphorus, with detection limits of 0.5 and 12 mg L-1, respectively. Coefficients of variation (n = 20) were estimated as 12 and 3.6% for P-I and P-O, respectively, with a sampling rate of 80 determinations per hour. Per determination, 380 mu g of (NH4)(8)Mo2O24, 620 mu g of ascorbic acid and 790 mu g of K2S2O8 were consumed, generating only 2.5 mL of waste. Interferences of organic matter were avoided by sample pretreatment with active charcoal (20 mg/mL). The results for cereal samples agreed with those obtained by the reference procedure based on nitro-percloric digestion. The proposed procedure is then a reliable, fast, inexpensive and more environmentally friendly alternative for phosphorus fractionation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [41] A multi-pumping flow system for chemiluminometric determination of ascorbic acid in powdered materials for preparation of fruit juices
    Pires, Cherrine K.
    Lavorante, Andre F.
    Marconi, Luciana M. T.
    Meneses, Silvia R. P.
    Zagatto, Elias A. G.
    MICROCHEMICAL JOURNAL, 2006, 83 (02) : 70 - 74
  • [42] Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell
    Silva, Aline S.
    Toth, Ildiko V.
    Pezza, Leonardo
    Pezza, Helena R.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2011, 27 (10) : 1031 - 1036
  • [43] Exploiting kinetic spectrophotometric determination of captopril, an angiotensin-converting enzyme inhibitor, in a multi-pumping flow system
    Prior, Joao A. V.
    Santos, Joao L. M.
    Lima, Jose L. F. C.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 183 - 187
  • [44] In situ monitoring of atmospheric nitrous acid based on multi-pumping flow system and liquid waveguide capillary cell
    Yuhan Liu
    Keding Lu
    Huabin Dong
    Xin Li
    Peng Cheng
    Qi Zou
    Yusheng Wu
    Xingang Liu
    Yuanhang Zhang
    Journal of Environmental Sciences , 2016, (05) : 273 - 284
  • [45] In situ monitoring of atmospheric nitrous acid based on multi-pumping flow system and liquid waveguide capillary cell
    Yuhan Liu
    Keding Lu
    Huabin Dong
    Xin Li
    Peng Cheng
    Qi Zou
    Yusheng Wu
    Xingang Liu
    Yuanhang Zhang
    Journal of Environmental Sciences, 2016, 43 (05) : 273 - 284
  • [46] In situ monitoring of atmospheric nitrous acid based on multi-pumping flow system and liquid waveguide capillary cell
    Liu, Yuhan
    Lu, Keding
    Dong, Huabin
    Li, Xin
    Cheng, Peng
    Zou, Qi
    Wu, Yusheng
    Liu, Xingang
    Zhang, Yuanhang
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2016, 43 : 273 - 284
  • [47] Application of direct-injection detector integrated with the multi-pumping flow system to photometric stop-flow determination of total iron
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    TALANTA, 2012, 96 : 68 - 74
  • [48] Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index
    Nalewajko-Sieliwoniuk, Edyta
    Iwanowicz, Magdalena
    Kalinowski, Slawomir
    Kojlo, Anatol
    ANALYTICA CHIMICA ACTA, 2016, 911 : 82 - 91
  • [49] An eco-friendly method for analysis of sulfonamides in water samples using a multi-pumping system
    Catelani, Tiago Augusto
    Castoldi, Karine
    Toth, Ildiko Vargane
    Machado Santos, Joao Luis
    Fontes da Costa Lima, Jose Luis
    Pezza, Leonardo
    Pezza, Helena Redigolo
    CANADIAN JOURNAL OF CHEMISTRY, 2016, 94 (10) : 812 - 817
  • [50] An improved sampling approach in multi-pumping flow systems applied to the spectrophotometric determination of glucose and fructose in syrups
    Carneiro, JMT
    Dias, ACB
    Zagatto, EAG
    Santos, JLM
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2005, 531 (02) : 279 - 284