Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron

被引:43
|
作者
Pons, C [1 ]
Forteza, R [1 ]
Cerdà, V [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca 07122, Illes Balears, Spain
关键词
multi-pumping flow system; solid-phase extraction; chelating disk; preconcentration; speciation;
D O I
10.1016/j.aca.2005.06.072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-pumping flow system (MPFS) for the spectrophotometric determination, solid-phase extraction (SPE) and speciation analysis of iron at a wide range of concentrations is proposed. Chelating (iminodiacetic groups) disks have been used as solid phase. A solenoid valve allows the deviation of the flow towards the chelating disk to carry out SPE procedures. The possibility to combine solenoid micro-pumps with solenoid valves increases the versatility of MPFS. Ammonium thiocyanate has been chosen as chromogenic reagent for Fe(HI). The determination of total iron is achieved by the on-line oxidation of iron(II) to iron(HI) with a hydrogen peroxide stream. A mass calibration was run within the range 0.01-1.75 mu g. The detection limit (3(Sb)/S) was 0.01 mu g. The repeatability (R.S.D.) was estimated as 1.6% after 10-fold processing of 2 ml of 0.5 mg l(-1) Fe solution. When SPE was not required, two linear calibration graph within the ranges 0.05-10 and 0.2-15 mg l(-1) for the determination of iron(III) and total iron, respectively, were obtained. The proposed procedure was validated by analysis of certified reference materials. The analytical features were compared with those obtained exploiting MSFIA. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [1] Automated Spectrophotometric Multi-Pumping Flow System for the Determination of Total Iron in Wine
    Andreu, Cristina
    Danchana, Kaewta
    Cerda, Victor
    ANALYTICAL LETTERS, 2020, 53 (17) : 2775 - 2783
  • [2] Chemiluminometric determination of captopril in a multi-pumping flow system
    Rodrigues, S. Sofia M.
    Santos, Joao L. M.
    TALANTA, 2012, 96 : 210 - 215
  • [3] Multi-pumping flow system for spectrophotometric determination of bromhexine
    Dias, ACB
    Santos, JLM
    Lima, JLFC
    Zagatto, EAG
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 107 - 113
  • [4] Chemiluminometric determination of carvedilol in a multi-pumping flow system
    Pires, CK
    Marques, KL
    Santos, JLM
    Lapa, RAS
    Lima, JLFC
    Zagatto, EAG
    TALANTA, 2005, 68 (02) : 239 - 244
  • [5] A catalytic multi-pumping flow system for the chemiluminometric determination of metformin
    Karine L. Marques
    João L. M. Santos
    José L. F. C. Lima
    Analytical and Bioanalytical Chemistry, 2005, 382 : 452 - 457
  • [6] Determination of ambroxol in an automated multi-pumping pulsed flow system
    Santos, JLM
    Clausse, A
    Lima, JLRC
    Saraiva, MLMFS
    Rangel, AS
    ANALYTICAL SCIENCES, 2005, 21 (04) : 461 - 464
  • [7] A Multi-pumping Flow System for Fast Spectrophotometric Determination of Simvastatin
    Melchert, Wanessa R.
    Batista, Alex D.
    Pereira, Andreia C.
    Rocha, Diogo L.
    Rocha, Fabio R. P.
    CURRENT PHARMACEUTICAL ANALYSIS, 2013, 9 (01) : 114 - 120
  • [8] Determination of Ambroxol in an Automated Multi-Pumping Pulsed Flow System
    João L. M. Santos
    Arnaud Clausse
    José L. F. C. Lima
    M. L. M. F. S. Saraiva
    António O. S. Rangel
    Analytical Sciences, 2005, 21 : 461 - 464
  • [9] A multi-pumping flow system for spectrophotometric determination of oxalate in tea
    Rocha, Diego P.
    Pinto, Gabriel F.
    Silva, Sarah M.
    Squissato, Andre L.
    Silva, Sidnei G.
    MICROCHEMICAL JOURNAL, 2020, 157
  • [10] A catalytic multi-pumping flow system for the chemiluminometric determination of metformin
    Marques, KL
    Santos, JLM
    Lima, JLFC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) : 452 - 457