Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron

被引:43
|
作者
Pons, C [1 ]
Forteza, R [1 ]
Cerdà, V [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca 07122, Illes Balears, Spain
关键词
multi-pumping flow system; solid-phase extraction; chelating disk; preconcentration; speciation;
D O I
10.1016/j.aca.2005.06.072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-pumping flow system (MPFS) for the spectrophotometric determination, solid-phase extraction (SPE) and speciation analysis of iron at a wide range of concentrations is proposed. Chelating (iminodiacetic groups) disks have been used as solid phase. A solenoid valve allows the deviation of the flow towards the chelating disk to carry out SPE procedures. The possibility to combine solenoid micro-pumps with solenoid valves increases the versatility of MPFS. Ammonium thiocyanate has been chosen as chromogenic reagent for Fe(HI). The determination of total iron is achieved by the on-line oxidation of iron(II) to iron(HI) with a hydrogen peroxide stream. A mass calibration was run within the range 0.01-1.75 mu g. The detection limit (3(Sb)/S) was 0.01 mu g. The repeatability (R.S.D.) was estimated as 1.6% after 10-fold processing of 2 ml of 0.5 mg l(-1) Fe solution. When SPE was not required, two linear calibration graph within the ranges 0.05-10 and 0.2-15 mg l(-1) for the determination of iron(III) and total iron, respectively, were obtained. The proposed procedure was validated by analysis of certified reference materials. The analytical features were compared with those obtained exploiting MSFIA. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [21] Simultaneous chemiluminometric determination of levodopa and benserazide in a multi-pumping flow system with multivariate calibration
    Marques, Karine L.
    Santos, Joao L. M.
    Lopes, Joao A.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2008, 24 (08) : 985 - 991
  • [22] Polymeric Materials in Speciation Analysis Based on Solid-Phase Extraction
    Dakova, Ivanka
    Yordanova, Tanya
    Karadjova, Irina
    MOLECULES, 2024, 29 (01):
  • [23] Application of direct-injection detector integrated with the multi-pumping flow system to photometric stop-flow determination of total iron
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    TALANTA, 2012, 96 : 68 - 74
  • [24] Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water
    Gonzalez, Pablo
    Sixto, Alexandra
    Knochen, Moises
    TALANTA, 2017, 166 : 399 - 404
  • [25] Application of solid-phase extraction in metal speciation
    Urasa, IT
    Macha, SF
    ElMaaty, W
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (11) : 519 - 524
  • [26] Multi-pumping flow system for the determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples
    Pons, Carmen
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    Forteza, Rafael
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2006, 572 (01) : 148 - 154
  • [27] An Automated Multi-Pumping Pulsed Flow System with Spectrophotometric Detection for the Determination of Phosphate in Natural Waters
    Ribeiro, Marta F. T.
    Couto, Cristina M. C. M.
    Conceicao, Pedro M. M.
    Santos, Joao L. M.
    ANALYTICAL LETTERS, 2013, 46 (11) : 1769 - 1778
  • [28] Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell
    Aline S. Silva
    Ildikó V. TóTH
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    Analytical Sciences, 2011, 27 : 1031 - 1036
  • [29] Determination of glyphosate in water samples by multi-pumping flow system coupled to a liquid waveguide capillary cell
    Instituto de Química, Universidade Estadual Paulista , P. O. Box 355, Araraquara CEP 14801-970, SP, Brazil
    不详
    Anal. Sci., 10 (1031-1036):
  • [30] A multi-pumping flow system for chemiluminometric determination of ascorbic acid in powdered materials for preparation of fruit juices
    Pires, Cherrine K.
    Lavorante, Andre F.
    Marconi, Luciana M. T.
    Meneses, Silvia R. P.
    Zagatto, Elias A. G.
    MICROCHEMICAL JOURNAL, 2006, 83 (02) : 70 - 74