A Multi-pumping Flow System for Fast Spectrophotometric Determination of Simvastatin

被引:0
|
作者
Melchert, Wanessa R. [1 ]
Batista, Alex D. [2 ]
Pereira, Andreia C. [2 ]
Rocha, Diogo L. [3 ]
Rocha, Fabio R. P. [2 ]
机构
[1] Univ Sao Paulo, Escola Super Agr Luiz de Queiroz, Dept Ciencias Exatas Quim, BR-13418970 Piracicaba, SP, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Simvastatin; Flow analysis; Multicommutation; Multi-pumping; Spectrophotometry; MULTICOMMUTATION; BROMINE; ASSAY;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A flow-based system with solenoid micro-pumps is proposed for fast simvastatin (SMT) determination in pharmaceutical preparations. The method is based on the inhibition of methyl orange bromination in the presence of the analyte with spectrophotometric detection. A linear response was observed between 5.0 and 35 mg L-1 SMT with a detection limit of 1.2 mg L-1 (99.7% confidence level). The coefficient of variation (n = 20) and sampling rate were estimated as 3.3% and 80 determinations per hour, respectively. Reagents consumption was estimated as 3.5 mu g of NaBrO3, 9.5 mu g of methyl orange and 400 mu g of NaBr per determination, generating 4.5 mL of waste. The results for pharmaceutical samples agreed with those obtained by the reference chromatographic procedure at the 95% confidence level. The procedure is a fast, greener and reliable alternative for SMT determination.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] Multi-pumping flow system for spectrophotometric determination of bromhexine
    Dias, ACB
    Santos, JLM
    Lima, JLFC
    Zagatto, EAG
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 107 - 113
  • [2] A multi-pumping flow system for spectrophotometric determination of oxalate in tea
    Rocha, Diego P.
    Pinto, Gabriel F.
    Silva, Sarah M.
    Squissato, Andre L.
    Silva, Sidnei G.
    MICROCHEMICAL JOURNAL, 2020, 157
  • [3] Multi-pumping flow system for the spectrophotometric determination of dipyrone in pharmaceutical preparations
    Lima, JLFC
    Sá, SMO
    Santos, JLM
    Zagatto, EAG
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 1011 - 1017
  • [4] Automated Spectrophotometric Multi-Pumping Flow System for the Determination of Total Iron in Wine
    Andreu, Cristina
    Danchana, Kaewta
    Cerda, Victor
    ANALYTICAL LETTERS, 2020, 53 (17) : 2775 - 2783
  • [5] CIPROFLOXACIN AND NORFLOXACIN SPECTROPHOTOMETRIC DETERMINATION IN A FULLY AUTOMATED MULTI-PUMPING FLOW SYSTEM
    Amorim, M. Helena R.
    Marques, Karine L.
    Santos, Joao L. M.
    Lima, Jose L. F. C.
    ANALYTICAL LETTERS, 2011, 44 (12) : 2074 - 2084
  • [6] Spectrophotometric determination of phytic acid in plant extracts using a multi-pumping flow system
    Carneiro, JMT
    Zagatto, EAG
    Santos, JLM
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2002, 474 (1-2) : 161 - 166
  • [7] Chemiluminometric determination of captopril in a multi-pumping flow system
    Rodrigues, S. Sofia M.
    Santos, Joao L. M.
    TALANTA, 2012, 96 : 210 - 215
  • [8] Chemiluminometric determination of carvedilol in a multi-pumping flow system
    Pires, CK
    Marques, KL
    Santos, JLM
    Lapa, RAS
    Lima, JLFC
    Zagatto, EAG
    TALANTA, 2005, 68 (02) : 239 - 244
  • [9] An Automated Multi-Pumping Pulsed Flow System with Spectrophotometric Detection for the Determination of Phosphate in Natural Waters
    Ribeiro, Marta F. T.
    Couto, Cristina M. C. M.
    Conceicao, Pedro M. M.
    Santos, Joao L. M.
    ANALYTICAL LETTERS, 2013, 46 (11) : 1769 - 1778
  • [10] A catalytic multi-pumping flow system for the chemiluminometric determination of metformin
    Karine L. Marques
    João L. M. Santos
    José L. F. C. Lima
    Analytical and Bioanalytical Chemistry, 2005, 382 : 452 - 457