A Multi-pumping Flow System for Fast Spectrophotometric Determination of Simvastatin

被引:0
|
作者
Melchert, Wanessa R. [1 ]
Batista, Alex D. [2 ]
Pereira, Andreia C. [2 ]
Rocha, Diogo L. [3 ]
Rocha, Fabio R. P. [2 ]
机构
[1] Univ Sao Paulo, Escola Super Agr Luiz de Queiroz, Dept Ciencias Exatas Quim, BR-13418970 Piracicaba, SP, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Simvastatin; Flow analysis; Multicommutation; Multi-pumping; Spectrophotometry; MULTICOMMUTATION; BROMINE; ASSAY;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A flow-based system with solenoid micro-pumps is proposed for fast simvastatin (SMT) determination in pharmaceutical preparations. The method is based on the inhibition of methyl orange bromination in the presence of the analyte with spectrophotometric detection. A linear response was observed between 5.0 and 35 mg L-1 SMT with a detection limit of 1.2 mg L-1 (99.7% confidence level). The coefficient of variation (n = 20) and sampling rate were estimated as 3.3% and 80 determinations per hour, respectively. Reagents consumption was estimated as 3.5 mu g of NaBrO3, 9.5 mu g of methyl orange and 400 mu g of NaBr per determination, generating 4.5 mL of waste. The results for pharmaceutical samples agreed with those obtained by the reference chromatographic procedure at the 95% confidence level. The procedure is a fast, greener and reliable alternative for SMT determination.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [21] Simultaneous chemiluminometric determination of levodopa and benserazide in a multi-pumping flow system with multivariate calibration
    Marques, Karine L.
    Santos, Joao L. M.
    Lopes, Joao A.
    Lima, Jose L. F. C.
    ANALYTICAL SCIENCES, 2008, 24 (08) : 985 - 991
  • [22] A multi-pumping flow analysis system for β-galactosidase activity assays
    Skoczek, Justyna
    Pokrzywnicka, Marta
    Kubacka, Olga
    Koncki, Robert
    FOOD CHEMISTRY, 2019, 294 : 231 - 237
  • [23] Multi-pumping flow systems: The potential of simplicity
    Santos, Joao L. M.
    Ribeiro, Marta F. T.
    Dias, Ana C. B.
    Lima, Jose L. F. C.
    Zagatto, Elias E. A.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 21 - 28
  • [24] Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron
    Pons, C
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) : 33 - 39
  • [25] Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water
    Gonzalez, Pablo
    Sixto, Alexandra
    Knochen, Moises
    TALANTA, 2017, 166 : 399 - 404
  • [26] Multi-pumping flow system for the determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples
    Pons, Carmen
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    Forteza, Rafael
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2006, 572 (01) : 148 - 154
  • [27] Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell
    Aline S. Silva
    Ildikó V. TóTH
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    Analytical Sciences, 2011, 27 : 1031 - 1036
  • [28] Multi-pumping flow systems: an automation tool
    Lima, JLFC
    Santos, JLM
    Dias, ACB
    Ribeiro, MFT
    Zagatto, EAG
    TALANTA, 2004, 64 (05) : 1091 - 1098
  • [29] Determination of glyphosate in water samples by multi-pumping flow system coupled to a liquid waveguide capillary cell
    Instituto de Química, Universidade Estadual Paulista , P. O. Box 355, Araraquara CEP 14801-970, SP, Brazil
    不详
    Anal. Sci., 10 (1031-1036):
  • [30] A multi-pumping flow system for chemiluminometric determination of ascorbic acid in powdered materials for preparation of fruit juices
    Pires, Cherrine K.
    Lavorante, Andre F.
    Marconi, Luciana M. T.
    Meneses, Silvia R. P.
    Zagatto, Elias A. G.
    MICROCHEMICAL JOURNAL, 2006, 83 (02) : 70 - 74