Integrity of the stem-cement interface in THA: Effects of stem surface finish and cement porosity

被引:6
|
作者
Iesaka, Kazuho [1 ]
Jaffe, William L. [2 ]
Kummer, Frederick J. [2 ]
机构
[1] Manaka Mem Clin, Gunma 3700036, Japan
[2] New York Univ Hosp, Joint Dis Orthopaed Inst, Musculoskeletal Res Ctr, New York, NY 10003 USA
关键词
total hip replacement; bone cement; surface finish; cement porosity; stem preheating;
D O I
10.1002/jbm.b.31071
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
No consensus exists for the optimal surface finish on cemented total hip prosthesis stems. The purpose of this study was to determine the effects of stem finish and interfacial cement porosity on the integrity of the stem-cement interface. Simulated stems made of Co-Cr, having polished or matte surfaces, at room temperature or heated to 37 degrees C, were cemented into Sawbones simulated femurs. Push out testing of the stem-cement interface was performed immediately after cement polymerization and after two aging periods in 37 degrees C saline or 37 degrees C air, and the extent of interfacial porosity at the stem-cement interface was determined. Polished stems exhibited an average 60% greater interfacial strength than that of matte stems initially and up to 240% after aging treatments. Cement porosity at the stem-cement interface and incomplete cement interdigitation into surface asperities on matte stems likely allowed saline penetration into the stem-cement interface during wet aging, resulting in a rapid decrease of shear strength. Stem preheating to 37 degrees C virtually eliminated interfacial pores and resulted in greater shear strengths regardless of surface finish. Polished stem surfaces with stem preheating provided the best interfacial shear strength and sealing ability against saline penetration into the stem-cement interface and could result in increased longevity of stem fixation. (c) 2008 Wiley Periodicals, Inc.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [31] Results of in vitro studies about the mechanism of wear in the stem-cement interface of THR
    Wirz, D
    Zurfluh, B
    Göpfert, B
    Li, F
    Frick, W
    Morscher, EW
    STAINLESS STEELS FOR MEDICAL AND SURGICAL APPLICATIONS, 2003, 1438 : 222 - 234
  • [32] Experiment Investigation on Fretting Wear and Wear Debris Performance for the Stem-Cement Interface
    Zhang, Lanfeng
    Ge, Shirong
    Liu, Hongtao
    JOURNAL OF NANOMATERIALS, 2015, 2015
  • [33] The effects of cement-stem debonding in THA on the long-term failure probability of cement
    Verdonschot, N
    Huiskes, R
    JOURNAL OF BIOMECHANICS, 1997, 30 (08) : 795 - 802
  • [34] Modelling PMMA porosity on the cement-stem interface of hip implants
    Gould, Greg
    Goswami, Tarun
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2013, 11 (02) : 107 - 123
  • [35] Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding
    Verdonschot, N
    Tanck, E
    Huiskes, R
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 42 (04): : 554 - 559
  • [36] Novel methods to study functional loading micromechanics at the stem-cement and cement-bone interface in cemented femoral hip replacements
    Race, A.
    Miller, M. A.
    Mann, K. A.
    JOURNAL OF BIOMECHANICS, 2010, 43 (04) : 788 - 791
  • [37] THE LOAD CARRYING AND FATIGUE PROPERTIES OF THE STEM-CEMENT INTERFACE WITH SMOOTH AND POROUS COATED FEMORAL COMPONENTS
    MANLEY, MT
    STERN, LS
    GURTOWSKI, J
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (05): : 563 - 575
  • [38] 3D finite element analysis of stem-cement interface under cavity effect
    Amiri, R.
    Bouiadjra, B. Bachir
    Amiri, A.
    Haref, D. C.
    REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS, 2018, 28 (04): : 455 - 469
  • [39] Effect of the Residual Stresses at the Stem-Cement Interface on the Mechanical Behaviour of Cemented Hip Femoral Prosthesis
    Bouziane, M. M.
    Moulgada, A.
    Djebbara, N.
    Sahli, A.
    Bouiadjra, B. Bachir
    Benbarek, S.
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2015, 17 : 54 - 63
  • [40] Probabilistic analysis of the influence of the bonding degree of the stem-cement interface in the performance of cemented hip prostheses
    Perez, M. A.
    Grasa, J.
    Garcia-Aznar, J. M.
    Bea, J. A.
    Doblare, M.
    JOURNAL OF BIOMECHANICS, 2006, 39 (10) : 1859 - 1872