Percutaneous Transcatheter Mitral Valve Replacement First-in-Human Experience With a New Transseptal System

被引:72
|
作者
Webb, John G. [1 ]
Murdoch, Dale J. [1 ]
Boone, Robert H. [1 ]
Moss, Robert [1 ]
Attinger-Toller, Adrian [1 ]
Blanke, Philipp [1 ]
Cheung, Anson [1 ]
Hensey, Mark [1 ]
Leipsic, Jonathon [1 ]
Ong, Kevin [1 ]
Sathananthan, Janarthanan [1 ]
Wood, David A. [1 ]
Ye, Jian [1 ]
Tartara, Paolo [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Ctr Heart Valve Innovat, Vancouver, BC, Canada
关键词
mitral valve; transcatheter; TRIAL DESIGN PRINCIPLES; END-POINT DEFINITIONS; CONSENSUS DOCUMENT; REPAIR; REGURGITATION;
D O I
10.1016/j.jacc.2018.12.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Severe mitral regurgitation (MR) conveys significant morbidity and mortality, and surgical repair or replacement may not be a desirable option. OBJECTIVES The purpose of this study was to evaluate the feasibility of a percutaneous transseptal transcatheter mitral valve replacement (TMVR) system. METHODS This first-in-human study was conducted between August 2017 and August 2018. The system comprises a nitinol dock, which encircles the chordae tendineae, and a balloon-expandable transcatheter heart valve. The dock and transcatheter heart valve form an ensemble, with the native mitral valve leaflets secured in between, thereby abolishing MR. Key inclusion criteria were severe symptomatic MR and high surgical risk; exclusion criteria included left ventricular ejection fraction <30% or screening suggesting unfavorable anatomy. The primary endpoint was technical success as defined by Mitral Valve Academic Research Consortium (MVARC) criteria at completion of the index procedure. The secondary endpoint was freedom from mortality, stroke, and device dysfunction (MR grade > 1, mitral gradient > 6 mm Hg, left ventricular outflow tract gradient > 20 mm Hg) at 30 days. RESULTS Ten patients with severe MR of various etiologies (4 degenerative, 4 functional, and 2 mixed) were treated. The device was successfully implanted and the primary endpoint was achieved in 9 of 10 patients (90%). By transesophageal echocardiography, total MR was reduced to <= trivial in all implanted patients, and mean transmitral gradient was 2.3 +/- 1.4 mm Hg. A pericardial effusion occurred in 1 patient: pericardiocentesis was performed, and the device was not implanted. Median length of hospital stay was 1.5 days. At 30 days, there was no stroke, myocardial infarction, rehospitalization, left ventricular outflow tract obstruction, device migration, embolization, or conversion to mitral surgery. One patient had recurrent regurgitation due to a paravalvular leak, treated with a closure device. All other treated patients had <= 1+ MR. No patients died. CONCLUSIONS Percutaneous transvenous transseptal TMVR is feasible and safe in patients with severe MR who are at high risk for mitral valve surgery. Further evaluation is warranted. (J Am Coll Cardiol 2019; 73: 1239-46) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [41] Transseptal transcatheter mitral valve implantation versus redo surgical mitral valve replacement for degenerated mitral bioprostheses
    Fuchs, A.
    Lung, B.
    Nguyen, C.
    Carrasco, J. L.
    Cimadevilla, C.
    Kernels, C.
    Eugene, M.
    Ghodhbane, W.
    Ducrocq, G.
    Brochet, E.
    Provenchere, S.
    Vahanian, A.
    Himbert, D.
    Urena-Alcazar, M.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2633 - 2633
  • [42] Simultaneous Transapical Implantation of an Inverted Transcatheter Aortic Valve-in-Ring in the Mitral Position and Transcatheter Aortic Valve Replacement First-in-Human Report
    Ladeiras-Lopes, Ricardo
    Vouga, Luis
    Braga, Pedro
    Paulo, Nelson
    Azevedo, Ana Isabel
    Neves, Paulo
    Ribeiro, Jose
    Fonseca, Marlene
    Gama, Vasco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : E25 - E25
  • [43] Transcatheter transseptal mitral valve implantation with Edwards SAPIEN 3: the first experience of a single center
    Kralisz, Pawel
    Frank, Marek
    Sobkowicz, Bozena
    Dobrzycki, Slawomir
    Hirnle, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 105 - 108
  • [44] First-in-human: Transapical electrosurgical laceration and stabilization of mitral valve clips (ELASTA-CLIP) followed by transcatheter mitral valve replacement (TMVR)
    Kellermair, J.
    Damian, I
    Grund, M.
    Steinwender, C.
    Zierer, A.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S357 - S358
  • [45] SINGLE-CENTER EXPERIENCE IN TRANSCATHETER MITRAL VALVE REPLACEMENT WITH THE TENDYNE MITRAL VALVE SYSTEM
    Parlato, Alessandro
    Carapellucci, Eliana
    Mazzola, Matteo
    Vitale, Carlo
    Gentile, Francesco
    Spontoni, Paolo
    Giannini, Cristina
    Colli, Andrea
    De Carlo, Marco
    Petronio, Anna Sonia
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [46] International LAMPOON: first European experience with laceration of the anterior mitral valve leaflet prior to transseptal transcatheter mitral valve implantation
    Kasel, A. Markus
    Rumpf, Moritz
    Frangieh, Antonio H.
    Mayr, Patrick
    Joner, Michael
    Xhepa, Erion
    Lederman, Robert J.
    Greenbaum, Adam B.
    Khan, Jaffar M.
    Ott, Ilka
    Deutsch, Oliver
    Michel, Jonathan M.
    EUROINTERVENTION, 2018, 14 (07) : 746 - 749
  • [47] A step-by-step guide to transseptal valve-in-valve transcatheter mitral valve replacement
    Harloff, Morgan T.
    Chowdhury, Muntasir
    Hirji, Sameer A.
    Percy, Edward D.
    Yazdchi, Farhang
    Shim, Hunbo
    Malarczyk, Alexandra A.
    Sobieszczyk, Piotr S.
    Sabe, Ashraf A.
    Shah, Pinak B.
    Kaneko, Tsuyoshi
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (01) : 113 - 121
  • [48] Procedural performance and healing response of a novel lowprofile transseptal transcatheter mitral valve replacement system
    Ranard, Lauren S.
    Cheng, Yanping
    Yi, Genghua
    Ordanes, Diane
    McBride, Mitchell
    Butziger, John
    Forde, Sean
    Righini, Giovanni
    Denti, Paolo
    Vahl, Torsten P.
    EUROINTERVENTION, 2024, 20 (04) : e261 - e263
  • [49] First-in-Human Experience With Transcatheter Mitral Valve-in-Valve Implantation During Left Ventricular Assist Device Placement
    Orasanu, Gabriela
    Al-Kindi, Sadeer G.
    Robinson, Monique R.
    Oliveira, Guilherme H.
    Ginwalla, Mahazarin
    Elamm, Chantal
    Zacharias, Michael
    Farhoud, Mahmoud
    Medalion, Benjamin
    Deo, Salil V.
    Park, Soon J.
    Attizzani, Guilherme F.
    Sareyyupoglu, Basar
    CIRCULATION-HEART FAILURE, 2016, 9 (11)
  • [50] First-in-human transcatheter aortic valve-in-valve replacement with the SAPIEN 3 heart valve
    Mancio, Jennifer
    Almeida, Carla
    Pires-Morais, Gustavo
    Ferreira, Wilson
    Carvalho, Monica
    Rodrigues, Alberto
    Santos, Lino
    Melica, Bruno
    Oliveira, Marco
    Braga, Pedro
    Ribeiro, Vasco Gama
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 260 - 261