Percutaneous Transcatheter Mitral Valve Replacement First-in-Human Experience With a New Transseptal System

被引:72
|
作者
Webb, John G. [1 ]
Murdoch, Dale J. [1 ]
Boone, Robert H. [1 ]
Moss, Robert [1 ]
Attinger-Toller, Adrian [1 ]
Blanke, Philipp [1 ]
Cheung, Anson [1 ]
Hensey, Mark [1 ]
Leipsic, Jonathon [1 ]
Ong, Kevin [1 ]
Sathananthan, Janarthanan [1 ]
Wood, David A. [1 ]
Ye, Jian [1 ]
Tartara, Paolo [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Ctr Heart Valve Innovat, Vancouver, BC, Canada
关键词
mitral valve; transcatheter; TRIAL DESIGN PRINCIPLES; END-POINT DEFINITIONS; CONSENSUS DOCUMENT; REPAIR; REGURGITATION;
D O I
10.1016/j.jacc.2018.12.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Severe mitral regurgitation (MR) conveys significant morbidity and mortality, and surgical repair or replacement may not be a desirable option. OBJECTIVES The purpose of this study was to evaluate the feasibility of a percutaneous transseptal transcatheter mitral valve replacement (TMVR) system. METHODS This first-in-human study was conducted between August 2017 and August 2018. The system comprises a nitinol dock, which encircles the chordae tendineae, and a balloon-expandable transcatheter heart valve. The dock and transcatheter heart valve form an ensemble, with the native mitral valve leaflets secured in between, thereby abolishing MR. Key inclusion criteria were severe symptomatic MR and high surgical risk; exclusion criteria included left ventricular ejection fraction <30% or screening suggesting unfavorable anatomy. The primary endpoint was technical success as defined by Mitral Valve Academic Research Consortium (MVARC) criteria at completion of the index procedure. The secondary endpoint was freedom from mortality, stroke, and device dysfunction (MR grade > 1, mitral gradient > 6 mm Hg, left ventricular outflow tract gradient > 20 mm Hg) at 30 days. RESULTS Ten patients with severe MR of various etiologies (4 degenerative, 4 functional, and 2 mixed) were treated. The device was successfully implanted and the primary endpoint was achieved in 9 of 10 patients (90%). By transesophageal echocardiography, total MR was reduced to <= trivial in all implanted patients, and mean transmitral gradient was 2.3 +/- 1.4 mm Hg. A pericardial effusion occurred in 1 patient: pericardiocentesis was performed, and the device was not implanted. Median length of hospital stay was 1.5 days. At 30 days, there was no stroke, myocardial infarction, rehospitalization, left ventricular outflow tract obstruction, device migration, embolization, or conversion to mitral surgery. One patient had recurrent regurgitation due to a paravalvular leak, treated with a closure device. All other treated patients had <= 1+ MR. No patients died. CONCLUSIONS Percutaneous transvenous transseptal TMVR is feasible and safe in patients with severe MR who are at high risk for mitral valve surgery. Further evaluation is warranted. (J Am Coll Cardiol 2019; 73: 1239-46) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [21] Balloon Fracture of a Surgical Mitral Bioprosthesis During Valve-in-Valve Transcatheter Mitral Valve Replacement First-in-Human Report
    Kaneko, Tsuyoshi
    Piccirillo, Bryan
    Golwala, Harsh
    Trzcinka, Agnieszka
    Nyman, Charles
    Shook, Douglas
    Pelletier, Marc
    Berry, Natalia
    Sobieszczyk, Piotr
    Shah, Pinak
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (01)
  • [22] Transseptal Mitral Valve Replacement after Transcatheter Aortic Valve Implantation
    Flannery, Laura D.
    Lowery, Robert C., Jr.
    Sun, Xiumei
    Satler, Lowell
    Corso, Paul
    Pichard, Augusto
    Wang, Zuyue
    TEXAS HEART INSTITUTE JOURNAL, 2012, 39 (05) : 671 - 675
  • [23] First-in-human Results of the Novel Transcatheter Mitral Valve Repair System for Severe Mitral Regurgitation
    Lu, Zhi-Nan
    Ke, Yutong
    Bian, Yingnan
    He, Jing
    Wu, Wenhui
    Liu, Xinmin
    Li, Yang
    Liu, Ran
    Luo, Taiyang
    Guo, Xunan
    Song, Guangyuan
    CARDIOLOGY DISCOVERY, 2024, 4 (02): : 148 - 159
  • [24] Percutaneous Mitral Valve Replacement Using a Transvenous, Transseptal Approach Transvenous Mitral Valve Replacement
    Coylewright, Megan
    Cabalka, Allison K.
    Malouf, Joseph A.
    Geske, Jeffrey B.
    Pollak, Peter M.
    Suri, Rakesh M.
    Rihal, Charanjit S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (06) : 850 - 857
  • [25] Early Experience With New Transcatheter Mitral Valve Replacement
    Bapat, Vinayak
    Rajagopal, Vivek
    Meduri, Christopher
    Farivar, R. Saeid
    Walton, Antony
    Duffy, Stephen J.
    Gooley, Robert
    Almeida, Aubrey
    Reardon, Michael J.
    Kleiman, Neal S.
    Spargias, Konstantinos
    Pattakos, Stratis
    Ng, Martin K.
    Wilson, Michael
    Adams, David H.
    Leon, Martin
    Mack, Michael J.
    Chenoweth, Sharla
    Sorajja, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (01) : 12 - 21
  • [26] Transcatheter Mitral Valve Replacement After Transcatheter Electrosurgical Laceration of Alfieri STItCh (ELASTIC) First-in-Human Report
    Khan, Jaffar M.
    Lederman, Robert J.
    Sanon, Saurabh
    Leshnower, Bradley G.
    Yousef, Altayyeb
    Gleason, Patrick
    Lerakis, Stamatios
    Rogers, Toby
    Greenbaum, Adam B.
    Babaliaros, Vasilis C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08) : 808 - 811
  • [27] Percutaneous Closure of a Delayed Left Ventricular Pseudoaneurysm After Transseptal Transcatheter Mitral Valve Replacement
    Sawlani, Neal
    Berry, Natalia
    Sobieszczyk, Piotr
    Kaneko, Tsuyoshi
    Pelletier, Marc
    Shah, Pinak
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (14) : 1464 - +
  • [28] LAMPOON to Facilitate Tendyne Transcatheter Mitral Valve Replacement: From Animal Model to First-in-Human
    Khan, Jaffar
    Lederman, Robert
    Guyton, Robert
    Devireddy, Chandan
    Kamioka, Norihiko
    Yousef, Altayyeb
    Gleason, Patrick
    Babaliaros, Vasilis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B342 - B343
  • [29] Transcatheter mitral valve replacement with Tendyne: first experience in Spain
    Cobiella Carnicer, Javier
    Mahia Casado, Patricia
    Nombela-Franco, Luis
    Carnero Alcazar, Manuel
    Jimenez Quevedo, Pilar
    Maroto Castellanos, Luis Carlos
    REVISTA ESPANOLA DE CARDIOLOGIA, 2021, 74 (10): : 881 - 882
  • [30] Initial clinical experience with VersaCross transseptal system for transcatheter mitral valve repair
    Sayah, Neila
    Simon, Francois
    Garceau, Patrick
    Ducharme, Anique
    Basmadjian, Arsene
    Bouchard, Denis
    Pellerin, Michel
    Bonan, Raoul
    Asgar, Anita W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (06) : 1230 - 1234