Percutaneous Transcatheter Mitral Valve Replacement First-in-Human Experience With a New Transseptal System

被引:72
|
作者
Webb, John G. [1 ]
Murdoch, Dale J. [1 ]
Boone, Robert H. [1 ]
Moss, Robert [1 ]
Attinger-Toller, Adrian [1 ]
Blanke, Philipp [1 ]
Cheung, Anson [1 ]
Hensey, Mark [1 ]
Leipsic, Jonathon [1 ]
Ong, Kevin [1 ]
Sathananthan, Janarthanan [1 ]
Wood, David A. [1 ]
Ye, Jian [1 ]
Tartara, Paolo [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Ctr Heart Valve Innovat, Vancouver, BC, Canada
关键词
mitral valve; transcatheter; TRIAL DESIGN PRINCIPLES; END-POINT DEFINITIONS; CONSENSUS DOCUMENT; REPAIR; REGURGITATION;
D O I
10.1016/j.jacc.2018.12.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Severe mitral regurgitation (MR) conveys significant morbidity and mortality, and surgical repair or replacement may not be a desirable option. OBJECTIVES The purpose of this study was to evaluate the feasibility of a percutaneous transseptal transcatheter mitral valve replacement (TMVR) system. METHODS This first-in-human study was conducted between August 2017 and August 2018. The system comprises a nitinol dock, which encircles the chordae tendineae, and a balloon-expandable transcatheter heart valve. The dock and transcatheter heart valve form an ensemble, with the native mitral valve leaflets secured in between, thereby abolishing MR. Key inclusion criteria were severe symptomatic MR and high surgical risk; exclusion criteria included left ventricular ejection fraction <30% or screening suggesting unfavorable anatomy. The primary endpoint was technical success as defined by Mitral Valve Academic Research Consortium (MVARC) criteria at completion of the index procedure. The secondary endpoint was freedom from mortality, stroke, and device dysfunction (MR grade > 1, mitral gradient > 6 mm Hg, left ventricular outflow tract gradient > 20 mm Hg) at 30 days. RESULTS Ten patients with severe MR of various etiologies (4 degenerative, 4 functional, and 2 mixed) were treated. The device was successfully implanted and the primary endpoint was achieved in 9 of 10 patients (90%). By transesophageal echocardiography, total MR was reduced to <= trivial in all implanted patients, and mean transmitral gradient was 2.3 +/- 1.4 mm Hg. A pericardial effusion occurred in 1 patient: pericardiocentesis was performed, and the device was not implanted. Median length of hospital stay was 1.5 days. At 30 days, there was no stroke, myocardial infarction, rehospitalization, left ventricular outflow tract obstruction, device migration, embolization, or conversion to mitral surgery. One patient had recurrent regurgitation due to a paravalvular leak, treated with a closure device. All other treated patients had <= 1+ MR. No patients died. CONCLUSIONS Percutaneous transvenous transseptal TMVR is feasible and safe in patients with severe MR who are at high risk for mitral valve surgery. Further evaluation is warranted. (J Am Coll Cardiol 2019; 73: 1239-46) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [31] Transcatheter Aortic Valve Replacement With the St. Jude Medical Portico Valve First-in-Human Experience
    Willson, Alexander B.
    Rodes-Cabau, Josep
    Wood, David A.
    Leipsic, Jonathon
    Cheung, Anson
    Toggweiler, Stefan
    Binder, Ronald K.
    Freeman, Melanie
    DeLarochelliere, Robert
    Moss, Robert
    Nombela-Franco, Luis
    Dumont, Eric
    Szummer, Karolina
    Fontana, Gregory P.
    Makkar, Raj
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (07) : 581 - 586
  • [32] Impact of a Dedicated Transseptal Transcatheter Mitral Valve Replacement System on Cardiac Remodeling and Hemodynamics
    Coisne, Augustin
    Rodes-Cabau, Josep
    Ludwig, Sebastian
    Scotti, Andrea
    Mesnier, Jules
    Vahl, Torsten P.
    Ranard, Lauren S.
    Evans, Michael C.
    Modine, Thomas
    Granada, Juan F.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (10) : 1310 - 1312
  • [33] Addressing Anatomic Challenges to Transcatheter Mitral Valve Replacement With the Transseptal HighLife TMVR System
    Waggoner, Thomas
    Hussein, Ahmed
    Ehsan, Ariana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B401 - B401
  • [34] Transcatheter Tricuspid Valve Replacement With the EVOQUE System 1-Year Outcomes of a Multicenter, First-in-Human Experience
    Webb, John G.
    Chuang, Anthony
    Meier, David
    von Bardeleben, Ralph Stephan
    Kodali, Susheel K.
    Smith, Robert L.
    Hausleiter, Joerg
    Ong, Geraldine
    Boone, Robert
    Ruf, Tobias
    George, Isaac
    Szerlip, Molly
    Naebauer, Michael
    Ali, Faeez M.
    Moss, Robert
    Kreidel, Felix
    Bapat, Vinayak
    Schnitzler, Katharina
    Ye, Jian
    Wild, Mirjam
    Akodad, Mariama
    Deva, Djeven P.
    Chatfield, Andrew G.
    Mack, Michael J.
    Grayburn, Paul A.
    Peterson, Mark D.
    Makkar, Raj
    Leon, Martin B.
    Hahn, Rebecca T.
    Fam, Neil P.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (05) : 481 - 491
  • [35] Electrosurgical Laceration of Alfieri Stitch (ELASTIC) to Facilitate Transcatheter Mitral Valve Replacement: First-in-Human Report
    Khan, Jaffar
    Lederman, Robert
    Sanon, Saurabh
    Leshnower, Bradley
    Yousef, Altayyeb
    Gleason, Patrick
    Lerakis, Stamatios
    Rogers, Toby
    Greenbaum, Adam
    Babaliaros, Vasilis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B193 - B194
  • [36] Early experience with the Intrepid system for transcatheter mitral valve replacement
    Sorajja, Paul
    Bapat, Vinayak
    ANNALS OF CARDIOTHORACIC SURGERY, 2018, 7 (06) : 792 - 798
  • [37] Early Experience With the Innovalve Transcatheter Mitral Valve Replacement System
    Meerkin, David
    Guetta, Victor
    Shaburishvili, Tamaz
    Gogorishvili, Irakli
    Kipiani, Zviad
    Orlov, Boris
    Zirakashvili, Teona
    Bachilava, Natia
    Butnaru, Adi
    Goitein, Orly
    Raanani, Ehud
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (05) : 712 - 714
  • [38] Early experience of TIARA transcatheter mitral valve replacement system
    Cheung, Anson
    ANNALS OF CARDIOTHORACIC SURGERY, 2018, 7 (06) : 787 - 791
  • [39] Preoperative planning using virtual reality for percutaneous transseptal valve-in-valve transcatheter mitral valve replacement: a case report
    Castellanos, Jorge M.
    Barbery, Daniela
    Yefimov, Alex
    Dang, Phuong N.
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (10)
  • [40] A first-in-human study of transjugular transcatheter tricuspid valve replacement with the LuX-Valve Plus system
    Zhang, Yuan
    Lu, Fanglin
    Li, Wei
    Chen, Shasha
    Li, Mingfei
    Zhang, Xiaochun
    Pan, Cuizhen
    Qiao, Fan
    Zhou, Daxin
    Pan, Wenzhi
    Ge, Junbo
    EUROINTERVENTION, 2023, 18 (13) : E1088 - E1089