Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [1] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Shtin, T. N.
    Gurvich, V. B.
    Galasheva, O. E.
    Shelomentsev, I. G.
    Neudachina, L. K.
    Shtin, S. A.
    INORGANIC MATERIALS, 2023, 59 (14) : 1387 - 1395
  • [2] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    T. N. Shtin
    V. B. Gurvich
    O. E. Galasheva
    I. G. Shelomentsev
    L. K. Neudachina
    S. A. Shtin
    Inorganic Materials, 2023, 59 : 1387 - 1395
  • [3] Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Dravecz, Gabriella
    Bencs, Laszlo
    Beke, David
    Gali, Adam
    TALANTA, 2016, 147 : 271 - 275
  • [4] Three Advantages of High-Resolution Continuum Source Atomic Absorption Spectrometry
    Sun, Siqi
    SPECTROSCOPY, 2021, 36 (08) : 22 - 22
  • [5] High-Resolution Continuum Source Atomic and Molecular Absorption Spectrometry - A Review
    Welz, Bernhard
    Mores, Silvane
    Carasek, Eduardo
    Vale, Maria Goreti R.
    Okruss, Michael
    Becker-Ross, Helmut
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (05) : 327 - 354
  • [6] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    M. Yu. Burylin
    E. S. Kopeyko
    E. S. Kostyuchenko
    Journal of Analytical Chemistry, 2024, 79 : 310 - 317
  • [7] Determination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
    Krawczyk, Magdalena
    Matusiewicz, Henryk
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (05) : 749 - 757
  • [8] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Burylin, M. Yu.
    Kopeyko, E. S.
    Kostyuchenko, E. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (03) : 310 - 317
  • [9] Determination of Chlorine in Milk via Molecular Absorption of SrCI Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (28) : 5767 - 5772
  • [10] CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH HIGH-RESOLUTION AND WAVELENGTH MODULATION
    ZANDER, AT
    OHAVER, TC
    KELIHER, PN
    ANALYTICAL CHEMISTRY, 1976, 48 (08) : 1166 - 1175