The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures

被引:15
|
作者
Goldberg, Fernando [1 ]
Frajlich, Santiago [1 ]
Kuttler, Sergio [2 ]
Manzur, Emilio [1 ]
Briseno-Marroquin, Benjamin [3 ]
机构
[1] USAL AOA, Sch Dent, Dept Endodont, Buenos Aires, DF, Argentina
[2] Nova SE Univ, Coll Dent Med, Dept Endodont, Ft Lauderdale, FL 33314 USA
[3] Johannes Gutenberg Univ Mainz, Dept Operat Dent, Mainz, Germany
关键词
Apical limit; electronic apex locators; horizontal oblique root fracture;
D O I
10.1016/j.joen.2008.09.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n = 16) and 95% (n = 19) with the ProPex, 70% (n = 14) and 95% (n = 19) with the NovApex, 60% (n = 12) and 90% (n = 18) with the Root ZX, and 60% (n = 12) and 85% (n = 17) with the Elements Apex Locator when tolerances of 0.5-mm and 1.0-mm tolerance were, respectively, allowed. The analysis of variance (p > 0.05) and chi-square test (0.5 mm/p = 0.47 and 1.0 mm/p = 0.63 tolerances) showed no statistical significant differences between the EALs at either tolerance level. (J Endod 2008;34:1497-1499)
引用
收藏
页码:1497 / 1499
页数:3
相关论文
共 50 条
  • [31] Accuracy of Three Electronic Apex Locators in Anterior and Posterior Teeth: An Ex Vivo Study
    Mancini, Manuele
    Felici, Roberto
    Conte, Gabriele
    Costantini, Marco
    Cianconi, Luigi
    JOURNAL OF ENDODONTICS, 2011, 37 (05) : 684 - 687
  • [32] The accuracy of electronic apex locators for determining working length: An in vitro study with artificial teeth
    Bernardo, Raquel C. F. D.
    Alves, Louise S.
    Bruno, Adilia M., V
    Coutinho, Thais M. C.
    Gusman, Heloisa
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 217 - 221
  • [33] Accuracy of different electronic apex locators in determination of minimum Root perforation diameter
    Koc, Simay
    Kustarci, Alper
    Er, Kursat
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 : 179 - 186
  • [34] Effect of Prefllaring on Accuracy of Endodontic Length Determination by Four Electronic Apex Locators
    Izadi, Arash
    Bayandari, Maliheh
    Kazeminejad, Ezatolah
    JOURNAL OF DENTISTRY INDONESIA, 2022, 29 (03) : 165 - 171
  • [35] Effectiveness of four electronic apex locators to determine distance from the apical foramen
    Stoll, R.
    Urban-Klein, B.
    Roggendorf, M. J.
    Jablonski-Momeni, A.
    Strauch, K.
    Frankenberger, R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (09) : 808 - 817
  • [36] Evaluation of the accuracy of electronic apex locators, cone-beam computed tomography, and radiovisiography in primary teeth: An in vitro study
    Kayabasi, Mevlut
    Oznurhan, Fatih
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (11) : 1330 - 1335
  • [37] Effect of chloroform, orange solvent and eucalyptol on the accuracy of four electronic apex locators
    Al-Hadlaq, Solaiman M.
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 112 - 115
  • [38] Evaluation of the accuracy of three electronic apex locators using glass tubules
    Fan, W
    Fan, B
    Gutmann, JL
    Bian, Z
    Fan, MW
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (02) : 127 - 135
  • [39] Evaluation of the Accuracy of Electronic Apex Locators in Modern Endodontics: An Umbrella Review
    Pisano, Massimo
    Sangiovanni, Giuseppe
    Frucci, Eugenio
    Scorziello, Michela
    De Benedetto, Giuseppina
    Iandolo, Alfredo
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [40] Evaluation of Interference of Cellular Phones on Electronic Apex Locators: An In Vitro Study
    Sidhu, Preena
    Shankargouda, Swapnil
    Dicksit, Daniel DevaPrakash
    Mandey, Haydar Majeed
    Muzaffan, Danish
    Arora, Shelly
    JOURNAL OF ENDODONTICS, 2016, 42 (04) : 622 - 625