The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures

被引:15
|
作者
Goldberg, Fernando [1 ]
Frajlich, Santiago [1 ]
Kuttler, Sergio [2 ]
Manzur, Emilio [1 ]
Briseno-Marroquin, Benjamin [3 ]
机构
[1] USAL AOA, Sch Dent, Dept Endodont, Buenos Aires, DF, Argentina
[2] Nova SE Univ, Coll Dent Med, Dept Endodont, Ft Lauderdale, FL 33314 USA
[3] Johannes Gutenberg Univ Mainz, Dept Operat Dent, Mainz, Germany
关键词
Apical limit; electronic apex locators; horizontal oblique root fracture;
D O I
10.1016/j.joen.2008.09.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n = 16) and 95% (n = 19) with the ProPex, 70% (n = 14) and 95% (n = 19) with the NovApex, 60% (n = 12) and 90% (n = 18) with the Root ZX, and 60% (n = 12) and 85% (n = 17) with the Elements Apex Locator when tolerances of 0.5-mm and 1.0-mm tolerance were, respectively, allowed. The analysis of variance (p > 0.05) and chi-square test (0.5 mm/p = 0.47 and 1.0 mm/p = 0.63 tolerances) showed no statistical significant differences between the EALs at either tolerance level. (J Endod 2008;34:1497-1499)
引用
收藏
页码:1497 / 1499
页数:3
相关论文
共 50 条
  • [41] Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?
    Tekinarslan, Dide
    Erkal, Damla
    Ercan, Esen
    Koc, Simay
    Er, Kursat
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2024, 14 (03): : 727 - 732
  • [42] Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study
    Tosun, G.
    Erdemir, A.
    Eldeniz, A. U.
    Sermet, U.
    Sener, Y.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (05) : 436 - 441
  • [43] Horizontal root fractures in posterior teeth: a case series
    Wang, Ping
    Lv, Haipeng
    Sun, Hantang
    Lin, Yuan
    He, Wenxi
    DENTAL TRAUMATOLOGY, 2011, 27 (02) : 152 - 155
  • [44] Clinical evaluation of apical locators ROOT ZX and APEX FINDER 7005.
    Sá Neto, WC
    Fröner, IC
    Gurgel, ED
    De Deus, G
    Coutinho, T
    Maniglia-Ferreira, C
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 135 - 135
  • [45] Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination
    Ozata, Merve Yeniceri
    Falakaloglu, Seda
    Kaya, Sadullah
    MAKARA JOURNAL OF HEALTH RESEARCH, 2022, 26 (01): : 61 - 66
  • [46] Accuracy of an electronic apex locator in primary teeth with root resorption
    Angwaravong, O.
    Panitvisai, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (02) : 115 - 121
  • [47] Evaluation of the Root ZX Apex Locator in Primary Teeth
    Ghaemmaghami, Sara
    Eberle, Jason
    Duperon, Donald
    PEDIATRIC DENTISTRY, 2008, 30 (06) : 496 - 498
  • [48] Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study
    Moscoso, Saddy
    Pineda, Kenneth
    Basilio, Juan
    Alvarado, Carlos
    Roig, Miguel
    Duran-Sindreu, Fernando
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2014, 19 (02): : E202 - E205
  • [49] Accuracy of three different apex locators and visual exam in primary teeth with and without root resorption in vitro
    Oznurhan, F.
    Tuzuner, T.
    Baygin, O.
    Unal, M.
    Kapdan, A.
    Ozturk, C.
    EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 2014, 15 (04) : 381 - 384
  • [50] Ex vivo accuracy of three electronic apex locators:: Root ZX, elements diagnostic unit and apex locator and ProPex
    Plotino, G
    Grande, NM
    Brigante, L
    Lesti, B
    Somma, F
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (05) : 408 - 414