Risk of electromagnetic interference induced by dental equipment on cardiac implantable electrical devices

被引:5
|
作者
Miranda-Rius, Jaume [1 ]
Lahor-Soler, Eduard [1 ]
Brunet-Llobet, Lluis [2 ]
Sabate de la Cruz, Xavier [3 ]
机构
[1] Univ Barcelona, Fac Med & Ciencies Salut, Dept Odontostomatol, Feixa Llarga S-N, Barcelona 08907, Spain
[2] Univ Barcelona, Hosp St Joan de Deu, Serv Odontol, Barcelona, Spain
[3] Univ Barcelona, Fac Med & Ciencies Salut, Bellvitge Hosp, Serv Cardiol,Unitat Aritmies,Dept Ciencies Clin, Barcelona, Spain
关键词
dental equipment; electromagnetic interference; implantable cardioverter defibrillator; pacemaker; risk; CARDIOVERTER-DEFIBRILLATORS; PULP TESTERS; PART II; PACEMAKERS; CAPACITY;
D O I
10.1111/eos.12313
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Patients with cardiac implantable electrical devices should take special precautions when exposed to electromagnetic fields. Proximity to equipment used in clinical dentistry may cause interference. This study evaluated in vitro the risks associated with different types/makes of cardiac devices and types of dental equipment. Six electronic dental tools were tested on three implantable cardioverter defibrillators and three pacemakers made by different manufacturers. Overall, the risk of interference with the pacemakers was 37% lower than with the implantable cardioverter defibrillators. Regarding the types/makes of cardiac devices analysed, that from Boston Scientific had a five-fold greater risk of interference than did that from Biotronik [prevalence ratio (PR) = 5.58]; there was no difference between that from Biotronik and that from Medtronic. Among the dental equipment, the electric pulp tester had the greatest risk of inducing interference and therefore this device was used as the benchmark. The electronic apex locator (PR = 0.29), Periotest M (PR = 0.47), and the ultrasonic dental scaler (PR = 0.59) were less likely to induce interference than the electric pulp tester. The risk was lowest with the electronic apex locator. Pacemakers presented a lower risk of light to moderate interference (PR = 0.63). However, the risk of severe electromagnetic interference was 3.5 times higher with pacemakers than with implantable cardioverter defibrillators (PR = 3.47).
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [1] Electromagnetic interference effect of dental equipment on cardiac implantable electrical devices: A systematic review
    Niu, Yuting
    Chen, Yufei
    Li, Wenjing
    Xie, Ruiqin
    Deng, Xuliang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (12): : 1588 - 1598
  • [3] Capacity of dental equipment to interfere with cardiac implantable electrical devices
    Lahor-Soler, Eduard
    Miranda-Rius, Jaume
    Brunet-Llobet, Lluis
    Sabate de la Cruz, Xavier
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2015, 123 (03) : 194 - 201
  • [4] Electromagnetic interference of dental equipment with implantable cardioverter defibrillators
    de Sant'Anna Dadalti, Manoela Teixeira
    Ledo Alves da Cunha, Antonio Jose
    Pimenta de Araujo, Marcos Cesar
    Belo de Moraes, Luis Gustavo
    Risso, Patricia de Andrade
    ACTA ODONTOLOGICA SCANDINAVICA, 2017, 75 (08) : 584 - 587
  • [5] Suppression of Cautery-Induced Electromagnetic Interference of Cardiac Implantable Electrical Devices by Closely Spaced Bipolar Sensing
    Suresh, Mithun
    Benditt, David G.
    Gold, Barbara
    Joshi, Girish P.
    Lurie, Keith G.
    ANESTHESIA AND ANALGESIA, 2011, 112 (06): : 1358 - 1361
  • [6] Interference of electrical dental equipment with implantable cardioverter-defibrillators
    H. S. Brand
    M. L. Entjes
    A. V. Nieuw Amerongen
    E. V. van der Hoeff
    T. A. M. Schrama
    British Dental Journal, 2007, 203 : 577 - 579
  • [7] Interference of electrical dental equipment with implantable cardioverter-defibrillators
    Brand, H. S.
    Entjes, M. L.
    Amerongen, A. V. Nieuw
    Van der Hoeff, E. V.
    Schrama, T. A. M.
    BRITISH DENTAL JOURNAL, 2007, 203 (10) : 577 - 579
  • [8] Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
    Morava, Jan
    Richter, Ales
    Eichler, Jakub
    2019 PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MEASUREMENT (MEASUREMENT 2019), 2019, : 182 - 185
  • [9] Electromagnetic Interference with Cardiac Implantable Devices by Household and Industrial Appliances
    Yonemura, Tomohide
    Koyama, Junjiroh
    Sakai, Yoshirou
    Morinaga, Keiko
    Kurosaki, Ryousuke
    Araki, Yasuyuki
    Kawano, Yosin
    Nozoe, Masayoshi
    Tayama, Shinji
    Honda, Toshihiro
    Nakao, Koichi
    JOURNAL OF ARRHYTHMIA, 2011, 27 (01) : 49 - 56
  • [10] New test system to assess the risk of electromagnetic interference in cardiac active implantable medical devices
    Stunder, D.
    Kaiser, C.
    Silny, J.
    Joosten, S.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 857 - 857