Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [41] 99mTc-N, N′-bis(aminoethyl)propanediamine hexaacetic acid (BPHA):: a glomerular filtration agent similar to 99mTc-DTPA
    Liu, GZ
    Zhang, CL
    Liu, F
    Wang, RF
    Fu, ZL
    Li, GQ
    Miao, ZX
    NUCLEAR MEDICINE AND BIOLOGY, 2002, 29 (04) : 399 - 404
  • [42] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Kazuo Itoh
    Annals of Nuclear Medicine, 2003, 17 : 561 - 565
  • [43] Glomerular filtration rate can be estimated from the total bladder activity measured by quantitative 99mTc-DTPA SPECT-CT
    Kim, C.
    Cha, J.
    Kang, Y.
    Cha, D.
    Kang, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S516 - S516
  • [44] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [45] Development and Validation of Creatinine-Based Estimates of the Glomerular Filtration Rate Equation from 99mTc-DTPA Imaging in the Malaysian Setting
    Ralib, Azrina Md
    Hanafiah, Farah Nadia Mohd
    Abd Rashid, Iqbalmunawwir
    Abd Rahim, Mohamad Shahrir
    Dzaharudin, Fatimah
    Nor, Mohd Basri Mat
    INTERNATIONAL JOURNAL OF NEPHROLOGY, 2021, 2021
  • [46] Comparison of glomerular filtration rate estimation by 99mTc-DTPA to the reference radiotracer 51Cr-EDTA compared to methods based on blood creatinine measurement
    Saleh, N. S.
    Marie, S.
    Grimon, G.
    Durand, E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2021, 45 (03): : 142 - 146
  • [47] Glomerular filtration rate measured by 99mTc-DTPA Gates method is not significantly affected by the premature or delayed initiation of image acquisition.
    Ma, Guangyu
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [48] Determination of intestinal permeability by 99mTc-DTPA in protozoan infections
    Taner, MS
    Argon, M
    Köseoglu, K
    Dagci, H
    Üstün, S
    Budak, S
    Duman, Y
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1239 - 1239
  • [49] Quality Control of 99mTc-DTPA-Derived Glomerular Filtration Rate Studies using Multiple Plasma Samples
    Klein, Ran
    Memon, Rayhan
    Zuckier, Lionel
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [50] Clinical value of cystatin C and beta-trace protein in glomerular filtration rate in renal transplant cases with stable renal graft functions: comparison by the 99mTc-DTPA plasma sample method
    Oner, Ali Ozan
    Aydin, Funda
    Demirelli, Serkan
    Budak, Evrim S.
    Davran, Fatih
    Akbas, Halide
    Kocak, Huseyin
    Suleymanlar, Gultekin
    Gungor, Firat
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (07) : 733 - 744